End of support for Microsoft Internet Explorer 8 and quirks mode applications in Pega 7.1.9

Valid from Pega Version 7.1.9

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 8 in January 2016, Pega 7.1.9 does not support Internet Explorer 8, nor does it support non-HTML5 standard user interfaces.

You must upgrade to Microsoft Internet Explorer 9 or later or use Google Chrome, Apple Safari, or Mozilla Firefox. If you are using Internet Explorer 9 or later, you must turn off compatibility mode by accessing the Compatibility View settings.

Note the following:

  • Pega 7.1.9 does not support user interface rules that are not based on HTML5 standards (rules in quirks mode).
  • If you use applications that are rendered in quirks mode, which enables Pega 7 to correctly display and render non-HTML5 standard user interfaces, you must update them to standards-based HTML5 user interfaces when you upgrade to Pega 7.1.9 or later. Pega 7 provides automated tools to help you migrate your applications.
  • Pegasystems Global Customer Support will not investigate or fix any Pega 7.1.9 bugs or support requests that are exclusive to Internet Explorer 8 or quirks mode user interfaces.

You can quickly identify which components of your application user interface are not HTML5 standards-based by clicking Designer Studio > User Interface > HTML5 Application Readiness.

Upgrading to Pega 7.1.9 and a newer browser offers the following benefits:

  • These browsers are HTML5 and CSS3 compliant.
  • New features are supported and existing features work as intended.
  • The Pega 7 Platform user interface is displayed and rendered as intended.
  • Browser security is enhanced.

If you have additional questions about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

Real-time pulse processing for multinode systems

Valid from Pega Version 7.1.9

Multinode development environments now use real-time pulse processing. Previously, when a change was made on one node, the pulse processing interval could take a minute or more for that change to be reflected on another node. Now, when a rule is changed on one node, that change is immediately reflected on all the other nodes in the cluster. This change helps to ensure that users are running a rule on the same node as where the rule was changed.

Verifying that a Pega 7 Platform instance is running

Valid from Pega Version 7.1.9

You can verify whether a Pega 7 Platform instance is up and running by entering this URL: http://<<hostName:port/contextName>>/PRRestService/monitor/pingservice/ping

The Pega 7 Platform Engine responds with HTTP Response Code 200 if the instance is available. The response contains JSON text in the format { "duration":"<time in milliseconds>" }. Any other response codes or timeout indicate that the instance is unavailable.

Updated default system pulse processing settings

Valid from Pega Version 7.1.9

The default settings for system pulse processing have been updated in this release.

Upgrades to Pega 7.1.9 from a previous version of the Pega 7 Platform use database pulse by default. Database pulse synchronizes rule changes at a periodic interval across all nodes in a system.

New installations of Pega 7.1.9 use cluster-based pulse by default. Cluster-based pulse immediately updates rule changes across all nodes in a system after the changes are saved.

You can change the database pulse setting to the cluster-based pulse setting by updating the value attribute for initialization/pulse/transport to "cluster" in the prconfig.xml file or in the Dynamic System Settings. Changing from database pulse to cluster-based pulse requires a full cluster restart after the changes are made.

For more information, see Pega-RULES agents.

Database storage used for passivation in High Availability mode

Valid from Pega Version 7.1.9

When an application is running in High Availability mode, the value attribute for initialization/​persistrequestor/storage in the prconfig.xml file or the Dynamic System Settings​ now defaults to "database."

Previously, applications running in High Availability mode required shared passivation, where either initialization/​persistrequestor/storage was set to “OnTimeout” or a custom passivation mechanism was used. The change to using database by default provides persistent storage for passivation, and provides control for the landing page for High Availability.

For more information, see Understanding passivation and requestor timeouts and the High Availability Administration Guide.

PegaDISTRIBUTION Manager (PDM) is no longer available

Valid from Pega Version 7.1.9

The PegaDISTRIBUTION Manager (PDM) is no longer available in the Pega 7 Platform. The related PDN articles and help topics have been archived.

Primary key constraint error when using JBoss

Valid from Pega Version 7.1.9

A primary key constraint violation exception might occur in the following situation: you use JBoss EAP 6.4 and SQL Server 2012 with a JDBC 4 driver, and you use two or more file listeners or JMS MDB listeners with concurrent threads that create work objects that use multiple files. If a primary key constraint violation exception occurs in this situation, update the data source configuration file to set the jta parameter to true. For example, set <datasource jta="true" jndi-name-"java:/jdbc/PegaRULES>.

Specify the scope for rolling back rules and data to a restore point

Valid from Pega Version 8.4

Create restore points to save the state of all rules and data in your system at a significant point in time, for example, before you import an application. Roll back to that restore point to return the system to that state. Now, you can filter which rule and data instances are returned to their previous state:

  • System: Roll back every rule and data instance that has a history record.
  • User: Roll back rule and data instances modified by a specific user. If any rule was changed by more than one user, you will see an error message and must use the system rollback.
  • Application: Roll back rule and data instances in a specific application.

For more information, see Using restore points to enable error recovery.

Rules can no longer access Pega internal Java packages

Valid from Pega Version 8.4

You can no longer create rules that access Java packages that reference internal APIs (syntax com.pega.platform.*.internal*). This change does not affect rules that access Pega public API packages.

If you encounter issues when running existing rules that reference internal Pega APIs, contact Pega Support.

Upgrade impact

After an upgrade to 8.4 and later, clients can no longer save new or modified rules that access Pega internal APIs; existing rules that reference internal APIs can still be run but cannot be modified. 

What steps are required to update the application to be compatible with this change?

Following a software upgrade to 8.4 or later, clients can refactor existing rules into guardrail compliant rules. To find rules to refactor, run the validation tool from designer studio (Application > Tools > Validation) to identify what rules fail validation; failed rules that include the message "Test compilation failed : Illegal internal class reference : com.pega.internal.XYZ" can updated to reference appropriate APIs.

Client-server deployment of Hazelcast

Valid from Pega Version 8.4

Pega Platform now supports the client-server model for the Hazelcast service, which provides cluster communication and distributes Pega Platform features across nodes. This optional deployment model introduces independent scalability for both servers and clients in Pega Platform, improving stability for deployments that use a large number of nodes.

The Hazelcast client-server model is intended for select environments running Pega Platform 8.4 across a large number of nodes and should be deployed only when directed by Global Client Support.