Cumulative Build Notes: Pega Robotic Automation 7.1
Build notes describe the changes included within each build created for Pega® Robotic Automation Studio/Runtime version 7.1. Before you install one of these builds, familiarize yourself with the changes, new features, and resolved issues listed in the following table.
To request a build, contact your Support Representative. You can contact Support using the Pega Product Support portal. For information on system requirements, review your installation instructions:
- Pega Robotic Automation Studio 7.1 Installation Instructions
- Pega Robotic Automation Studio 7.1 Plug-in Installation Instructions
- Pega Robotic Automation Runtime 7.1 Installation Instructions
Summary of changes
This table summarizes the changes and updates included in the various Customer Requests (CRs) resolved in Pega Robotic Automation Studio/Runtime version 7.1. For more information on the features and enhancements in the initial release, see the Release Notes.
CR | Description | Assemblies |
---|---|---|
Build 7.1.98 — CR 51484 — February 07, 2018 | ||
BUG-318010 | This hotfix corrects several problems that could prevent the system from generating expected IE Focus events. | OpenSpan.Events.dll |
CR-51060 | This hotfix changes the system to prevent a deadlock when using the ParallelProcess component with an InteractionFramework event. | OpenSpan.Interactions.dll |
CR-52741 | This hotfix resolves a problem which arose if you installed Microsoft Windows Update KB 4056894. | OpenSpan.Scout.x32.dll |
Build 7.1.97 — CR 51374 — August 30, 2017 | ||
US-185987 | This hotfix adds support for Transport Layer Security (TLS 1.1 and TLS 1.2) cryptographic protocols, which you can use to provide communications security when making web connections. | OpenSpan.dll |
50013 | This hotfix adds additional logging and exception handling to help resolve Agile Desktop issues. | OpenSpan.Events.dll |
51201 | This hotfix corrects a problem which could occur when you launched multiple instances of the Fujitsu adapter. This problem prevented the File menu from appearing in every emulator window. | OpenSpan.Adapters.Text.Host.dll |
51197 | This hotfix resolves an issue which could cause shared memory exceptions when you had a large number of items in a combo box. | OpenSpan.Translators.Java.x32.dll |
51289 | This hotfix corrects a problem which could cause Internet Explorer to hang when downloading a file. | OpenSpan.Adapters.Web.dll |
Build 7.1.96 — CR 51063— August 04, 2017 | ||
51136 | This hotfix corrects a problem which could cause a diagnostics utility to return an incorrect value. This could then cause an exception in the injected application. | OpenSpan.Scout.x32.dll |
49552 | This hotfix corrects a SharedMemory leak which could occur when working with PowerBuilder. | OpenSpan.Adapters.DataGrid.dll |
US-153205 | This hotfix adds High Level Events (HLEs) to track the ProcessWaitStarted/ProcessWaitEnded and WebPageLoadStarted/WebPageLoadEnded events. This information is used by Pega Workforce Intelligence to do wait time analysis. | OpenSpan.Events.dll |
50013 | This hotfix corrects a problem which could cause Agile Desktop to crash when run from Studio and you were using Operational Events. | OpenSpan.Events.dll |
Build 7.1.94 — 7.1.95 | ||
| The changes in these builds were published in build 7.1.96. |
|
Build 7.1.93— CR 50942 — June 02, 2017 | ||
50332 | This hotfix adds support for RightClickRow on VSFlexGrid. | OpenSpan.Translators.VideoSoft.VSFlexGrid7.x32.dll |
50680 | This hotfix changes the system to avoid a problem which could occur when Internet Explorer was unresponsive while web controls were destroyed. This led to an exception that prevented the control from rematching correctly. | OpenSpan.Adapters.Web.dll |
50578 | This hotfix unmasks several fields so they can be used by Workforce Intelligence, including the following fields: AppName, UserName, MachineName, WebDomainName, MACAddress, ProcessId, and DomainName. | OpenSpan.Runtime.Analytics.dll |
50896 | This hotfix improves focus processing in Runtime and adds an accessibility handshake between Chrome, High Level Events (HLEs), and Runtime. | OpenSpan.Events.dll |
Build 7.1.92— CR 50632 — May 08, 2017 | ||
47824 | This hotfix corrects a problem which could cause Siebel OpenUI control types to break when you interrogate a text box. | OpenSpan.Adapters.Siebel.dll |
50578 | This hotfix lets you create a list of the fields in the event metadata to unmask for use in Workforce Intelligence. This includes the following fields: AppName, UserName, MachineName, WebDomainName, MACAddress, and DomainName. | OpenSpan.Runtime.Analytics.dll |
49392 | This hotfix adds support for the Infragistics .NET2 v11.2 UltraGrid control. If you have already interrogated the UltraGrid as a generic control, you will need to interrogate it again to get a Grid control. | OpenSpan.Adapters.dll |
43945 | This hotfix adds support for the Infragistics .NET2 v10.1 UltraTabControl. If you have already interrogated the UltraTabControl as a generic control, you will need to interrogate it again to get a Tab control. | OpenSpan.Adapters.dll |
50517 | This hotfix adds support for clicking a check box in a cell of a ListViewItem in a WPF ListView control. | OpenSpan.Adapters.Virtual.dll |
48397 | This hotfix corrects a problem which could prevent ContextMenuItems from being interrogated and which could also log a warning that the IEFrame Control should be interrogated. | OpenSpan.Adapters.Windows.Design.dll |
50149 | This hotfix changes the system to let the translator get the icon from JTabbedPane. | OpenSpan.Virtual.Interfaces.dll |
47796 | This hotfix corrects a problem which could cause Runtime to hang when you clicked the Runtime tray icon to display the Runtime menu. | OpenSpan.ApplicationFramework.dll |
Build 7.1.91— CR 50487 — March 24, 2017 | ||
49987 | This hotfix changes the way Cell Focus Events fire to make sure these events are properly handled when you update from Siebel 8.1.1.11 to 15.11. | JavaScript/*.js |
Build 7.1.90— CR 50351— March 02, 2017 | ||
EPIC-21257 | This change adds support for running multiple Universal Web Adapters to simultaneously automate the Google Chrome browser. Here are some additional benefits:
- Chrome can be running when you start a Chrome Universal Web Adapter. The adapter will catch up with the top level documents already running. - There are now multiple ways to close a document within a Chrome browser. For instance, you can stop the browser, stop just matched documents, stop all tracked documents, or do nothing. For more information, see the BrowserStopMethod property. - Tabs are now accurately tracked while interrogating and at runtime. Controls correctly highlight the selected tab’s controls as the interrogation cursor moves over each Chrome window. - Because all documents are visible to all Chrome Universal Web Adapters, use the new AcceptedDomains property to specify which domains the adapter should recognize. This lets you focus the adapter on only those documents you want it to process. Note these changes: - The List Browsers and Frames button is now the List Windows and Documents button. When you click this button, the system shows all tracked documents with the parent for each tracked document being the browser form the document resides in. This shows you that the relationship between a top-level document and its form is dynamic. You can tear off a tab into a new form or drag a tab from one form onto another and join it to that form. - To implement this feature, Studio/Runtime no longer injects native modules into the Chrome process. Instead, the Pega Robotic Automation Chrome extension is loaded in Chrome. This means these form-level functions, which require native injection, are no longer supported for Chrome: -- HideApplicationAtRuntime See Using multiple Chrome adapters within a Studio solution for more information. | OpenSpan.ChromeInstallerAdapter.dll |
BUG-291754 | This hot fix corrects a version numbering issue with the XSLT transformation which could occur when you updated to a Studio solution that was created between builds 7.1.49.0 and 7.1.88.0. | OpenSpan.dll |
Build 7.1.89— CR 50145 | ||
| The changes in this build were published in build 7.1.90. |
|
Build 7.1.88 — CR 49742 — February 13, 2017 | ||
49715 | This hotfix changes the system to omit excess logging information for Windows Presentation Foundation (WPF). | OpenSpan.Translators.DotNet.v20.Broker.dll |
49682 | This hotfix corrects a problem which could cause .NET applications to crash. | OpenSpan.Scout.x32.dll |
45752 | This hotfix changes the system so that it will remove whitespace to make sure it correctly matches process names. | SlimShortcuts.js |
48232 | This hotfix lets you configure how the system creates WindowsForms controls. If necessary, you can delay processing these controls so the UI loads as quickly as possible. Only use this capability under the direction of Robotic Automation Studio support. | OpenSpan.Translators.DotNet.v20.Broker.dll |
49973 | This hotfix corrects an issue which could prevent you from injecting into an application when running Windows Server 2003. | OpenSpan.Scout.x32.dll |
Build 7.1.87 — CR 49672— February 13, 2017 | ||
49688 | This hotfix removes some redundant code. | OpenSpan.Adapters.Windows.dll |
39259 | This hotfix changes the system to make sure it ignores Stop events from unsupported text adapters. | OpenSpan.Adapters.Text.Host.dll |
49385 | This hotfix corrects a problem which could cause a crash in SAP version 7.4. | OpenSpan.Translators.SAP.x32.dll |
48443 | This hotfix makes sure the system cleans out an internal collection in a DotNet translator. | OpenSpan.Translators.DotNet.v20.Broker.dll |
46998 | This hotfix adds an adapter to let you control an ICL emulator, such as the Fujitsu HostTalk emulator version 3.5 and higher. This new project item will appear as one of Studio’s Text adapters. You will need to set these properties: | OpenSpan.Adapters.Text.dll |
Build 7.1.86 — CR 49655 — December 08, 2016 | ||
US- | This hotfix changes the system to make sure event consumer requests are correctly handled by the Deployment Portal (formerly Management Console), regardless of whether you have the Analytics Consumer turned on in Workforce Intelligence. It also adds more logging information to help with debugging. | OpenSpan.dll |
48158 | This hotfix adds support for the SyncFusion TreeViewAdv control. | OpenSpan.Translators.Syncfusion.dll |
48145 | This hotfix adds support for the SyncFusion MDI Tab Panel control. | OpenSpan.Translators.Syncfusion.dll |
48253 | This hotfix adds the RichTextBoxPlus control which provides all of the functionality as Microsoft’s RichTextBox control but does not handle UserPreferenceChanged system events. To use this control, add it to the Visual Studio Toolbox, then drag it onto the Windows Forms designer. | OpenSpan.Controls.dll |
46358 | This hotfix resolves matching issues with FarPoint Spread 2.5. | OpenSpan.Adapters.Windows.dll |
48909 | This hotfix adds the GetRuntimeVersion method, which you can use to retrieve the Runtime version number. To use the GetRuntimeVersion method, add it to the Visual Studio toolbox, then drag it onto the Automation Designer surface. | OpenSpan.Runtime.Core.dll |
48445 | This hotfix adds support for clicking context menu items in WPF. To click a context menu item, show the context menu for the WPF control — for controls such as ListView you have to first select an item. Once the context menu appears, you can call the ClickContextMenuItem method. | OpenSpan.Adapters.DotNet.dll |
48365 | This hotfix resolves an issue that could prevent the GetItemContent method from working for WPF ListViews. | OpenSpan.Adapters.DotNet.dll |
46495 | This hotfix resolves an issue that could prevent a WPF control hosted inside a DotNet container from being correctly situated in the Object Explorer hierarchy. | OpenSpan.Translators.DotNet.v20.Broker.dll |
46293 | This hotfix adds support for Visual Basic 6 labels. | OpenSpan.Adapters.VisualBasic6.Design.dll |
45710 | This hotfix adds support for a custom Visual Basic control. | OpenSpan.Adapters.ActiveX.dll |
48389 | This hotfix changes the system to make sure SendKeys works for text fields when used through the IE Frame. | OpenSpan.Adapters.dll |
Build 7.1.84 — 7.1.85 | ||
| The changes in these builds were published in build 7.1.86. |
|
Build 7.1.83 — CR 49192 — December 08, 2016 | ||
48065 | This hotfix adds support for the Crescent Mask Text control. | OpenSpan.Adapters.FarpointOCX.Design.dll |
49159 | This hotfix changes the system so that a custom Java Grid translator now returns the total row count instead of the visible row count. | OpenSpanJavaAwtPVTableWrapper.class |
US- | This hotfix changes Runtime so that it sends additional information for the operational health reporting features in the Deployment Portal (formerly Management Console). This includes the user’s last login, last Runtime version, last package version and fatal exception information. | RuntimeConfig.xml |
Build 7.1.82 — CR 48958 — October 11, 2016 | ||
48825 | StartAndWait method could fail when starting and waiting for the same process. This would occur, for instance, when the Path property is set to the location of a .jar file and the TargetPath is set to javaw.exe. | OpenSpan.Adapters.Windows.dll |
45817 | This hot fix adds the GetSelectedRow method to the OpenSpanJavaCoffeeTableGridPanelWrapper class. | OpenSpanJavaCoffeeTableGridPanelWrapper.class |
48817 | This hot fix adds rules to handle exceptions and a UI flicker when using a reparenting container. | OpenSpan.Adapters.Windows.dll |
48149 | This hot fix adds the SyncFusion translator so you can interrogate a GroupBar control. | OpenSpan.Adapters.dll |
45179 | This hot fix adds the FileLocation key to the StartMyDay section in the RuntimeConfig.xml file. Use this key to set the location of the StartMyDay file. Here is an example. <StartMyDay> <AllowLocalApplications value= "true"/> <ShowPathColumn value="true"/> <FileLocation value=""/> </StartMyDay> When you enter an empty string as the value, the StartMyDay file is set to the config location specified in CommonConfig.xml file. This location is also used if this key is missing from the RuntimeConfig.xml file. This was the location used before this key was added. You can enter environmental variables, special folder names, and full paths. | OpenSpan.ApplicationFramework.dll |
48803 | This hot fix adds resolves an exception and disables ThinApp support — previously on by default — as it is not usually needed. Use the new Virtualization section in the openspan.ini file to enable or disable support for VMware’s ThinApp product. The default is zero (0) or disabled. Here is an example that shows the option enabled. [Virtualization] ThinAppSupport=1 Previously, support was enabled and you could not change it. | OpenSpan.Scout.x32.dll |
48332 | This hot fix changes Studio to make sure it waits until a script is needed before injecting it. | OpenSpan.Adapters.Web.dll |
48957 | This hot fix adds the AdvancedConfiguration property to the base Windows and Web adapters. This property has a Designer that lets you add key/value pairs as directed by Pega Support. Native translators have also been changed to now access the values in this new property. | OpenSpan.Adapters.Design.dll |
Build 7.1.81 — CR 48523 — September 29, 2016 | ||
48292 | This hotfix adds support for a custom Java grid that was embedded in a webpage. | OpenSpanJavaAwtPVTableWrapper.java |
48173 | This hotfix corrects issues with the innerHTML match rule which could prevent it from matching. | Openspan.Adapters.Web.dll |
48804 | This hotfix corrects a problem which could occur when you were using multiple text adapters. If Winhllapihost logging is enabled, the problem could cause Winhllapihost to crash. | OpenSpan.Adapters.WinHLLAPIHost.exe |
43404 | This hotfix addresses an issue which could prevent the content of a webpage from loading. | OpenSpan.Translators.InternetExplorer.x32.dll |
42380 | This hotfix changes Agile Desktop to make calls to automations asynchronous. This prevents Agile Desktop from having to wait until automations finish before performing the next function. | OpenSpan.AgileDesktop.CefSharp.dll |
48826 | This hotfix corrects a problem which could prevent Japanese character strings from being converted correctly. | OpenSpan.Translators.Java.x32.dll |
48227 | This hotfix modifies the system to lessen the chance of a Windows application crash when a null pointer exception occurs. | OpenSpan.ActiveX.x32.dll |
46805 | This hotfix adds limited support for the AWD (MFC 4.2) SECTreeCtrl tree control. | OpenSpan.Translators.AWD.x32.dll |
Build 7.1.80 — CR 48376 — September 06, 2016 | ||
45819 | This hotfix changes the system to make sure it relocates windows to their original position on a Move event. | OpenSpan.Consulting.WindowMgmt. |
44440 | This hotfix adds null checking to prevent a .NET exception thrown by OpenSpanSplitContainer when reparenting the PCOMM emulator. | OpenSpan.Consulting.WindowMgmt. |
46217 | This hotfix corrects the way the system counts login attempts and changes how it responds when the same credentials are re-entered to avoid an Assisted Sign-On “Failed Login Attempts” error. | OpenSpan.Adapters.dll |
43662 | This hotfix adds support for Oracle Forms menu items. | OpenSpan.Adapters.Design.dll |
46746 | This hotfix fixes a potential issue with resource data that could cause Internet Explorer to crash. | All native assemblies |
48524 | This hotfix adds high level event monitors for the Chrome and FireFox browsers. In FireFox, if a tab is un-docked and re-docked, events are no longer received for that tab. | OpenSpan.Events.dll |
45843 | This hotfix resolves a memory leak in the DOS Console Manager. | OpenSpan.Brokers.Windows.x32.dll |
32074 | This hotfix adds the ScrollIntoView method to web controls. | OpenSpan.Adapters.Web.dll |
44932 | This hotfix corrects a problem which could occur when you were using a web adapter with the StartMethod set to Start and another web adapter with a StartMethod set to MonitorAll. In this scenario, you would get the following message: Unable to start process iexplore.exe. Start process injected C:\Program Files (x86)\Internet Explorer\iexplore.exe failed | OpenSpan.Adapters.Windows.dll |
48474 | This hotfix makes sure WPF controls in a Windows forms application are correctly located in the adapter hierarchy. If you have already interrogated a control which was affected by this issue, you will need to interrogate the control again. | OpenSpan.Translators.DotNet.v20.Broker.dll |
39043 | This hotfix modifies the TextAdapter Screen WaitForInputAllowed method. Previously, the system would stop waiting if input was not allowed. Now it will wait until the screen is ready for input, up to the timeout interval you specified using this method. The behavior of existing automations which use the WaitForInputAllowed method will not be affected. For new automations only the updated WaitForInputAllowed method will be available for use. | OpenSpan.Adapters.Text.dll |
Build 7.1.79 — CR 48293 — August 26, 2016 | ||
48335 | This hotfix updates the system to handle new DotNet styles so you can use these styles on Windows forms. | OpenSpan.dll |
48291 | This hotfix removes the duplicate LogoUrl tag in the RuntimeConfig.xml so you can add a custom logo in Agile Desktop. | OpenSpanRuntimeEntSetup.aip |
44759 | This hotfix corrects a problem that could occur when an application throws an overflow error message when Studio is injected. | OpenSpan.Brokers.Windows.x32.dll |
48292 | This hotfix corrects a problem that could prevent custom Java wrappers from working with some static and non-static classes. | OpenSpanJavaReflection.class |
45025 | This hotfix adds support for the FarPoint Spread80 Grid. | OpenSpan.Adapters.FarpointOCX.Design.dll |
Build 7.1.77 — 7.1.78 | ||
| The changes in these builds were published in build 7.1.79. |
|
Build 7.1.76 — CR 48013 — August 05, 2016 | ||
48021 | This hotfix corrects a problem which could cause Agile Desktop’s Extended View to be blank. | OpenSpan.AgileDesktop.CefSharp.dll |
46295 | This hotfix changes the system to make sure keys are set before the data is passed. | OpenSpan.Automation.dll |
47935 | This hotfix resolves an issue which made the system think Google Chrome was running. | OpenSpan.Adapters.Windows.dll |
46614 | This hotfix changes the system to better handle certain Windows Presentation Foundation (WPF) applications which send a string of characters as an input text event instead of a single character. The system now parses all of the characters and sends a KeyPress event for each one. | OpenSpan.Translators.DotNet.v20.WPF.dll |
Build 7.1.75 — CR 47793 — July 21, 2016 | ||
46618 | This hotfix changes the system so that it no longer calls an activity complete before all the actions in the activity were finished. | OpenSpan.Automation.dll |
46993 | This hotfix makes sure the App bar can no longer be used as a drop point for files. | OpenSpan.AgileDesktop.CefSharp.dll |
Build 7.1.74 — CR 46476 — July 18, 2016 | ||
45597 | This hotfix removes a restriction which limited the Siebel.Text property to 1024 characters. | OpenSpan.Translators.InternetExplorer.x32.dll |
45666 | This hotfix corrects a problem which could prevent the system from matching the main Siebel view. | OpenSpan.SiebelOpenUI.Utility.js |
45038 | This hotfix adds the GetContextMenuItems method to window targets that can be accessed through an automation. Use this method to retrieve a list of the context menu items. | OpenSpan.Adapters.dll |
43018 | This hotfix corrects the versioning of Facet and FarpointGrid translator files. | OpenSpan.Translators.Facets.x32.dll |
46105 | This hotfix changes the system to make sure the AppLostFocus high-level event captures the target URL when Internet Explorer is shutting down. | OpenSpan.Events.dll |
45594 | This hotfix corrects a problem which could occur when you stored a large string in shared memory. The system now breaks the string into pieces to avoid the issue. | OpenSpan.Adapters.Java.dll |
46751 | This hotfix corrects a problem which could cause an exception when you close an interaction. | OpenSpan.Interactions.dll |
Build 7.1.73 | ||
| The changes in this build were published in build 7.1.74. |
|
Build 7.1.72 — CR 45984 — June 23, 2016 | ||
46051 | This hotfix corrects a problem which could prevent the Assisted Sign-On (ASO) manager from returning the correct value for the credentialsModified property. Furthermore, the credentials were not being saved to ASO.db when you used ShowCredentialDialog with no parameters. | OpenSpan.ApplicationFramework.dll |
41452 | This hotfix updates the version number on the Runtime splash screen. | OpenSpan.dll |
43018 | This hotfix corrects a problem which prevented you from retrieving the correct text from a ListBox in a Facet application. | OpenSpan.Translators.FarpointGrid.x32.dll |
41578 | This hotfix changes the system to make sure custom assemblies are referenced in all automations. | OpenSpan.Studio.dll |
45767 | This hotfix corrects a problem which could occur when using the Assisted Sign-On feature. The problem prevented the UserID and Password fields from appearing in the Credentials property when interrogated. | OpenSpan.Adapters.SAP.dll |
44885 | This hotfix changes the system so that it now converts all user IDs to lowercase when it retrieves them. This prevents case differences from creating duplicate users in Workforce Intelligence. | OpenSpan.dll |
41467 | This hotfix resolves an exception that could occur when using the CancelActivity method. | OpenSpan.Automation.dll |
45843 | This hotfix resolves a memory leak in the DOS Console Manager. | OpenSpan.Brokers.Windows.x32.dll |
32074 | This hotfix adds the ScrollintoMethod method to web controls. | OpenSpan.Adapters.Web.dll |
Build 7,1.71 — CR 45795 — June 09, 2016 | ||
45768 | This hotfix corrects a problem which could cause Internet Explorer version 11 to crash when you updated from build 7.1.68 to build 7.1.69. | penSpan.Translators.InternetExplorer.x32.dll |
45665 | This hotfix corrects a problem which could prevent Agile Desktop from loading if there was an octothorpe (#) in the path to the local files from the URI. | OpenSpan.AgileDesktop.CefSharp.dll |
Build 7.1.70 — CR 45408 — June 02, 2016 | ||
44734 | This hotfix corrects a problem which prevented the IdleStarted event from retaining SessionId or UserName data. | OpenSpan.dll |
43970 | This hotfix enhances Updater by letting you execute post update tasks, such as the Chrome and Firefox Extension installers. The new tasks for running the Chrome and Firefox Extension installers are defined in the PostUpdateTasks section of the RuntimeConfig.xml file. Be sure to set the enabled attribute to True to activate the task. You must have version 1.1.360 of Updater installed to use this feature. | Openspan.dll |
43666 | This hotfix corrects an error that could cause this message to appear when you ran Runtime: Could not get reference to OpenSpan.Automation. IExecutionTracker | OpenSpan.Adapters.dll |
41468 | This hotfix changes the system so that credentials are now saved before the dialog appears. The system now also checks to see if any values have changed. Based on this information, it sets the CredentialsModified value. | OpenSpan.ApplicationFramework.dll |
45050 | This hotfix corrects an issue that could cause an error when you included special characters, like a plus sign (+) or a space, in the name of a Studio project file. Studio was changing special characters into underscores when you deployed the project. | OpenSpan.Runtime.Core.dll |
44333 | This hotfix enhances the system to let you dynamically identify environmental variables. | OpenSpan.dll |
43086 | This hotfix corrects a problem which could prevent controls from matching because windows had not yet reparented. | OpenSpan.Adapters.Windows.dll |
43931 | This hotfix enhances the system so you can now use the WpfIdleTImeout property for Windows Presentation Foundation (WPF) controls in a web application. | OpenSpan.Adapters.Windows.dll |
41907 | This hotfix corrects a problem which could prevent an embedded active X control from being matched. | OpenSpan.Adapters.Web.dll |
41197 | This hotfix corrects a problem which could prevent an application with a VSFlexGrid8 from working after it displayed the grid. | OpenSpan.Adapters.Windows.dll |
Build 7.1.69 — CR 45294 — May 25, 2016 | ||
45210 | This hotfix corrects a problem which could prevent Siebel radio buttons from matching when the application is hidden or minimized. | OpenSpan.Translators.Siebel.SiebelCommon.x32.dll |
44182 | This hotfix corrects a problem which could prevent Siebel lists from expanding or collapsing when the application is hidden or minimized. | OpenSpan.Translators.Siebel.SiebelCommon.x32.dll |
44742 | This hotfix corrects a problem which prevented DOM mutation events (dynamically-generated HTML controls) from matching when these events were within a framed page. | OpenSpan.Translators.InternetExplorer.x32.dll |
44428 | This hotfix corrects a problem which could cause some Java applications to hang the UI while working. the system would then regard this as a hang and unwind the operation it was performing. If your project has a Java application that hangs the UI while performing a task, you can now use the new JavaInvokeTimeout property to define, at the adapter level, how long the system should wait for the Java application to complete its task before unwinding. You can increase the time-out interval or set it to zero (0) to make the system wait indefinitely. Keep in mind that setting the system to wait indefinitely increases the risk of a hang in the system if the application is actually hung and not just working for a long time on the UI thread. | OpenSpan.Adapters.Windows.dll |
| This hotfix corrects a problem with IeRematchEvents. | OpenSpan.Adapters.Web.dll |
Build 7.1.68 — CR 45035 — May 11, 2016 | ||
44149 | This hotfix corrects a problem which could prevent Agile Desktop toolbar images from displaying in multi-project solutions. | OpenSpan.AgileDesktop.exe |
43086 | This hotfix corrects a problem which could prevent controls from matching because windows had not yet reparented. | OpenSpan.Adapters.Windows.dll |
44380 | This hotfix includes these Agile Desktop Start My Day changes: - The StartMyDay adapter setting can change through an automation, however, the StartMyDay dialog always displays adapters that are set to Manual > Automatic at the start of the run. In other words, if an automation developer switches the setting to None , it will still appear on the dialog. - Lets you specify the order in which applications appear during an automation before the StartMyDay dialog opens. This overwrites the persisted user settings when showing the list, but this information is not set to the file so the end user can still change the order and those changes would persist. - Lets you add applications to the StartMyDay list via an automation. These items would be added to the StartMyDay file (if not already there) and would appear in the list as if the end user added them. Applications should be added as enabled . If an application is added with a friendlyName that is already in use for this package, it should not be added. Instead, the method should return False. This hotfix includes the following Assisted Sign-On changes: - Lets you add a comma-delimited list of categories into the Credential Collection Editor within the adapter. Include this list in the Optional section. This lets you create categories and assign credentials to those categories. The categories you enter into adapters that are present in the loaded solution will appear in the Credential dialog when the solution loads. - Lets you select multiple categories when viewing the Credential dialog. - Lets you display the Credential dialog via automation and have it automatically filter to the passed in category or list of categories. - Lets Runtime users easily see all categories at once. | OpenSpan.ApplicationFramework.dll |
Build 7.1.67 — CR 44529 — May 03, 2016 | ||
38880 | This hotfix adds a class that provides an off line fallback feature that is available when you are using shared drives and a web server. This is useful when you are using the AllowRunOffline option in the RuntimeConfig.xml file to determine how Runtime behaves when server connectivity fails. The XML file that tracks cached projects is located in DeploymentConfiguration.PackageDownloadPath. | OpenSpan.Runtime.Core.dll |
43640 | This hotfix enhances the support for the VSFlexGrid7 control from ComponentOne by adding support for the datagrid component. If you have existing OpenSpan.Translators.ComponentOne.VSFlexGrid8 translators in your solution, you may need to manually change your .os files to replace that translator with these new OpenSpan.Translators.VSFlexGrid.x32/x64 assemblies. | OpenSpan.Adapters.VideoSoftOCX.dll |
32089 | This hotfix adds the GetHandle method, which you can use to return the handle of a window. This method returns an IntPtr window handle of this target. It has no parameters. This method was added to all Windows controls. | OpenSpan.Adapters.Windows.dll |
33840 | This hotfix adds support for the OutlookBar control used in Northwoods’ Compass Pilot and modifies the PerformClick(buttonText) method to work with this control. | OpenSpan.Translators.DotNet.v40.OutlookBar.dll |
43145 | This hotfix modifies the system so that it now ignores blank sections in the Interaction.xml file. | OpenSpan.Interactions.dll |
28973 | This hotfix enhances the system so you can now add multiple attribute value match rules. This provides a more robust matching capability. | OpenSpan.Adapters.Web.dll |
43343 | This hotfix changes the system so that when you are running a Citrix solution and you encounter a null key, the system will pull the key information another place to make sure it is not null and no error is created. | OpenSpan.Automation.dll |
43348 | This hotfix corrects a problem which could cause an exception to be shown when the Runtime splash screen appeared. | OpenSpan.dll |
43186 | This hotfix changes the system so that Test Target Methods are shown as an option in the Match Rule Designer when you are interrogating. When you are not interrogating, Test Control Methods are now shown as an option in Object Explorer. | OpenSpan.Adapters.Design.dll |
36677 | This hotfix enhances the system to better track email address data in Outlook for analytical reporting purposes. | OpenSpan.Adapters.dll |
44502 | This hotfix corrects a problem that could cause Studio to crash when you interrogated a window which had been recreated in error. | OpenSpan.Adapters.Windows.dll |
42306 | This hotfix corrects a problem that could prevent the Navigate To options from working with variables in a global container. | OpenSpan.Automation.Design.dll |
43086 | This hotfix corrects a problem which could prevent controls from matching because windows had not yet reparented. | OpenSpan.Adapters.Windows.dll |
Build 7.1.66 — CR 44466 — April 14, 2016 | ||
44514 | This hotfix corrects an issue in Runtime where analytics events were not being sent to cloud storage. This build is a required update for all Workforce Intelligence customers who have updated past 7.1.59. | OpenSpan.Runtime.Analytics.dll |
Build 7.1.65 — CR 44412 — April 12, 2016 | ||
41923 | This hotfix corrects an issue causing Microsoft Internet Explorer version 11 to crash when a subscribed web browser event fired. | OpenSpan.Adapters.Web.dll |
43719 | This hotfix adds the IeRematchEvents property to the web adapter to address an issue where webpages did not automatically rematch after a menu was expanded. Ask Robotic Automation Studio support for assistance when modifying this property. | OpenSpan.Adapters.Web.dll |
44149 | This hotfix addresses an issue in Agile Desktop where images failed to display correctly when multiple projects were part of a Studio solution. | OpenSpan.AgileDesktop.exe |
44217 | This hotfix corrects an issue where control destroyed notifications were not being sent for Windows Presentation Foundation (WPF) controls. To address this issue, the system will now track the top-level container handle (hWnd) property of each WPF control, and use it to send the control destroyed notification. | OpenSpan.Translators.DotNet.v20.Broker.dll |
44294 | This hotfix changes how execution time, used in system reports, is recorded for an automation which connects to a sub-automation using a Jump To block. Prior to this change, the sub-automation's execution time was recorded twice — first for the sub-automation and a second time for the parent automation. | OpenSpan.Automation.dll |
Build 7.1.64 | ||
| The changes in this build were published in build 7.1.65. |
|
Build 7.1.63 — CR 44000 — March 29, 2016 | ||
30142 | This hotfix adds support for the 32- and 64-bit versions of Microsoft Office 2013 and Office 2016. It also adds support for 64-bit versions of Office 2010. You can select support for these versions of Office when you install this update via the Setup wizard or via the command line installation options. See the applicable installation instructions for more information. | OpenSpan.Office.Design.dll |
42619 | This hotfix adds the RuntimeMenuTray section to the RuntimeConfig.xml file. You can use the options in this section to configure the menu that appears when you click the Runtime icon in the system tray. For instance, Workforce Intelligence associates can use this option to open the Enter Expected Hours window. Here is a summary of the items you can place on the menu: - LoadLocalProject - Loads local projects. For more information on these options, see this Help topic: Runtime Configuration Settings XML File | RuntimeConfig.xml |
42617 | This hotfix includes these Agile Desktop changes: - Adds Clickable support to the 360 View plug-in items. This lets you click on an image or other context item to start an automation, activity, or go to a URL. For information, see the Using the Interaction.xml File topic in Help. | OpenSpan.AgileDesktop.CefSharp.dll |
38028 | This hotfix modifies Runtime so that it can now aggregate and send data to the Deployment Portal (formerly Management Console). This data will be used in the usage report which will be included in a future release of the Deployment Portal. | OpenSpan.IPC.dll |
42336 | This hotfix adds support for 64-bit Internet Explorer version 11. | OpenSpan.Translators.InternetExplorer.x32.dll |
39497 | This hotfix corrects a shared memory issue that could prevent the system from creating virtual controls. | OpenSpan.IPC.dll |
Build 7.1.61 — 7.1.62 | ||
| The changes in this build were published in build 7.1.63. |
|
Build 7.1.60 — CR 43560 — March 21, 2016 | ||
39630 | This hotfix corrects a problem which occurred when you used the text adapter and would trigger this error message: The function failed due to a system error. This message occurred because two WinHLLAPI function calls were being made simultaneously to the emulator. This hotfix also addressed an issue which could cause WinHllapiHost to crash during start up. The crash occurred while trying to invoke onto the form thread or while writing to the log during initialization. Make sure automations do not send commands to the emulator while the adapter is responding to a screen changed event. You can avoid this by not sending commands when the state of the screen is unknown. For example, only do this after waiting for or receiving an event that a screen was created. Or, use WaitForInputAllowed to make sure the screen is ready for input. | OpenSpan.Adapters. |
43552 | This hotfix corrects a problem that could prevent you from interrogating Oracle Forms. | OpenSpan.Translators.Java.x32.dll |
41864 | This hotfix adds support for a custom Java label. If you have already interrogated this control, re-interrogate the control to have it recognized as a label. | OpenSpan.Translators.Java.x32.dll |
43639 | This hotfix corrects a problem which could prevent the CSG translator from loading. | OpenSpan.Scout.x32.dll |
40828 | This hotfix corrects a problem which could occur when you tried to collect events from a WPF ComboBox. | OpenSpan.Adapters.dll |
43672 43252 42357 42800 43534 42356 42930 | This hotfix addresses these issues: Studio could not interact with icons in an OpenUI list that expanded rows. You can use the new CellExpandCollapseRow method to expand and collapse rows. In legacy Siebel, this method performs the same function as CellPerformClick. In OpenUI, there is a DIV element within this cell that is identified because it contains a specific classname. Clicking on this DIV causes the rows to toggle expanding and collapsing. - Studio did not recognize the first column of list if the cell had an Expansion Icon. Now Studio determines whether the first column is visible and change the index accordingly. - An exception was thrown when using GetSelectedRows on the OpenUI list. The way the system handles switching between events in the same view has been changed to avoid this error. The CellControlLostFocus event was not triggered in OpenUI when users tabbed out of a cell. Now the system looks for both mouse and keyboard events when the lost focus event fires. - The CellLinkClick event was not being captured. The CellLinkClick event now fires correctly and is captured. - Some OpenUI controls were not being recognized during interrogation, which could result in web controls instead of Siebel controls. The interrogation process has been changed to correct this problem. | OpenSpan.IOpenUISiebelApp.js |
Build 7.1.59 — CR 43341 — March 08, 2016 | ||
42828 | Microsoft security updates KB 3126593 and higher contain changes that prevent Studio from interrogating applications. This update modifies Studio to be compatible with these Microsoft changes. | OpenSpan.Scout.x32.dll |
Build 7.1.58 — CR 43184 — March 03, 2016 | ||
42828 | This hotfix removes changes introduced in build 7.1.56. | OpenSpan.Scout.x32.dll |
39116 | This change affects Workforce Intelligence. This hotfix adds the testUser key to the RuntimeConfig.xml file. This key tells the system if the user is a test user. The default is False. | OpenSpan.Runtime.Analytics.dll |
39780 | This change affects Workforce Intelligence. This hotfix lets you create rules for the running of applications. These rules are stored in the RuntimeConfig.xml file | OpenSpan.Runtime.Analytics.dll |
39625 | This change affects Workforce Intelligence. This hotfix lets you remove sensitive data using regex rules in the RuntimeConfig.xml file. Use the new fieldNames and eventNames keys to list the fields and events you want the system to inspect to determine if a rule should apply to a given event. | OpenSpan.Runtime.Analytics.dll |
39117 | This change affects Workforce Intelligence. This hotfix lets Runtime import screen rules and categorize screens into a collection of known screens. All screens for which a rule is not applied are grouped together and categorized as Unknown . For more information on these new keys, see Runtime Configuration Settings XML File. | OpenSpan.Runtime.Analytics.dll |
Build 7.1.57 — CR 43071 — February 24, 2016 | ||
43117 | This hotfix corrects a problem which, when debugging a project in Studio, could prevent Runtime from starting if Studio was connected to the Deployment Portal (formerly Management Console) via ADFS or STS. | OpenSpan.dll |
42828 | Microsoft security updates KB 3126593 and higher contain changes that prevent Studio from interrogating applications. This update modifies Studio to be compatible with these Microsoft changes. | OpenSpan.Scout.x32.dll |
Build 7.1.56 | ||
| The changes in this build were published in build 7.1.57. |
|
Build 7.1.55 — CR 42102 — February 08, 2016 | ||
41673 | This hotfix modifies the system to make sure sensitive data is not logged by global variables. | OpenSpan.Interactions.dll |
41200 | This hotfix corrects a problem which could cause match in process to fail. Now if match in process fails, the system lets the matching service handle matching out of process. | OpenSpan.Adapters.dll |
40696 | This hotfix adds the WPFIdleTimeout property to the dotNet translator so you can now search for and create WPF controls in a more controlled manner. This can prevent a target application from hanging when working with a screen that contains WPF controls which change frequently. The WPFIdleTimeout property only applies to adapters that are used with WPF applications. The default is zero (0), which means the WPFIdleTimer is not used and the previous behavior is maintained. If, for instance, you set the WPFIdleTimer property 300, the dotNet translator will wait for the WPF user interface to be idle for 300 milliseconds before it searches for and creates new WPF controls. If the WPF user interface does not become idle within two seconds, the system times out and then searches for and creates new WPF controls. | OpenSpan.Adapters.Web.dll |
Build 7.1.54 — CR 41668 — January 22, 2016 | ||
40612 | This hotfix corrects a problem which could prevent you from adding context menu items when interrogating a website. Keep in mind that if Studio cannot get the text of owner-drawn menu items it assigns [OWNER DRAWN] to the control that is created to represent them. The position of the menu items must remain consistent for Studio to correctly identify them. | OpenSpan.Adapters.Windows.dll |
40797 | This hotfix modifies the system to make sure high level events include the Deployment Portal (formerly Management Console) user ID value. | OpenSpan.dll |
40892 | This hotfix adds a Help option to the command line parameters for the ShutdownRuntime utility. Append ? or Help to see information about all available parameters. Here is an example: ShutdownRuntime.exe help | ShutdownRuntime.exe |
41617 | This hotfix corrects a problem which prevented server SSL certificates for web requests from being validated after the first analytics payload was sent. | OpenSpan.Runtime,Analytics.dll |
Build 7.1.53 — CR 41552 — January 07, 2016 | ||
41560 | This hotfix corrects a problem that could occur when using Updater to restore an earlier version of Runtime. For instance, this could cause a failure to authenticate and force a Runtime user into off line mode when downgrading from versions 7.1.51 or 7.1.52 to 7.1.49 or earlier. | OpenSpan.Server.Client.dll |
Build 7.1.49 — 7.1.52 | ||
| The changes in these builds were published in build 7.1.53. |
|
Build 7.1.49 — CR 40910 — December 16, 2015 | ||
40974 | This hotfix adds support for the Chrome browser using the Universal Web Adapter. This includes a new Chrome extension. Keep in mind these limitations: - You can interrogate cells within simple tables but the table designer is not available for the Universal Web Adapter. Complex tables cannot be matched based on the table schema. - Property changed events are not supported. - Cancellable events are not supported. - Plug-ins, such as Java and Flash, are not supported. - When uninstalling Runtime or Studio, the Firefox/Chrome extensions will be left in place, however these extensions cannot be used. - There is no utility for converting a legacy Web Adapter into a Universal Web Adapter. - The Universal Web Adapter does not support event collection for Workforce Intelligence. Chrome-specific limitations: - Multiple concurrent adapters are not allowed. If you try to start a second Chrome adapter, Runtime throws an exception. Even if you use a new profile, it will still fall under the top-level process, which is the process you injected into. - Frames are not supported. This implementation only works with the top-level document in web applications. - Non-global webpage interrogations are not supported. - When installing the Chrome extension and running for the first time on a Runtime machine, end users must respond to a prompt which asks if they would like to enable or uninstall the Chrome Extension. End users must enable the extension for Runtime to inject. If an end user does not enable the extension, a manual process must be run to recover and install the extension again. - Extensions allowed to run in the background can prevent the adapter from being able to start Chrome. If any chrome.exe process is running when the adapter is launched, you will not be able to inject (interrogate or automate). As with all releases, follow best practices when migrating to a new version of Studio/Runtime. Always back up existing solutions before opening the solution in the new version. | OpenSpan.ChromeExtensionInstaller.exe |
Build 7.1.48 — CR 40802 — December 14, 2015 | ||
40642 | This hotfix corrects a problem which could occur when interrogating a grid within PowerBuilder. | OpenSpan.Translators.PowerBuilder.x32.dll |
Build 7.1.47 — CR 40788 — December 10, 2015 | ||
33943 | This hotfix adds the DisplayConnectionError key to the CommonConfig.xml file. The default is True, which tells the system to display any connection errors. | CommonConfig.xml |
Build 7.1.46 — CR 39087 — December 10, 2015 | ||
39115 | This hotfix enhances performance by removing and replacing system calls that adversely affected performance in high process count environments. | OpenSpan.Events.dll |
34699 | This hotfix adds options to the ShutdownRuntime utility which can help speed the shutting down of Runtime implementations. These options include: -noKill — Include this option if you want the tool to simulate the shutdown process but not actually shut down Runtime. This option is for testing purposes only. -useWMI — Include this option to get the process user name via Windows Management Instrumentation instead of via native calls. -useThreadPool — Include this option to shut down thread pool threads instead of the current thread. -CompareSessionIDs — Include this option to use the session ID instead of the process user name when shutting down a specific Runtime instance. | ShutdownRuntime.exe |
33943 | This hotfix changes the default for the DisplayConnectionError key in the CommonConfig.xml file from True to False. | CommonConfig.xml |
Build 7.1.45 — CR 39725 — November 23, 2015 | ||
39043 | This hotfix addresses concurrency and simultaneous matching issues which could produce exceptions when automating a HllApi emulator. | OpenSpan.Adapters.Text.Host.dll |
Build 7.1.44 — CR 39276 — November 18, 2015 | ||
39591 | This hotfix updates the translators to handle changes implemented in a new version of CSG. | OpenSpan.Translators.CSG.x32.dll |
Build 7.1.43 — CR 39039 — November 13, 2015 | ||
38823 | This hotfix changes the way Siebel SetCellValue handles values. Previously, values were truncated to 95 characters. Now there is no limit to the length of the value. | OpenSpan.Adapters.Siebel.dll |
39228 | This hotfix corrects a problem which caused an error when you navigated to applications displayed in compatibility mode in Internet Explorer version 11. | OpenSpan.js |
37292 | This hotfix resolves issues with the grid and toolbar interrogation of SAP applications. | OpenSpan.Scout.x32.dll |
Build 7.1.42 — CR 38546 — November 06, 2015 | ||
| This hotfix changes a default in the installation wizard. Enabling Intelligence now is unchecked by default. | Installation files |
37548 | This hotfix adds the NoteCharacterLimit attribute in the Notes plug-in Config sections which you can use to specify the maximum number of characters which a user can enter in the Notes plug-in. Here is an example: <Config> <LineBreak>\r\n</LineBreak> <NoteCharacterLimit>140</NoteCharacterLimit> </Config> This example sets the maximum number of characters to 140 and tells the system to count the Enter key as the number of characters specified in the LineBreak attribute. For example, by setting LineBreak to \r\n, an Enter key will count as two characters — \r and \n count as one character each. | AgileDesktop/OpenSpan.AgileDesktop. |
37937 | This hotfix adds the InnerLabel attribute to the Information section. You can use this attribute to change the default label, Contact Information , to something else. Also, value labels now wrap in the Information section. | AgileDesktop/OpenSpan.AgileDesktop. |
37938 | This hotfix increases the width of label in the Eligibility section in Agile Desktop. | AgileDesktop/OpenSpan.AgileDesktop. |
37940 | This hotfix adds tooltip support to show the full text of a context value if the value is truncated. | AgileDesktop/OpenSpan.AgileDesktop. |
38112 | This hotfix decreases the line spacing when context values are displayed on multiple lines in the 360AppBar. | AgileDesktop/OpenSpan.AgileDesktop. |
30050 | This hotfix changes the system to make sure the RuntimeLoader.AllProjectStarted event fires even if Runtime/Agile Desktop is not connected to the Deployment Portal (formerly Management Console). | OpenSpan.Runtime.Core.dll |
36480 | This hotfix adds support for the FarPoint Spread 2.5 COM control. | OpenSpan.Adapters.FarpointOCX.Design.dll |
Build 7.1.41 — CR 38088 — October 27, 2015 | ||
29358 | This hotfix adds support for interrogating and automating Firefox. An extension to Firefox is used to add this functionality via the new Universal Web Adapter. This version will work for Firefox versions from 31 to 39 and for Firefox ESR versions from 31.6.0 to 38.3.0 (expected to work until Firefox ESR 38.8.0 that is due for end of life in May 31, 2016). The Setup wizard now gives you the option of installing the FireFox plug-in. You can also use the new INST_FIREFOX=1 command line option to install the Firefox plug-in from the command line. If omitted, the Firefox plug-in is not installed. Keep in mind these limitations: - You can interrogate cells within simple tables but the table designer is not available for Firefox. Complex tables cannot be matched based on the table schema. - Property changed events are not supported. - Cancellable events are not supported. - Plug-ins, such as like Java and Flash, are not supported. - Multi-tab functionality for Firefox is not supported during interrogation. Multi-tab functionality will work with automations, however, tabs cannot be pulled apart from the original window when Studio is injected. - Multiple top-level windows are not supported when Studio is injected. - Multiple concurrent Firefox processes cannot be automated under the same user profile. The Universal Web Adapter will always open under the default user profile. If you need to have multiple concurrent Firefox processes, use the Windows adapter instead and specify the user profile within the Arguments property. - If Studio loads Firefox in a user profile that is actively running, the current process will request to shut down. Because of this, it is a best practice to start Firefox adapters at the project start and to not close them throughout the automation. - The Universal Web Adapter does not support event collection for Workforce Intelligence. As with all releases, follow best practices when migrating to a new version of Studio/Runtime. Always back up existing solutions before opening the solution in the new version. | These assemblies were added: OpenSpan.Adapters.Web.Universal.dll |
Build 7.1.39 — 7.1.40 | ||
| The changes in these builds were published in build 7.1.41. |
|
Build 7.1.38 — CR 37807 — October 13, 2015 | ||
37525 | This hotfix removes a logging dialog which could prevent Runtime/Agile Desktop from connecting to the Deployment Portal (formerly Management Console). | OpenSpan.dll |
37790 | This hotfix corrects a problem that affected PowerBuilder’s DataGrid CheckBoxColumn. | OpenSpan.Adapters.DataGrid.dll |
| This hotfix improves logging in the Java Translator. | OpenSpan.Translators.Java.x32.dll |
27671 | This hotfix corrects a problem which could prevent a Click event from being raised when an UltraTreeNode was clicked by a Studio automation. | OpenSpan.Translators.DotNet.v40. |
37326 | This hotfix makes sure WPF ComboBox SelectedItems return the item text instead of an object description. | OpenSpan.Translators.DotNet.v20.WPF.dll |
37327 | This hotfix makes sure WPF ListBox SelectedItems return the item text instead of an object description. | OpenSpan.Translators.DotNet.v20.WPF.dll |
33281 | This hotfix makes sure UserModified events fire for WPF controls. | OpenSpan.Adapters.DotNet.dll |
33455 | This hotfix makes sure the ParentObjectId is available when the Created event for WPF controls fires. The Created event now fires after the parent has been set, to make sure the ParentObjectId is available. | OpenSpan.Adapters.Virtual.dll |
Build 7.1.37 — CR 37223 — October 02, 2015 | ||
34984 | This hotfix corrects a problem which could occur when you moved execution links from one automation block to another instead of deleting and recreating the execution links. This could cause the loss of key information. | OpenSpan.Automation.Design.dll |
36164 | This hotfix adds an entry in the CommonConfig.xml file to facilitate communication between the Runtime/Agile Desktop and Workforce Intelligence servers. The entry should look similar to this example: <Server name="Intelligence" baseURL="https://wfi.openspan.com/" enabled="true" proxyAddress=""/> The Off Computer Time and Expected Work Hours dialog rely on this setting. | OpenSpan.dll |
Build 7.1.36 | ||
| The changes in this build were published in build 7.1.37. |
|
Build 7.1.35 — CR 36606 — September 18, 2015 | ||
36775 | This hotfix adds the Agile Desktop settings for ViewType and CustomImagePath into the RuntimeConfig.xml file. - ViewType - Use this key to define the initial toolbars view. You can choose from normal, slim, normal_only, and slim_only. If you choose normal or slim, the user can resize the toolbar after it initially appear. - CustomImagePath - Use this key to specify the path to custom images used in the 360AppBar plug-in’s Images section. Here is an example: <ViewType value=”normal_only”/> Normally, when you want to include a custom image in the 360AppBar Image section, you would add the image to the startup automation project as misc files and specify the image name in Interaction.xml file. Alternatively, you can put all of the custom image files in a folder and specify that folder’s path as the value to CustomImagePath key. | None |
| This hotfix corrects a problem which could cause SuperTrace to log the same information twice. | OpenSpanJavaTracing.class |
35819 | This hotfix corrects a problem which could cause hangs when using Java. Since there was a change to Java class files, you must rebuild and redeploy your solution to make sure your deployment contains the latest java classes. | OpenSpan.Adapters.Windows.dll |
35819 | This hotfix enhances the system so you can enable SuperTrace for a list of users. Use the AutUsers key in the SuperTrace section to enable SuperTrace for a particular user or users. Simply add a comma-delimited list of user logon names in this key. | OpenSpan.SuperTrace.x32.dll |
33918 | This hotfix corrects a problem that could cause Internet Explorer to crash after applying updates. | OpenSpan.Translators.InternetExplorer.x32.dll |
Build 7.1.34 — CR 35514 — September 02, 2015 | ||
34326 | This hotfix adds the DropdownMenu type for the ShortcutType attribute in the Interaction.xml file. You can use this new option in Agile Desktop to display a pop-up menu when it is clicked. | Shortcuts.coffee |
34904 | This hotfix makes the <section> tag names in the interaction.xml file case insensitive. | Interaction.coffee |
33380 | This hotfix corrects a problem that prevented the StartInteraction plug-in from correctly passing input strings to its corresponding automation project entry point and from correctly receiving output from the automation’s exit point. | OpenSpan.Automation.dll |
34550 | This hotfix adds support for the Visible attribute on the 360AppBar items. You can enter a criteria expression for the value of Visible. This lets you indicate which items in the 360AppBar are visible, based on Context and Global values. | 360AppBar.coffee |
34069 | This hotfix adds support for buttons with two rows of label text. | Shortcuts.coffee |
Build 7.1.33 — CR 34949 — August 11, 2015 | ||
34045 | This hotfix corrects a problem which could prevent the Start My Day feature from launching non adapter web applications. | OpenSpan.Application.Framework.dll |
33623 | This hotfix changes how table elements are added to a control to enhance performance. Previously, Studio sometimes appeared to be hung when you used HTML Table Designer with very large HTML tables. | OpenSpan.Adapters.Web.Design.dll |
34699 | This hotfix enhances performance in situations where you have a high user load in Citrix environments. | OpenSpan.dll |
32126 | This hotfix refactors how the system retrieves items from virtual List controls to require less shared memory. This can prevent application crashes when working with a virtual List control that contains an extremely large number of items. | OpenSpan.Adapters.DotNet.dll |
34722 | This hotfix corrects a problem which could cause excessive memory use in the JVM when processing the UserModified event for a custom Swing table. | OpenSpanJavaSwingTableWrapper.class |
32543 | This hotfix adds support for the SysTreeView32 control. | OpenSpan.Adapters.CSG.Design.dll |
35345 | This hotfix corrects a problem which could occur if you tried to change global values from a different global values changed event. | OpenSpan.Interactions.dll |
Build 7.1.32 — CR 34317 — July 23, 2015 | ||
34266 | This hotfix corrects a problem which could prevent an activity from starting. | OpenSpan.Interactions.dll |
32542 | This hotfix adds support for the CSG LIstbox control. | OpenSpan.Adapters.CSG.dll |
32544 | This hotfix adds support for the CSG Grid control. | OpenSpan.Adapters.CSG.dll |
26213 | This hotfix corrects a problem which could prevent the system from getting the executable path for some processes during Events logging. | OpenSpan.Events.dll |
Build 7.1.31 — CR 34024 — July 15, 2015 | ||
33384 | This hotfix corrects a problem with hooking which could occur when you navigated to a specific page in SAP version 7.4. | OpenSpan.Translators.SAP.x32.dll |
33450 | This hotfix changes the system to now recognize xButtons as options in Studio’s mouse event handlers. | OpenSpan.Virtual.Interfaces.dll |
28666 | This hotfix adds limited support for the JWLISTLIST and JWLISTBOX controls. | OpenSpan.Adapters.JWalk.dll |
Build 7.1.30 — CR 3972 — July 09, 2015 | ||
33292 | This hotfix changes the default for the ShowDialogOnStart option in the RuntimeConfig.XML file from True to False. This affects Assisted Sign-on. | This is an installer/RuntimeConfig change. No assemblies or Agile Desktop files were affected. |
33024 | This hotfix changes the system to make sure Agile Desktop plug-ins that are designated as hide-able no longer appear on the Gear menu. There is a setting in the Interaction.XML file that determines if a plug-in is hide-able. | This change requires a new release of the |
33025 | This hotfix adds a Closing event to the InteractionManager component. You can cancel this event in an automation to keep the Interaction open, if necessary. | OpenSpan.Interactions |
33031 | This hotfix adds the solution and version number to the Agile Desktop About box. | OpenSpan.AgileDesktop.CefSharp |
33041 | This hotfix changes the isActive setting for the Notes plug-in. Now if you set isActive to True, the note will appear and if you set it to False, the note will be hidden. Previously, these settings were reversed. This change could affect your solutions. | This change requires a new release of the |
33046 | This hotfix changes the AddNote method passed in the InteractionKey from type Object to type String. This change could affect your solutions. | OpenSpan.Interactions |
33154 | This hotfix changes the behavior of the mouse cursor when an automation responds to the RuntimeLoader.Exiting event with a Do you want to close? message box. The mouse cursor no longer gets stuck in a spinner cursor when over the desktop or message box. | OpenSpan.AgileDesktop.exe |
33157 | This hotfix makes sure un-synced notes are deleted when you close the interaction. | This change requires a new release of the |
33175 | This hotfix makes sure MessageManifest.ShowMessage always moves to the top level. | OpenSpan.Controls |
32322 | This hotfix adds the Globals section to the Interaction.XML file. Items you add in this section can be referenced in automations using the GlobalDictionary component. This lets you share values across non-referenced projects. You add global items just as you would context items. | OpenSpan.Interactions |
32323 | This hotfix lets you display Global Dictionary values in the 360 View plug-in. | OpenSpan.AgileDesktop.CefSharp |
32325 | This hotfix provides ways to emphasize important data displayed on the Agile Desktop toolbar. | OpenSpan.AgileDesktop.Cefsharp |
30778 | This hotfix adds the DeleteASOFile method to the AssistedSignOn component which can be called from an automation. This lets you remove the Assisted Sign-On ASO.db file even when no passwords are stored in the file. | OpenSpan.ApplicationFramework.dll |
33185 | This hotfix changes the Notes plug-in so the user is prompted to sync any un-synced notes when he or she closes an interaction. | This change requires a new release of the |
33298 | This hotfix adds the following events to the default toolbar: - RuntimeLoader.AllProjectsStarted — Indicates that all projects are started and ready to go. - RuntimeLoader.Exiting — Indicates that Runtime/Agile Desktop is closing. These events are not added to existing installations but will be included in the default toolbar. | This change requires a new release of the |
33328 | This hotfix expands the contact information available to the plug-ins to include up to three email addresses and three phone numbers. | This change requires a new release of the |
28147 | This hotfix standardizes the use of case and verbiage throughout the Interaction.XML file to make it easier to understand and use. Items that do not meet this standard will still be supported. | Interaction.XML |
33295 | This hotfix corrects a problem which prevented shortcut buttons from working if you minimized the toolbar before opening an interaction and then maximized the toolbar. | This change requires a new release of the |
33036 | This hotfix changes Agile Desktop to enable shortcut buttons when there is no active interaction, as long as those activities are set to run without an interaction. | OpenSpan.AgileDesktop.CefSharp |
32345 | This hotfix enhances the Agile Desktop toolbar by providing ways for you to alert users of error conditions or other changing values. This hotfix adds dynamic styling and conditional formatting so you can call attention to displayed data that is outside of range or is not an expected value. | OpenSpan.AgileDesktop.Cefsharp |
32273 | This hotfix resolves an issue which could prevent projects that had spaces in their names from detecting idle time correctly. | OpenSpan.Events.dll |
2008 | This hotfix adds a translator for the Farpoint WinSpread Grid control. | OpenSpan.Translators.DotNet.v20.Farpoint.dll |
33121 | This hotfix insures that Studio can match all clones, regardless of how many clones it encounters. | OpenSpan.dll |
Build 7.1.29 — CR 33859 — July 01, 2015 | ||
32222 | This hotfix corrects an issue which prevented Internet Explorer from being properly injected in Virtual Desktop Infrastructure (VDI) environments. | Too numerous to list. |
Build 7.1.28 — CR 33858 — July 01, 2015 | ||
33799 | This hotfix ports a Windows Management control from Studio/Runtime version 5.x to version 7.1. | OpenSpan.Adapters.Windows.dll |
Build 7.1.27 — CR 33018 — June 29, 2015 | ||
32042 | This hotfix corrects an issue which could cause an exception when a user logged out of an application. | OpenSpan.Adapters.Web.dll |
29861 | This hotfix corrects a problem which could prevent Runtime from starting because of an authentication failure. | OpenSpan.dll |
29814 | This hotfix resolved a WinHllapiHost issue which could cause Runtime to become unstable. In addition, this hotfix adds logging to capture details when WinHllapiHost crashes and modifies logging in WinHllapiHost so it can be enabled through the RuntimeConfig.xml file. This key has been added to the RuntimeConfig.xml file: <add key="WinHllapiHostLoggingEnabled" value="false"/> | OpenSpan.Adapters.Text.dll |
32045 | This hotfix corrects a problem which prevented the system from matching correctly. This problem occurred when a web element changed while they system was already matching. Now, If there are webpage changes while the system is matching, it will match again once the page becomes idle. | OpenSpan.Adapters.Web.dll |
32565 | A bug in the Java Runtime Environment (JRE) between versions 1.7_u25 and 1.7_u65/1.8_u11 causes SwingUtilities.invokeLater to fail with a NullPointerException. If you encounter this JRE bug, a new AppContext in the System thread group is created so subsequent calls to SwingUtilities.invokeLater will succeed. Since this is a JRE issue, the preferred resolution is to update your JRE to a version which does not have this issue. For more information, see JRE Bug JDK-8019272 . | OpenSpan.Translators.Java.x32.dll |
Build 7.1.26 — CR 32347 — June 29, 2015 | ||
31329 | This hotfix corrects a problem which could prevent automatic matching from occurring on dynamically generated pages. | OpenSpan.Translators.InternetExplorer.x32.dll |
32348 | This hotfix adds these new rules to make it easier to match in-process with the web adapter: - WebControlChildrenMatchRule | OpenSpan.Adapters.dll |
32306 | This hotfix corrects a type resolution issue with the GetItemContent method so all WPF properties, methods, and events are available. | OpenSpan.Adapters.DotNet.dll |
32284 | This hotfix adds support for the Label match rule with .NET WindowsForms and WPF targets. | OpenSpan.Translators.DotNet.Virtual.dll |
32478 | This hotfix corrects a problem which could cause a fatal exception when you used high level events because an unexpected window was created in the EventHost process. | OpenSpan.EventHost.exe |
Build 7.1.25 — CR 32211 — May 25, 2015 | ||
30133 | This hotfix adds support for ComponentOne VSFlexGrid controls. | OpenSpan.Adapters.ComponentOneOCX.dll |
31587 | This hotfix adds the following keys to the StudioConfig.xml file so you can configure time-out interval values for HTTP web requests. This helps you avoid situations where package uploads fail in the Deployment Portal (formerly Management Console or OMC) because the client timed out. Use these keys to modify package upload HttpWebRequests: - UploadTimeout - Use this key to specify the maximum amount of time, in milliseconds, the request has to complete. The default is 100000, or 10 minutes. - UploadReadWriteTimeout - Use this key to specify the maximum amount of time, in milliseconds, the client has to read or write responses to the server. The default is 300000, or 30 minutes. - UploadKeepAlive - Use this key to specify whether the client should keep open the connection to the server. The default is False. Use these keys to modify HttpWebRequests: - WebRequestTimeout - Use this key to specify the maximum amount of time, in milliseconds, the request has to complete. The default is 100000, or 10 minutes. - WebRequestReadWriteTimeout - Use this key to specify the maximum amount of time, in milliseconds, the client has to read or write responses to the server. The default is 300000, or 30 minutes. - WebReqestKeepAlive - Use this key to specify whether the client should keep open the connection to the server. The default is False. | OpenSpan.dll |
31193 | This hotfix adds support for SAP version 7.4. | OpenSpan.Translators.SAP.x32.dll |
31483 | This hotfix updates the WPF translator to make sure it correctly responds to combo box selection changes. | OpenSpan.Translators.DotNet.v20.WPF.dll |
Build 7.1.24 — CR 31989 — May 14, 2015 | ||
31377 | This hotfix provides an easy way to start a single Start My Day application by adding these methods: - StartApplication(string applicationName) - Use this method to start a single application. - StartApplications(params string[] applicationName) - Lets you add more than one application to connection block inputs so you can start multiple applications. - StartApplicationList(string applicationName) - Lets you start all of the applications you include in the list. - ShowStartDialog() - Shows a list of applications that have not been started. You can select one application from list to start. | OpenSpan.AutomationFramework.dll |
28148 | This hotfix provides a way to prevent or ask for confirmation when user exits Agile Desktop via the gear icon. This hotfix adds a static Exiting cancellable event to the RuntimeLoader. You can use this event in an automation to present a confirmation dialog and, optionally, prevent Agile Desktop or Runtime from shutting down. | OpenSpan.AgileDesktop.exe |
31087 | This hotfix provides a way to determine the last time a user changed the password for an application by adding these methods to AsoManager: - Nullable<DateTime> GetDatePasswordChanged(string applicationKey, out bool passwordSet) - Returns the last date the password changed for an application. passwordSet is false if the user has never entered a password for the application. - in GetDaysSincePasswordChanged(string applicationKey) - Gets the number of days since the last password change for a given application. - bool IsPasswordSet(string applicationKey) - Indicates if the user has ever set the password for a given application. | OpenSpan.ApplicationFramework.dll |
31370 | This hotfix adds the VisibleRows key to the Shortcuts plug-in section of the Interaction.xml file. Use this setting to specify the number of shortcut rows you want to appear. | OpenSpan.Interactions.Controls.dll |
29556 | This hotfix adds support for additional UltraGrid (ActiveX control) properties, methods, and events. | OpenSpan.Adapters.InfragisticsOCX.dll |
Build 7.1.23 — CR 30985 — May 07, 2015 | ||
26315 | This hotfix adds support for the AWD List Control. | OpenSpan.Adapters.dll |
31031 | This hotfix resolves a handle leak which could occur when running OpenSpan Services. After installing this build, restart your computer. | OpenSpan.x32.sys |
26841 | This hotfix corrects a problem which could cause an exception when a CellLinkPerformClick was used. | OpenSpan.Adapters.Siebel.dll |
30957 | This hotfix adds MessageDetails to list of parameter types you can select from the Type drop down. | OpenSpan.Automation.Design.dll |
24262 | This hotfix makes sure the OSDump utility reads the RuntimeConfig.xml file from the EnviromentProperties.UserPath location. | OSDump.exe |
28423 | This hotfix adds the IgnoreProcesses key to the RuntimeConfig.xml and StudioConfig.xml files. Use this key to list the processes you want Studio and Runtime/Agile Desktop to ignore. Separate each process with a comma. The list of process names is case insensitive. | OpenSpan.Adapters.Windows.dll |
Build 7.1.22 — CR 30761 — April 17, 2015 | ||
30006 | This hotfix resolves a hooking issue in Internet Explorer which could cause Internet Explorer version 11 to crash on certain pages after you installed Microsoft KB 3003057 or one of its successive KBs. These KBs are known to exhibit this issue: | OpenSpan.Translators.InternetExplorer.x32.dll |
29706 | This hotfix updates the system to handle the use of a single interaction context variable. Multiple interaction contexts were already handled. | OpenSpan.Interactions.dll |
29991 | This hotfix resolves a conflict between Studio/Runtime and a third party product which could cause Internet Explorer version 11 to crash. | OpenSpan.Scout.x32.dll |
Build 7.1.21 — April 02, 2015 | ||
| This was the initial build of version 7.1. |
|
Previous topic Build notes: Pega Robotic Automation 8.0 Next topic Robotic Automation supported technologies