Tracer
|
Do not attempt to start the Tracer when another requestor session on the same Process Commander node, using the same Operator ID, is running the Tracer. KENDM 2/2007
Ordinarily, Process Commander uses HTTP compression to reduce the length of text messages sent to Internet Explorer. HTTP compression is also used in SOAP messages. This may complicate Tracer debugging, as it is difficult to interpret the messages.
To disable HTTP compression, edit the prconfig.xml
file
and adjust the value of the Tracer setting
enable-compression
setting to false. This change takes
effect the next time your system starts. B-3254
Reset this value to enable compression when debugging is complete.
B-13160In some Process Commander installations, the
ClientHostName
value appears only as a numeric Internet
Protocol address. The true ClientHostName
is visible only
when the application server is enabled to perform Domain Name Server
lookups:
enableLookups
(in the server.xml
file) to
"true" to allow DNS lookups.ReverseDNSAllowed="true"
to the
config.xml