Use the Listener Properties tab to configure listener processes that wait for JMS messages received from an external system. After you complete this tab and save the JMS Listener form, you can click the Test Connectivity button to confirm that you can connect to the JNDI server and then to the JMS producer identified.

Listener nodes

FieldDescription
Start Option Select to control how listeners start:
  • Run on all nodes — The listener is run on all nodes — all servers in a cluster.
  • Node based startup — The listener is started only on specified nodes.
  • Host based startup — The listener is started on a specified number of nodes on specific servers within the cluster.
  • NodeClassification based startup — The listener is started on the specified node types.
Node ID Appears when the Node based startup option is selected. In a multinode cluster, using the SmartPrompt, enter the node ID of the server host node or nodes where this listener will run. When your server starts, it activates the listener on the current node if the current node matches any node in the list (and if other requirements are met).
  • If a node is specified, the current node must match a name in the list to activate the listener.
  • If a node is not specified, the listener is activated on each node.

When multiple JMS listeners tend the same directory, the order in which messages are processed may not be the order in which they were put into the directory. If your application relies on processing messages in the order in which they are sent, use a single listener on one node.

See More about JMS Listeners.

Host Name Appears when the Server based startup option is selected. Enter the network location name of the host server on which the listener is to start.
Node Count Appears when the Server based startup option is selected. Enter a number of nodes on which the listener is to start.
Node type Appears when the NodeClassification based startup option is selected. Select a node type from the list or click the Plus icon to add another node type to the listener.
Reset Startup Deletes all the instances from the class Log-Connect-AssignedNodes, so that listeners can be started.

Listener properties

FieldDescription
Service Package Select the first key part — Customer Package Name — of the set of Service JMS rules ( Rule-Service-JMS rule type) that are to process arriving JMS messages. This listener ignores messages referencing other packages.
Service Class Optional. Select the second key part — Customer Class Name — of one or more Service JMS rules within the package identified. This listener ignores messages that reference other classes within the package.

If this field is blank, the listener uses the PegaRULES_ServiceClass property in the request message as the second key part.

Service Method Optional. Enter the third key part — Customer Method Name — of the Service JMS rule that will process the requests. This listener ignores messages that reference other methods within the Service Class and Service Package.

If this field is blank, the listener uses the PegaRULES_ServiceMethod property in the request message as the third key part.

Concurrent ThreadsIdentify the number of threads per server node that this listener creates when it starts.
Wait Interval (seconds)Enter an interval in seconds to specify how often the listener pauses to determine whether to stop. Enter zero if the listener is never to pause to determine whether it stops.
Send error messages? If selected, and a processing error occurs that is not handled by a configured response message, the listener sends or publishes an empty message that contains the error message in an application-specific JMS property.

Error messages can be sent only if the client application has set the JMSReplyTo header value in the request message. They are sent to the reply queue specified in that field.

This option is disabled if you select No Reply as the Preference on the JMS Properties tab.

Container Managed Transaction?

Used only for the condition described in the Pega Community article Using MQ and JMS services with Enterprise Application deployment.

Test Connectivity Optional. After you complete this tab and save the data instance, click to confirm that your system can connect to the JMS Producer Model data instance.

The system presents test results in a separate window, identifying the parameters used in the test, the steps attempted, and the outcome of each step. (This capability is available only when JMS JAR libraries are installed on the current node. If not, a Java exception is thrown.)

(If the Blocked check box is selected when you click this button, testing ends with a Failed message.)

Requestor log-in

FieldDescription
Requestor User IDOptional. Identify an Operator ID data instance that service requestors are to use, unless they can operate as unauthenticated guest requestors.
PasswordOptional. Enter a password for the service requestor.

Diagnostics

The remote logging feature streams the contents of the Pega log file to the LogFactor5 application installed on your workstation.

After you add your workstation as an active logger in Admin Studio, your workstation receives all messages for all processes running on the server. To view only those log messages that are about the service rule this listener listens for, complete the fields in this section. Remember to start the LogFactor5 application on your workstation before updating this form to identify your workstation as a logger.

Remote Host Optional. You can debug the listener using the remote logging feature. Enter the name of your workstation. See also How to install and use remote logging
PortOptional. Enter the TCP/IP port that the log4j package on your workstation listens on. By default this port is 8887.

Startup status

Blocked

Select to prevent this listener from being started by any means. If cleared, this listener starts with system startup, or can be started using the Listener Management menu item in the System Management application. See More about JMS Listeners.

  • Previous topic JMS Listener data instances - Completing the New or Save As form
  • Next topic JMS Listener form - Completing the JMS Properties tab

Have a question? Get answers now.

Visit the Support Center to ask questions, engage in discussions, share ideas, and help others.

Did you find this content helpful?

Want to help us improve this content?

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us