INC-197358 · Issue 695309
Resolved finish assignment screen freeze
Resolved in Pega Version 8.6.3
In some assignments of several flows, when the processing was done (finish assignment) the screen only displayed the loading logo. The only way to proceed was by refreshing the browser. The browser console showed the error "Uncaught TypeError: Cannot read properties of null (reading 'undefined') at setTargetValuesSuccess (expression_calculation_1480665478.js!!.js:1) at k". The error did not occur when using Live UI privileges. This has been resolved by updating the expression calculation.
INC-197358 · Issue 695308
Resolved finish assignment screen freeze
Resolved in Pega Version 8.7.1
In some assignments of several flows, when the processing was done (finish assignment) the screen only displayed the loading logo. The only way to proceed was by refreshing the browser. The browser console showed the error "Uncaught TypeError: Cannot read properties of null (reading 'undefined') at setTargetValuesSuccess (expression_calculation_1480665478.js!!.js:1) at k". The error did not occur when using Live UI privileges. This has been resolved by updating the expression calculation.
SR-A3697 · Issue 210718
Resolved Revalidate and Save freeze
Resolved in Pega Version 7.1.9
After upgrade, running revalidate and save on imported rules with the option "During Update Move To?" enabled, the first rule was processed but the process then stopped and generated the error "Uncaught TypeError: parentRow.all is not a function" if the Google Chrome or Mozilla browser is used. This problem was caused by old non-auto-generated controls, and has been resolved by modifying the ShowBulkUpdateList html section.
INC-202480 · Issue 699080
Resolved report filter section freeze
Resolved in Pega Version 8.5.6
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
INC-202480 · Issue 699082
Resolved report filter section freeze
Resolved in Pega Version 8.6.4
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
INC-202480 · Issue 711699
Resolved report filter section freeze
Resolved in Pega Version 8.7.2
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
INC-202480 · Issue 699081
Resolved report filter section freeze
Resolved in Pega Version 8.8
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
SR-A1959 · Issue 209485
Corrected checkbox behavior with freeze header
Resolved in Pega Version 7.1.9
In repeat grids where freeze header was checked throughout the application and data was populated by page list, running the flow on selecting a check box for a single row resulted in all the check-boxes of the grid getting selected. This was an issue where the API "checkAllIfInHeader" incorrectly assumed that the checkbox was in the header for each row, which caused all the checkboxes of the row to change according to the checkbox that had been changed. To prevent this, a condition has been added to "checkAllIfInHeader" to exit if it is inside a row and not in the header.
SR-B70379 · Issue 326388
Post-printing screenshot window freeze fixed
Resolved in Pega Version 7.3.1
When an attached screenshot was clicked open and displayed in a pop-up window, the window was freezing after a print operation was performed. This was an issue with closing the ActiveX control through Microsoft Internet Explorer. To resolve this, the ActiveX control previously used has been changed to Silverlight.
INC-164631 · Issue 641441
Updated Ajax container close to resolve intermittent portal freeze
Resolved in Pega Version 8.4.5
The portal was intermittently freezing after the "+" icon was clicked to create a new case from the Create menu. This was traced to the Ajax container not closing after creation of the create modal, and has been resolved.