SR-D86274 · Issue 552507

Resolved validation conflict with error message display

Resolved in Pega Version 8.3.3

Error messages set through property-set- messages or edit validate were disappearing when out of focus from the date field if the field had a mandatory condition. This was traced to an edge condition where required validation was conflicting with another error message, and has been resolved by modifying the code so the system will not validate required on blur if the input has another error message.

SR-D80916 · Issue 544966

Special characters encoded to resolve Tomcat error

Resolved in Pega Version 8.3.3

When hitting down-arrow in a subprocess shape's "flow name" box, the error "Server Error, status = 400" appeared on screen. Investigation showed this was caused by Tomcat rejecting any request it considered to have unsafe characters. To resolve this, encodeURI will be used on the query string in the HTTP wrapper of the smartprompt, to encode the query string.

SR-D77557 · Issue 544682

Support added for custom portal with temporary work object

Resolved in Pega Version 8.3.3

After creating a screen flow with temporary work object in a custom portal, entering some data and clicking caused the screen to be blank after browser refresh. The same process from Designer Studio or the Case Manager portal worked as expected. Investigation showed that SPA applications with displayonpage actions was sending empty parameters to render the harness due to the 'doUiAction' activity clearing additional pages for single frame portals. To resolve this, the 'when' rule in step14 has been updated to support a custom portal and temporary work object.

SR-D61560 · Issue 539471

Support added for multiselect control with SmartTip for iPad

Resolved in Pega Version 8.3.3

When using a multiselect list control to a lproperty with Smart Tip configured, choosing one item on an iPad and then trying to tap or drag down the vertical scrollbar caused all listed items to disappear. To resolve this, the multiselect control has been updated to handle the popover exit on smart popover hover along with arrow key navigation support for tablets.

INC-167606 · Issue 665869

Updated ConfirmHarness handling for case type creation

Resolved in Pega Version 8.6.2

If a new case type was created with the initialization stage and there were no assignments in the case type, the /cases API did not return a NextPageID in response. This has been resolved by setting the pyConfirmHarness parameter before calling addworkobject.

INC-168368 · Issue 651079

Correct flow actions loaded in multi-thread portal refresh

Resolved in Pega Version 8.6.2

The member authentication screen was displaying an incorrect flow action on doing browser refresh after creating a new interaction. Refresh is a special case where the parameter retention is different across single-threaded & multi-threaded portals alongside the execution order of activities. In this case, this inconsistency occurred in a multi-threaded portal when newAssignPage had the information to load the proper assignment but the parameter indicated an old index. This has been resolved by adding 'when' conditions to to populate and pass the correct references and labels and to honor the Param.TaskIndex set and sent by UI activities so it's retained in case of multi-thread portals.

INC-171842 · Issue 664387

Visible element populated for field value controls

Resolved in Pega Version 8.6.2

When implementing a section which had several labels with visible when conditions, this is not reflected in the DX API Get Assignment View. This has been resolved by adding a visible element.

INC-173068 · Issue 654067

HTML tags escaped in Audit History field values

Resolved in Pega Version 8.6.2

The case narrative section was showing case statuses with encoded special characters such as % or ( ), resulting in entries such as "Status changed to Complete &# 40;approved& #41; !@#$ %^& amp;*&# 40;&# 41;_&# 43;.". This has been resolved by updating the PyMemo field from type Text Input to DisplayAsLiteral for case narrative, which matches the setting for case history.

INC-174267 · Issue 669672

Wait action persists when using Urgency Adjustment

Resolved in Pega Version 8.6.2

When using the Urgency Adjustment (pyAdjustAssignmentsla standard local action), once a case reached the wait action and the goal and deadline were updated the previous pyWaitAction was not being stored. This has been resolved by ensuring the previous pyWaitAction will be stored and passed to the AddAssign activity.

INC-176952 · Issue 660482

DateTime format check added for REST response

Resolved in Pega Version 8.6.2

While retrieving case details using the standard GetCases API, a datetime field defined on a work object was returned in JSON date format i.e. "QuoteExpiryDate": "2021-06-09T14:00:00.000Z". However when the same field was mapped to a flow action's section, the value was retrieved by the GetAssignmentAction API which returned the value in Pega's date format, "value": "20210609T140000.000 GMT". This was traced to a missed datetime format check in the REST response, and has been resolved by using the Rule-Utility-Function pzAPICreateJsonForField to handle the conversion of the time stamp to JSON format.