Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

INC-199817 · Issue 690109

Corrected decimal handling in integer control

Resolved in Pega Version 8.6.3

An integer property was accepting decimal values on screen and not throwing default integer validation errors. In addition, the place holders shown on the integer controls on the screen were decimal values. This has been resolved by restricting the decimal values for the integer control with integer property, modifying the code for restricting decimal values for integer field, and updating the code for showing the integer placeholder for integer field.

INC-199953 · Issue 695419

Updated Document-StateTracker reset

Resolved in Pega Version 8.6.3

An unexpected performance issue was seen after refreshing a case. This was traced to the Document-StateTracker taking longer than expected to reset from "busy" to "none", often reaching the 70 second max timeout setting, and has been resolved by calling setNavigationDone so that the document-statetracker dom element updates back to "none" immediately.

INC-199989 · Issue 692578

Flow action modal pop-up closes after submit

Resolved in Pega Version 8.6.3

On clicking Submit button on the modal window, the post action was successfully completed but the buttons froze and the modal window did not close. This was traced to a missing condition in the if loop to handle the needed flow action logic, and has been corrected.

INC-200952 · Issue 691209

Added check for page current index before refetching

Resolved in Pega Version 8.6.3

When using Refresh in a table, the error "The page index "-1" specified for this RDB call is invalid; it is not zero or a positive integer" was generated. This was caused by updateFilteringState modifying the pyCurrentPageIndex value for refetching even though refetching is not required if pyCurrentPageIndex is already 1, and has been resolved by adding a check for page current index and only refetching if it does not equal 1.

INC-201372 · Issue 694015

Accessibility improvements for Cosmos Case Life Cycle

Resolved in Pega Version 8.6.3

Keyboard navigation has been updated to improve accessibility for the case life cycle component. For the "Show stages with expandable steps" configuration, code has been added to hide the steps container when tabbing through the stages. For the "Show stages with steps as overlay" configuration, the "Use form navigation (by tab)" option has been enabled for every repeating dynamic layer inside the steps overlay.

INC-201739 · Issue 694505

Switch from Pega base64 utility to java.util.Base64.getEncoder

Resolved in Pega Version 8.6.3

An on-premises Web Application Firewall (WAF) was interpreting the characters "%0a" in the Pega auto-generated URL as an "HTTP Response Splitting" attack. As a result communications were intercepted and a 403-error screen was shown. In addition, the characters %250A were interpreted as LF (line feed) or \n in the refreshFor hash generation. To resolve this, an update has been made to use java.util.Base64.getEncoder().encodeToString instead of the Pega base64 utility.

INC-201929 · Issue 692850

Removed incorrect field validation errors

Resolved in Pega Version 8.6.3

When integer controls in a section were configured as required field, clicking on the field but not entering any value resulted in the prompt for the required field validation "Value cannot be blank", and any attempts to add a positive integer using number keypad after that resulted in the repeated validation error. This has been resolved by updating pzpega_control_textinput.

INC-202218 · Issue 692877

Input from Microsoft Windows keyboard numpad enabled

Resolved in Pega Version 8.6.3

After entering a currency amount using the right side number pad keys on a Microsoft Windows keyboard, a mandatory field validation was being thrown on what appeared to be a correct input. This was due to an if condition in the keyup function that caused entries from the right side number keys to not be considered as input, and has been resolved by removing the condition from the pzpega_control_textinput file.

INC-205566 · Issue 697058

Ensured correct context for multi-select

Resolved in Pega Version 8.6.3

When using multi-select controls, there was an intermittent issue with selecting values using a mouse click. Using the tab key worked as expected. This was traced to the focus being event triggered multiple times so pega.ctx.dom returned undefined values in the second call.This has been resolved by focusing the target element before creation of capsule to ensure the context remains the same.

INC-206485 · Issue 698399

DOM Purifier updated to allow new tags

Resolved in Pega Version 8.6.3

Snippets were visible after being added and published, but after editing the same content ID it was converted to a text file. This was traced to the DOM Purifier plugin removing tags which were not in default list, and has been resolved by adding the ADD_TAGS option in the DOM purifier to accept tags.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us