INC-147658 · Issue 604684
Handling added for Top and Primary page references in flow action
Resolved in Pega Version 8.5.2
Handling added for Top and Primary page references in flow actionAfter upgrade, if a flow action had a class of the section which was different from the class of the flow action, the DXAPI code retrieved the section as the same class of the flow action and not the class defined in the flow action. In flow action, the section was configured be rendered in the context of page reference as Top, however, this was not handled so the section was resolved in the context of primary page. This has been resolved by adding the missing handling for Top and Primary page references in flow action.
INC-148817 · Issue 604969
Added check for ABAC policy to getassignmentdetailsinternal
Resolved in Pega Version 8.5.2
When an attribute based access control (ABAC) policy was defined on a particular class, the policy was properly applied when browsing instances of the class and directly opening the work object. However when an associated assignment was processed via the DXAPI (using the assignments service) the security was not applied and users who should not have access were able to progress the case. This has been resolved by adding a check in the pzgetassignmentdetailsinternal activity to check for work object opening security.
INC-149823 · Issue 608352
DX API returns properly referenced icon class for embedded page
Resolved in Pega Version 8.5.2
When using the DX API to build an Angular JS UI, the response returned from the GET /cases/{ID}/actions/{actionID} api did not return the iconStyle for an icon class that uses a property reference when the flow is on an embedded page. This has been resolved by adding code to set the correct context for pzAPICreateJsonForModes and pzAPICreateJsonForField Rule-Utility-Function.
SR-A4171 · Issue 213701
Added keyword support for <current>
Resolved in Pega Version 7.2
Variations between system versions were causing a decision table containing some regexp functions to pass or fail validation depending on the version. To remedy this, support has been added for using the regular expression function as a keyword to ensure valid tables are properly handled.
SR-A5565 · Issue 217722
Added missing filename encoding for drag and drop
Resolved in Pega Version 7.2
An error was being generated when opening an attached file with "$" in the filename. This was due to missing encoding for cases attached with drag and drop, and has been corrected.
SR-130442 · Issue 212468
Added support for localization of the 'Advanced' value of the When rule
Resolved in Pega Version 7.2
If the "Advanced" value was localized in the When rule form, it failed as it was trying to compare with localized text. To resolve this, WhenTabListener has been modified to use the ID attribute instead of text for comparison.
SR-A6520 · Issue 216004
Case Worker Portal harness error resolved
Resolved in Pega Version 7.2
When using the Case Worker Portal with the UI-Kit:03-01-01 ruleset, the first search for work returned the expected results, but opening a work object and then searching again caused the same (now incorrect) results to be returned. This was traced to a harness call and storage issue, and has been resolved.
SR-A7369 · Issue 217460
Clarified evaluation order for conditional Local Actions in GetNextWork
Resolved in Pega Version 7.2
If Local Actions were configured with 'when' rules on the stages tab of a case type rule, the 'when' rules were being evaluated before assignment via GetNextWork and the wrong local actions were presented. In order to ensure flow actions are evaluated in the proper order, GetNextWork will populate a flow action before moving it to the worklist.
SR-A8396 · Issue 210609
Corrected duplicate work object IDs
Resolved in Pega Version 7.2
The out-of-the-box section pyAssignmentListGadget was generating duplicate work object ids when pyAssignmentsLabel was used to display the case/Assignments label & ID in Case contents. This was caused by changes made in a previous version intending to enhance the displaying of labels, and has been modified to avoid duplicate work object IDs.
SR-A7590 · Issue 216110
Corrected parameter page used when Flowproblems restarts
Resolved in Pega Version 7.2
Restarting the problem flow was not taking the mandatory parameters defined in the flow, instead generating the error "Required parameter Parameter_name." To correct this, the flow method body has been modified to populate the parameter page from the pyFlowParameters page before checking for mandatory parameters.