INC-174694 · Issue 650780
Check added to ensure read locks are released
Resolved in Pega Version 8.5.5
Read locks were not being properly released if a thread was holding a read lock and the system encountered an issue such as an out of memory condition. To resolve this, an update has been made to DeclarativePageDefinitionCacheImpl which will check whether a thread holds any read lock before trying to acquire a write lock, and if so release all the read locks held by that thread.
INC-175343 · Issue 655351
Invalid date handling added to Legacy Adapters
Resolved in Pega Version 8.5.5
Running the Job Scheduler activity failed with the error "not a valid date/time value". Investigation showed this was caused by LegacyPropertyAdapter.isEmpty being returned as true in case of properties having invalid values, and has been resolved by adding handling for an InvalidValueException in LegacyPropertyAdapter and LegacyPageAdapter.
INC-176112 · Issue 656971
When rule inside a loop correctly picked
Resolved in Pega Version 8.5.5
While using a 'when' rule inside a loop of a page list, the rule was not being picked during runtime. This has been resolved by adding an update to allow an assembly time class name to be passed into runtime.
INC-176903 · Issue 664988
Ready to process records count correctly displayed
Resolved in Pega Version 8.5.5
After update, the QP's ready to process records count was always shown as zero in the Admin studio QP landing page. This was traced to a missing sListMaxResultCount property in the SQL query for qp-partition retrieval; this has been added, and the default value has been changed from 0 to -1 for proper interpretation of results.
INC-177773 · Issue 665336
Tracer protections updated
Resolved in Pega Version 8.5.5
Cross-site scripting protections have been updated for Tracer.
INC-177993 · Issue 657199
Archival IndexManagerService performance improved for very large tables
Resolved in Pega Version 8.5.5
Archival IndexManagerService was taking an excessive amount of time to run updateStatusForCasesWithInconsistentArchiveStatus(), a method which checks the parent case's archival status and compares it to all its children (cases & dependencies) statuses and flags parent cases with statuses that do not match. This check is done on all parent case instances that are in the indexer stage, and intermittently timed out and failed on a pr_metadata table containing over 5,000,000 records. This has been resolved by splitting the inconsistent check into smaller tasks and addressing potential parent/child/dependency relationships that can occur in the pr_metadata table.
INC-178148 · Issue 660926
Handling added for SSO servlet name
Resolved in Pega Version 8.5.5
After update, logging into an external site was not working correctly due to the SSO URL being appended with "/app/default". This has been resolved by updating the code to handle the servlet name properly.
INC-178923 · Issue 660887
Resolved startup error related to business calendar object
Resolved in Pega Version 8.5.5
An error recorded in the log file when the server started was traced to a cache update that removed the old business calendar object and added the new business calendar object to the business cal list. This has been resolved by updating the system to replace the business calendar object instead of removing the old one from the cache first.
INC-179025 · Issue 665544
Null check added for getTargetNodeUUID
Resolved in Pega Version 8.5.5
A null pointer error was seen from the tracer during a security scan. This has been resolved with the addition of a null check for TracerRequest.getTargetNodeUUID.
INC-179167 · Issue 659592
Atmosphere update
Resolved in Pega Version 8.5.5