INC-160485 · Issue 655296
Trailing "/" added to public links for SSO use
Resolved in Pega Version 8.5.5
Links generated using pyWorkLinkWithLabel were not working with SSO due to not having a trailing "/" on the URL. This has been corrected by adding code to append the "/" if the public link url doesn't end with it.
INC-178148 · Issue 660926
Handling added for SSO servlet name
Resolved in Pega Version 8.5.5
After update, logging into an external site was not working correctly due to the SSO URL being appended with "/app/default". This has been resolved by updating the code to handle the servlet name properly.
SR-D46681 · Issue 514435
SnapStart supports SAML2 Authentication
Resolved in Pega Version 8.1.8
When using an HTTP Post to SnapStart into Pega using PRCustom style or PRAuth style SAML authentication, the login was looping back to the login request. Investigation showed that the Pega ACS was posting data properly back to the RelayState URL, however the login activity was not getting the SAMLResponse and simply sent a SAML Login Request again. This has been fixed by updating reqContextURI in case of SAML2 Authentication service so pyActivity=value will be passed.
INC-174267 · Issue 657129
Wait action persists when using Urgency Adjustment
Resolved in Pega Version 8.5.5
When using the Urgency Adjustment (pyAdjustAssignmentsla standard local action), once a case reached the wait action and the goal and deadline were updated the previous pyWaitAction was not being stored. This has been resolved by ensuring the previous pyWaitAction will be stored and passed to the AddAssign activity.
INC-176112 · Issue 656971
When rule inside a loop correctly picked
Resolved in Pega Version 8.5.5
While using a 'when' rule inside a loop of a page list, the rule was not being picked during runtime. This has been resolved by adding an update to allow an assembly time class name to be passed into runtime.
SR-D53176 · Issue 541793
Error when adding function filter will persist
Resolved in Pega Version 8.1.8
When an exception occurred while adding a filter in the report viewer, the error was shown but cleared due to an immediate refresh of the parent section. Analysis found that step2 of pzGetFiltersFromContent was failing, after which the error was shown, the section reload happened, and the error disappeared. To resolve the error being cleared prematurely, the pzOnLoadReloadReport control has been modified so that when there are messages on the top level page (pyReportContentPage), a parameter will be set on HarnessContextMgr to not to clear them during the next refresh call.
INC-175630 · Issue 653862
Application selections only announced when visible
Resolved in Pega Version 8.5.5
The elements of the application switcher were being announced by the NVDA screen reader even when toggled off, i.e. not visible. The issue was occurring because the focus was remaining at the search bar even after closing the app switcher window, and has been resolved by adding the necessary logic to switch the focus.
SR-D60447 · Issue 522751
Corrected unexpected save warning when switching tabs
Resolved in Pega Version 8.1.8
When using the Interaction Portal, entering case data on one open tab and then switching to another open tab caused the system to display a Save warning message as though the Tab has been closed instead of switched. This has been resolved by updating the system to skip the dirty alert when bPrompt is false in the Ajax Container container case.
INC-169636 · Issue 659533
Navigation icons added for use in offline mobile
Resolved in Pega Version 8.5.5
When using an offline mobile app, clicking on an image / link on the home page for navigation resulted in the error “Resource missing. See client logs.” This was traced to a missed use case that resulted in some icons not being available in the package, and has been corrected by including the following:webwb/py-menu-toggle.png webwb/pzgrid_downarrow.png webwb/pymenuleftarrow.png webwb/pymenurightarrow.png webwb/pymodal_mask_img.png webwb/py-grid-sort-down.svg
SR-D76134 · Issue 542160
"Offline" icon shows when simulating offline mode
Resolved in Pega Version 8.1.8