SR-D86200 · Issue 549030
Resolved tab appearance issues related to resolution support
Resolved in Pega Version 8.3.3
When trying to add multiple tabs on larger screens, once the first row was filled with tabs then new tabs began appearing at the bottom of the layout group. The layout group worked as expected with the tab overflow having the right and left arrows with the dropdown on smaller screens. In addition, @1440px the overflow arrow on the right side was not working correctly, showing as grayed out even though focus was not on the last tab. These issues were traced to taboverflow with add icon not working correctly at certain resolutions. To resolve this, the todisableslide function has been updated to consider add icon width and layoutgroup has been updated to consider parent width.
SR-D84180 · Issue 550228
Resolved tab appearance issues related to resolution support
Resolved in Pega Version 8.3.3
When trying to add multiple tabs on larger screens, once the first row was filled with tabs then new tabs began appearing at the bottom of the layout group. The layout group worked as expected with the tab overflow having the right and left arrows with the dropdown on smaller screens. In addition, @1440px the overflow arrow on the right side was not working correctly, showing as grayed out even though focus was not on the last tab. These issues were traced to taboverflow with add icon not working correctly at certain resolutions. To resolve this, the todisableslide function has been updated to consider add icon width and layoutgroup has been updated to consider parent width.
SR-D86274 · Issue 552507
Resolved validation conflict with error message display
Resolved in Pega Version 8.3.3
Error messages set through property-set- messages or edit validate were disappearing when out of focus from the date field if the field had a mandatory condition. This was traced to an edge condition where required validation was conflicting with another error message, and has been resolved by modifying the code so the system will not validate required on blur if the input has another error message.
SR-D80916 · Issue 544966
Special characters encoded to resolve Tomcat error
Resolved in Pega Version 8.3.3
When hitting down-arrow in a subprocess shape's "flow name" box, the error "Server Error, status = 400" appeared on screen. Investigation showed this was caused by Tomcat rejecting any request it considered to have unsafe characters. To resolve this, encodeURI will be used on the query string in the HTTP wrapper of the smartprompt, to encode the query string.
SR-D77557 · Issue 544682
Support added for custom portal with temporary work object
Resolved in Pega Version 8.3.3
After creating a screen flow with temporary work object in a custom portal, entering some data and clicking caused the screen to be blank after browser refresh. The same process from Designer Studio or the Case Manager portal worked as expected. Investigation showed that SPA applications with displayonpage actions was sending empty parameters to render the harness due to the 'doUiAction' activity clearing additional pages for single frame portals. To resolve this, the 'when' rule in step14 has been updated to support a custom portal and temporary work object.
SR-D61560 · Issue 539471
Support added for multiselect control with SmartTip for iPad
Resolved in Pega Version 8.3.3
When using a multiselect list control to a lproperty with Smart Tip configured, choosing one item on an iPad and then trying to tap or drag down the vertical scrollbar caused all listed items to disappear. To resolve this, the multiselect control has been updated to handle the popover exit on smart popover hover along with arrow key navigation support for tablets.
SR-D53176 · Issue 541796
Error when adding function filter will persist
Resolved in Pega Version 8.4.1
When an exception occurred while adding a filter in the report viewer, the error was shown but cleared due to an immediate refresh of the parent section. Analysis found that step2 of pzGetFiltersFromContent was failing, after which the error was shown, the section reload happened, and the error disappeared. To resolve the error being cleared prematurely, the pzOnLoadReloadReport control has been modified so that when there are messages on the top level page (pyReportContentPage), a parameter will be set on HarnessContextMgr to not to clear them during the next refresh call.
SR-D64231 · Issue 539235
Export to Excel cell style control added
Resolved in Pega Version 8.4.1
If a column was formatted with an auto generated numeric control, a new cell style was generated for every row during the export to Excel process. Since there is a limit on the amount of cell styles, once the number of rows in the file was greater than 64000 an error was generated. To resolve this, the system will disable the creation of a new cell style for every instance when an auto-generated numeric control is used.
SR-D65327 · Issue 534572
Backspace keydown handler updated for all textinput modes
Resolved in Pega Version 8.4.1
Attempting to use the Backspace key to remove input from a number cell (either Integer or Decimal) did not work. When the action was performed by a Manager, the Backspace key works as expected. Investigation showed the logic in the keydown handler for the backspace key in pega_report_events.js was only ignoring the e.preventDefault() call when the textinput node type was text, not number or other input types. To correct this, the keydown handler has been updated so the backspace key in pega_report_events.js maintains the default backspace functionality for all textinput modes, not just those of type 'text'.
SR-D69098 · Issue 534043
Export to Excel works for for report definition with duplicate columns
Resolved in Pega Version 8.4.1
After adding a date column to a report definition (2nd column in the report), the data displayed correctly in the UI but Export to Excel failed with the error "Section 'pzRDExportWrapper' execution error on page '' of class 'Rule-Obj-Report-Definition'. : The Reference .pyDateValue(2) is not valid." This was traced to an out of bounds exception thrown if there were two or more columns with the same calculation. When preparing for export, the column with the duplicate calculation would not get added to the map of report UI fields. To resolve this, the system has been updated to allow report definition columns with the same calculation to be properly mapped to a UI field.