You can enable search by using Dynamic System Settings.
Dynamic System Setting | Default | Description |
---|---|---|
indexing/distributed/transport/port | 9300-9400 |
Enables communication between nodes. Open a TCP port for each node in a Pega 7 Platform cluster and make each port available for the indexing engine to use (for internal node-to-node communications only). |
indexing/distributed/batch/numworkers | 2 |
Controls the number of threads on each node that process entries in the search queue during bulk indexing operations such as clicking the Re-Index button on the Search landing page. |
indexing/distributed/search_timeout_millis | None |
Sets a search query time-out limit in milliseconds. |
indexing/distributed/masternode_discovery_timeout_millis | 30 |
Sets the time-out to wait in milliseconds, for all nodes of a cluster, checking for an index node to become available during the startup process. If an index node is not available, the node starts after the time-out; it does not wait for the indexing node to become available. Node initialization synchronizes the nodes once the indexing node is available. |
alerts/search/operationtime_threshold | None |
Generates alerts for search queries whose response time, in milliseconds, exceeds the specified threshold. |
indexing/distributed/enable_inter_node_encryption | false | Specifies whether encryption and authentication are enabled for communication among search nodes. |
indexing/distributed/enable_onlyselectedfieldsinfulltextsearch | false | Specifies whether to include only those properties with the Make this property available for full-text search option selected on the relevant Custom Search Properties instance. |
indexing/distributed/search/displaySecuredProperties | false | Specifies whether to include properties with access control policies in search results. |
In the Short description field, enter a short description.
In the Owning Ruleset field, enter the owning ruleset, for example, Pega-RulesEngine
In the Setting purpose field, enter the setting as shown in the preceeding table. For example indexing/distributed/batch/numworkers
Click Create and open.
In the Value field, enter the value. For example, 3
Click Save.