Skip to main content


         This documentation site is for previous versions. Visit our new documentation site for current releases.      
 

No data flow service nodes are available

Updated on May 17, 2024

The following exception occurs when you start processing a data flow run: No data flow service nodes available.

Cause

The data flow service is not configured. To configure a data flow service, you must add at least one decision data node on the Data Flow tab of the Services landing page.

Solution

  1. In the header of Dev Studio, click ConfigureDecisioningInfrastructureServicesData flow.
  2. Click Add node.
  3. Select a node to become a decision data node.
  4. Click Submit.
    The status of the new node is set to JOINING.
  5. Click Refresh to ensure that the status of the decision data node changes to NORMAL.
    Data Flow tab on the Services landing page
    The list contains a single node. The status of the node is normal.
  • Previous topic Failure or performance issues when saving records to the database
  • Next topic Troubleshooting Decision Data rules

Have a question? Get answers now.

Visit the Support Center to ask questions, engage in discussions, share ideas, and help others.

Did you find this content helpful?

Want to help us improve this content?

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us