Back Forward Connect Request Processor form
Completing the Dequeuing Options tab

About Connector Request Processor data instances

5.5 Use this tab to instruct the Pega-IntSvcs agent how to handle the connector requests stored in the queues defined on the Queuing Options tab.

Field

Description

Maximum number of
execution attempts

Specify how many times the Pega-IntSvcs agent is to attempt to process the connector request. Typically, set this value to more than 1 so the agent can try again if the request fails the first time (perhaps a work object was locked, for example).

Keep in queue after all
execution attempts failed

Select if you want to keep a connector request in the queue after the Pega-IntSvcs agent has tried to run the request the number of times specified in the Maximum number field and it fails. Clear if you want to delete failed service requests from the queue.

Requests that fail more than the limit in the Maximum number of
execution attempts
field are known as broken queue items. An administrator can review and update these with a report from the > Process and Rules > Tools > Work Admin > Broken Queue Items menu selection. BYRNB 3/1/10

Keep in queue after
successful execution

Select if you want to keep a service request object in the queue after it was successfully processed.

Up About Connect Requestor Processor data instances