Security policies settings

You can configure security policies settings to authenticate users and manage sessions.

Table 1. Password policies settings
Policy Notes Default value Min value Max value
Minimum operator identifier (ID) length   8 3 64
Minimum operator password length   8 3 64
Minimum numeric [0-9] characters required in operator password   1 0 64
Minimum alphabetic [a-z, A-Z] characters required in operator password   1 0 64
Minimum lowercase [a-z] characters required in operator password   0 0 64
Minimum uppercase [A-Z] characters required in operator password   0 0 64
Minimum special characters required in operator password Available special characters include: ` ~ ! @ # $ % ^ & * ( ) _ + - = { } [ ] | \ : " ; ' < >? , . / 1 0 64
Maximum unique historical operator passwords If the value is 5, you cannot change your password to match any of the most recent five passwords that you used. 5 0 128
Maximum operator password age in days The maximum number of days before an operator must change the password.

If you set the value to 0, the password never expires. To set an expiration period for a password, select a value between 1 and 128.

30 0 128
Minimum operator password age in days The minimum number of days before an operator can change the password. 0 0 128
Minimum number of different characters between current and new operator passwords Minimum number of characters that should be different between the current password and the new password when changing the password. 0 0 64
Table 2. CAPTCHA policies settings
Policy Notes Default value Min value Max value
CAPTCHA implementation If set to Default, the system displays the CAPTCHA implementation that is included with Pega Platform.

If set to Custom, the system displays the custom CAPTCHA implementation enabled for this system. An application can use third-party CAPTCHA solutions on the application login screen. However, a certain amount of developer work is required to prepare the custom ruleset to deliver the third-party resource.

Default    
Enable CAPTCHA Reverse Turing test module If enabled, the system displays the CAPTCHA upon authentication fails, with a probability set by the following field.

If disabled, no CAPTCHA is displays even on login failure.

Enabled    
Probability that CAPTCHA will be presented upon authentication failure (%) If the CAPTCHA reverse Turing test is enabled, the percentage set here is the likelihood that the CAPTCHA is displayed. 5 0 100
Enable presentation of CAPTCHA upon initial login If enabled, the CAPTCHA is displayed the first time that the user tries to log in to a new system or from a new computer. Enabled    
Table 3. Lockout policies settings
Policy Notes Default value Min value Max value
Enable authentication lockout penalty mechanism If enabled, after n failed login attempts, the system imposes a delay of n minutes and seconds after every unsuccessful login attempt. Enabled    
Failed login attempts before employing authentication lockout penalty After the number of failed attempts set here, the user experiences a delay after each further attempt. The delay gets longer with each attempt. 30 0 128
Initial authentication lockout penalty in seconds Set the initial delay time. 8 0 128
Failed login attempts before password lockout Set the number of allowed failed login attempts before the account is locked. 0    
Password lockout duration in minutes Set the time period for which the account remains locked after the allowed failed login attempts are exceeded.
  • Set to a non-zero value if you want the account to be unlocked automatically.
  • Set to zero to require the account to be unlocked manually from the Unlock Operators landing page.
0    
Table 4. Audit policies settings
Policy Notes Default value Min value Max value
Audit log level Set the Audit log level. The options are:
  • None — No log entry is added
  • Basic — Record failed login attempts only
  • Advanced — Record failed and successful login attempts
Basic    
Table 5. Multi-factor authentication policies (using one-time password)
Policy Notes Default value Min value Max value
Maximum one-time password failure attempts Set the allowed number of failed login attempts before the one-time password becomes invalid and another one-time password must be generated. 3 1 3
Maximum age of one-time password token in seconds Specify how long a current one-time password can be used to authenticate the user before it becomes invalid and another one-time password must be generated. 30    
Validity of one-time password confirmation in minutes Specify how long a current one-time password confirmation is valid before another one-time password confirmation is required for further transactions in that session. 60    
Email account from which one-time password needs to be sent Specify an email account that is used to send one-time passwords. If necessary, click the Add icon to edit the selected email account.

If you do not define an email account or an SMS account, the multifactor authentication policy is not applied.

     
SMS account from which one-time password needs to be sent Specify an SMS account that is used to send one-time passwords. If necessary, click the Add icon to add the SMS account.

If you do not define an SMS account or an email account, the multifactor authentication policy is not applied.

     
Table 6. Operator disablement policy settings
Policy Notes Default value Min value Max value
Number of days of inactivity Specify how many days a user has to be inactive before being automatically disabled. 90 1 90
Exclusion list of operator IDs Show a list of operators who are excluded from the policy.

Click Add Operator to exclude operators from the policy.