INC-120326 · Issue 564437
Landing page refresh modified to avoid frequent reloads
Resolved in Pega Version 8.1.9
Approximately every two weeks, clients were able to login but it was not possible to work as the landing page refreshed constantly until all of the nodes were rebooted and the issue was cleared. Investigation indicated the frequent reloads were related to the cacheing of the operator details, and this has been resolved by updating the datapage reload strategy based on 'when' so frequent reloads will be avoided.
INC-130158 · Issue 572051
iOS file attachment works in Safari
Resolved in Pega Version 8.1.9
Attaching PDF and images from iOS devices using Safari was not working. This was traced to iOS 13 launching the file browser by default if the file-input element had an accept=/ attribute value pair, and has been resolved.
INC-136752 · Issue 587728
Adding handling for custom image on S3 storage space
Resolved in Pega Version 8.1.9
When using an S3 repository for Content storage, trying to create a new space with a custom image did not upload the image. Investigation showed that when attachment storage is configured as an external repository, the pyAttachStream property which is used to create the the thumbnail was getting cleaned as part of the saving logic. This has been resolved by adding an update that will hold the attachStream value in a local property before calling attachment save.
INC-141920 · Issue 595139
Unable to delete the Spaces after loggin off
Resolved in Pega Version 8.1.9
If a Space was created and then deleted in the same login session, the delete worked as expected. If the Space was created and then actions were taken to delete it on a subsequent login, the Space was not actually deleted. Investigation showed this was due to v8.1 not having a stream/blob (PZPVSTREAM) in the pc_work_group table, and this behavior was the result of extra properties included on the page. To resolve this, the extra properties on the page will be removed before the obj-save/commit .
SR-D85624 · Issue 552697
Corrected Microsoft Internet Explorer displaying checkboxes as sliders
Resolved in Pega Version 8.1.9
Checkboxes were displaying as sliders in Microsoft Internet Explorer version11.1304.17134.0 due to Microsoft Internet Explorer returning Table pc 2.0. Since Pega HTML class includes tablet, .tablet related styles were getting picked up and displaying the checkboxes in tablet mode. To resolve this, a check has been added to pyIsTablet to evaluate correctly at runtime.
SR-D91532 · Issue 556406
Resolved Clear Cache error for mobile client
Resolved in Pega Version 8.1.9
When attempting to clear local storage while logged into the Mobile Client, the error message "You need to be able to connect to the server in order to clear the storage" appeared. This was traced to the application being configured to disable a user's web session immediately after log in, and was due to the "Clear Cache" functionality failing while attempting an AJAX request to invoke the server's "pzAmIOnline" activity. While there was a workaround of using the check box "Access group requires a connection for portions of the application", this has been resolved by updating the Settings - Clear Cache functionality in order be able to detect if it's online in a different way.
SR-D95428 · Issue 555260
Security added to retrieving operator list by URL extension
Resolved in Pega Version 8.1.9
It was possible to append information to the application URL which allowed an unauthenticated user to find a list of operators. This has been corrected, and will now result in the message "There has been an issue; please consult your system administrator."
INC-119669 · Issue 562588
Special character handling added to filters for table sourced with parameterized RD
Resolved in Pega Version 8.1.9
Filters were not working on a table when sourced with a report definition which accepted a parameter value containing special characters (Eg: S&P). This has been resolved by using StringUtils.reversibleCrossScriptingFilter in the pzGetGridColUniqueValues activity to allow filters to contain special characters.
INC-145810 · Issue 599463
BIX log shows correct corrupted BLOB pzInskey
Resolved in Pega Version 8.1.9
An update has ben made to ensure the correct inskey is shown in the BIX logs for a corrupted BLOB.
SR-D90400 · Issue 563187
Explicit parent added for descendants in subreport to correct summary
Resolved in Pega Version 8.1.9
When using a Report Definition with a Summarize column and a subreport with join class, it was not considering implementation class work objects. As a result, the prepared values were only partially computed. This was traced to the SubReport in SetQuery not having reference to a parent for the descendants classes, and has been resolved by explicitly setting the parent value.