Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please update your bookmarks. This site will be discontinued in Dec 2024.

Pega Platform Resolved Issues for 8.1 and newer are now available on the Support Center.

SR-C82619 · Issue 421023

JavaILCompiler updated to skip a type convert when generating code for a ternary operation

Resolved in Pega Version 8.3

A compilation error was generated when attempting to save a Data Transform with a java expression giving the ternary as boolean. In this case, the pyWorkPage.Channel was set to  @java("tools.findPage(\"TempInputAccelPage\").getProperty(\"Channel\").getMessageCount()>0") ? "" : pyWorkPage.Channel.


The system previously used EL code generation, which had a gap which allowed such expression to work. Since the system now uses IL code generation, this expression failed. In order to ensure backwards compatibility, logic has been added to  JavaILCompiler to skip a type convert when generating code for a ternary operation where the source is ILProgramText (java expression).

SR-C79523 · Issue 421039

Updated the documentation for enabling debug logging during upgrades

Resolved in Pega Version 8.3

The documentation regarding enabling debug logging during upgrades has been updated to reflect the following information: To enable debug logging during installs, upgrades or prpcUtils invocations: The template logging configuration for installs, upgrades and prpcUtils is located within the scripts/config directory of the Pega Platform distribution. To change what gets logged, modify the prlog4j2.xml file (refer to https://logging.apache.org/log4j/2.x/manual/configuration.html#XML). Some of the utilities involved in the install and upgrade processes use java logging. To impact what is logged by these tools, modify the deploylogging.properties file in the same directory.

SR-D8794 · Issue 483814

Import ordering shifted to prioritize Functions and Libraries

Resolved in Pega Version 8.3

A runtime error was seen when running DataTransform getbranchandcbsadetails. Investigation showed that when getbranchandcbsadetails was imported, the RUF it referenced was not imported beforehand. To resolve this, the import ordering has been reworked to prioritize Function and Libraries by shifting Rule-Utility-Library and Rule-Utility-Function to be after Rule-Obj-Property* in the import order.

INC-142589 · Issue 595489

Corrected tooltip evaluation for multiselect

Resolved in Pega Version 8.4.3

After adding help text for a multiselect help icon with overlay on hover field, the value was not being sourced. Changing to a different type of help text or control type worked as expected. This was due to an error in case sensitivity, using pyToolTip when it should have been pyTooltip, and has been corrected.

INC-142714 · Issue 596554

Recent Cases from different applications available to open

Resolved in Pega Version 8.4.3

An enhancement has been added which will allow opening other application assignments in the Recent Cases section of the current application when the user has access to multiple applications.

INC-143005 · Issue 596954

Fluid Overlay displays as expected in Firefox

Resolved in Pega Version 8.4.3

After upgrade, using the Overlay format "Fluid" to perform the screening matches task in CLM using Firefox had an overlay that covered the entire screen but was missing the scrollbar to manage the content. This has been resolved by adding changes to support dynamic content (with scrollbar) for center overlay.

INC-128960 · Issue 571360

Corrected approval step task message

Resolved in Pega Version 8.1.9

When a case progressed to the approval step, the task name did not properly appear as part of the "Please approve or reject this" message. In another scenario, a portal which supported locale switching was not translating "Please approve or reject this" when the locale was switched, but instead displayed the message in the original language. Investigation traced this to the pzInstructionsForApproval data transform storing the localized field value, causing it to persist inappropriately. This has been resolved.

INC-131151 · Issue 572832

Resolved empty body for Reject email

Resolved in Pega Version 8.1.9

When using the pzEmailActions Section in Correspondence for Approve/ Reject functionality via email, there was no reply body in the email for Reject Option. This was due to the flow action for the Reject email being different than that of the Approve email, and has been resolved.

INC-131385 · Issue 573454

Swagger APIs updated

Resolved in Pega Version 8.1.9

The Swagger File APIs have been updated to ensure swagger document files generated meet specifications for editor.swagger.io .

INC-134370 · Issue 577635

Expanded Grid locking updated

Resolved in Pega Version 8.1.9

When using pyDashboadMyWorkList to show the cases of an operator with Master Detail in Read Only mode, the system was acquiring a lock on the expanded work object. To resolve this, the following changes have been made: * In activity Assign-pyAcquireObject, If the parameter bRODetails is true, do not call acquireWorkObject and do obj-open-by-Handle to get assignment and work page in pyAcquireObject activity. * In activity acquireWorkObject, the parameter skipWorkLock has been removed as acquireWorkObject should always acquire the lock.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us