SR-B12770 · Issue 285068
Text areas display OOB error message as expected
Resolved in Pega Version 7.3
In the Text area control, the Pega OOB error message was not generated when there was no value in the required text area. This was an issue with minimum characters validation not considering an empty string to be a valid one, and has been corrected.
SR-B13315 · Issue 284499
Accessibility updated for flow action label
Resolved in Pega Version 7.3
Accessibility tools such as JAWS were not reading out the flow action label. This has been fixed.
SR-B13315 · Issue 284499
Accessibility updated for flow action label
Resolved in Pega Version 7.3
Accessibility tools such as JAWS were not reading out the flow action label. This has been fixed.
SR-B13450 · Issue 284622
Null check added to joins of UserWorkList columns
Resolved in Pega Version 7.3
When attempting to join a pyUserWorkList Report definition with work class properties, blank values in the pyUserWorkList columns caused a Null Pointer exception on click of the filter icon for joined class properties/columns. This has been resolved by adding a null check.
SR-B13517 · Issue 293343
Icon alignment fixed in grids with skin inheritance
Resolved in Pega Version 7.3
The Header Title and the Collapsible Icon of a grid were misaligned due to an error in skin inheritance. The pzTemplateNewSkin1 legacy standard format has been changed to correct this.
SR-B14210 · Issue 284725
Autocomplete updated to handle null resultcount from data page
Resolved in Pega Version 7.3
The autocomplete control was not rendering a list supplied by data page results due to the pxResultCount being null in the results of the datapage. The count size calculation in the autocomplete function has been reworked to resolve this.
SR-B14416 · Issue 289018
Fixed double actions on repeat layout
Resolved in Pega Version 7.3
In a Grid Repeat Layout, actions added on the event 'Enter' were automatically added to event 'Click' and resulted in double actions at the runtime. This was an issue with the system incorrectly setting the pyKeyCode in pzGridActionSets Activity, and has been fixed.
SR-B14432 · Issue 286451
Editability check added to asterisk symbol (mandatory field expression) display
Resolved in Pega Version 7.3
Sections using conditional read-only and editable modes displayed the mandatory expression (asterisk symbol) in both modes. To correct this unexpected behavior, the GenerateLabelCellContent RUF has been updated to check whether the control is editable and only generate the asterisk if the result is true.
SR-B1478 · Issue 274489
Better handling for empty LockInfo page
Resolved in Pega Version 7.3
Intermittent errors were encountered when attempting to expand rows of a repeat grid. This was due to handling difference related to a pre-condition check for the LockInfo page used to create error messages. Since the LockInfo page is not required or consistently used, the system has been updated to better handle cases where it is empty.
SR-B15575 · Issue 285206
Accessibility added to flow action label
Resolved in Pega Version 7.3
When an accessibility tool such as JAWS was used, the flow action label was not read out and no indication was given regarding what action was expected. To correct this, the RUF pzGenerateControl has been updated to add tabindex=0 so the section heading can be read out by accessibility tools.