Refresh-Other section correctly shifts focus on tab out

After upgrade, a difference was seen in the behavior of the Refresh-Other section action functions. Previously, focus was shifted to the next field when tabbing out, which is the desired behavior. Investigation showed that this was a result of modifications made to resolve other focus issues, and the previous behavior has been returned by updating the conditions used to call the "focusNextElement" method to include a check whether the reloadElement is stale, and to get the focusElement from DOM based on name (pega.util.Dom.getElementsByName(focusElemName)) if needed.

Case UI correct following multiple approval levels

After proceeding through different levels of approvals, the UI of the case was incorrect on the final approval submit. This was traced to the forceSkinGeneration parameter, which was set to true, being used by a workformstyles fragment. This has been resolved by changing pzUsePreferenceSkin to "once" and setting the parameter forceSkinGeneration to false after the pyAttachAsPDF activity call.

Case manager portal links working with SVG file

After modifying the pyPortalHeader to show a custom logo in the Case manager portal by saving the pyapp-logo.svg file into a ruleset and uploading the logo, none of the Case manager portal links or menus were working and a console error appeared. Investigation showed the SVG file stream was decoded and then encoded using the Base64Util.encode and decode, which was adding new line characters. To resolve this, step 4 in Rule-File-Binary.UploadFile Activity has been modified to remove the Base64 encode and decode.

Context-specific APIs used for RefreshHarness with AJAX container

After creating an interaction case and letting it go idle, attempting to continue and process the service cases in that case was intermittently resulting in a transaction ID mismatch error. This was traced to handling in the AJAX container, and has been resolved by updating the system to use context-specific APIs for refreshHarness case in doc_submit.

Support added for custom portal with temporary work object

After creating a screen flow with temporary work object in a custom portal, entering some data and clicking caused the screen to be blank after browser refresh. The same process from Designer Studio or the Case Manager portal worked as expected. Investigation showed that SPA applications with displayonpage actions was sending empty parameters to render the harness due to the 'doUiAction' activity clearing additional pages for single frame portals. To resolve this, the 'when' rule in step14 has been updated to support a custom portal and temporary work object.

Check added for unicode calendar values

After creating a repeating grid section for work report definition with enabled filter option, running the section and giving the filter value in unicode calendar form such as 2019/11/12 did not pass validation. This has been resolved by adding a check for unicode values

Reset focus to Rich-text editor after Spellchecker use

After correcting the misspelled words as suggested by SpellChecker, the corrected words were not reflected in the email. This was traced to a focus issue in Rich-text editor, and has been resolved by ensuring the focus is returned to Rich-text editor once the suggested corrections are accepted.

ArtifactoryStorage URL construction with port updated

After configuring a repository as a JFROG artifactory with a ruleform that provided a URL / port number and repository name, test connectivity worked as expected, but deploying the codeset using pipeline or importing the codeset using the import functionality generated the error "Unable to construct artifactory url due to invalid file path". The root cause of the issue was traced to the ArtifactoryStorage java class, which did not accept the port number in the format provided due to changes in the API. If there was no portNumber in the URL, the issue did not occur.

Corrected ReportBrowser refresh section

After bringing up the popup menu on a report shortcut in the report viewer and then dismissing it, the gear icon on the shortcuts in the upper section of the report browser stopped responding. This has been resolved by updating the system to refresh the pyReportBrowserInner section instead of pyReportBrowserAll.

Multiselect control support for offline-enabled iOS app

After a custom mobile application for iOS was built and was running on iPad for an offline-enabled user adding a multiselect control into a section as part a flow caused the screen to hang when a save or submit was performed. This has been resolved by enhancing support for offline multiselect submit with the addition of pzpega_ui_template_multiselect_capsule to offline static bundle.