EAR support for JBoss EAP 6

Valid from Pega Version 7.1.5

PRPC deployment in JBoss EAP 6 as an EAR archive is now supported. 

If you need to deploy the JBoss EAR file, go to My Support Portal and submit a Support Request. GCS can assist you with the procedure.

Small distribution kit

Valid from Pega Version 7.1.5

A new “small” release distribution format for Maintenance Levels (ML) is now available, designed to significantly increase adoption via: 

  • Minimal package size and faster download time
  • Minimal install time via tactical changes to the upgrade implementation and process

This kit contains streamlined installers (both UI and command-line installers) and specialized error handling for ML updates (for example, a “small” kit will only work if an existing version of the same release is already installed). 

The kit assembly has also been automated, which includes the construction of a PRPC_Rules.jar archive containing cumulative rules since the GA release. 

A “small” kit will work for any prior ML release within a major release (for example, the “small” ML5 distribution kit will update any customer on 7.1 ML1 through 7.1 ML4).

Improved data page performance

Valid from Pega Version 7.1.5

Improvements have been made with queueing and processing of asynchronously-loaded data pages to reduce the number of calls to the database and avoid generating performance problems because of unneeded asynchronous requests.

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

DB2-LUW database logfile size increase

Valid from Pega Version 7.1.5

This issue applies to DB2-LUW database platforms only.
 

To avoid running out of logfile space due to large transaction sets during the rule base load of a Pega 7.1.x install, upgrade, or maintenance level update, systems supported by a DB2-LUW database platform should increase the LOGFILSIZ parameter to at least 4096 pages from the default size of 1000 pages.

After the size has been increased, restart the database to ensure that the new setting is loaded into the database correctly.

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

WSDL generation error prevents invocation of SOAP services

Valid from Pega Version 8.4.2

Status

A Known Issue was introduced in the 8.4.2 Pega Platform patch release, which impacts both upgrades and new installations of that version.

Description

Due to changes introduced in the SOAP functionality for the case-mismatch error in SR-D98509/INC-119725, the WSDL is being generated for SOAP services with an incorrectly-capitalized element, which prevents the service from being invoked.  The element should be “name” instead of “Name”.

Workaround

Clients must perform the following workaround after they define a new SOAP connector in Pega Platform:

  1. To download the WSDL from Pega Platform:
    1. After using the SOAP Wizard (Dev Studio > Configure > Integration > Services > Service Wizard) the WSDL URL is shown at the bottom right of the Dev Studio screen.
    2. Click the URL to display the XML.
    3. Save the WSDL file to your local system.
  2. In the text editor of your choice, modify "Name" to "name" in every <element “name” = … > tag in the WDSL.
  3. Save your changes to the local file.
  4. To reload the WSDL into Pega Platform:
    1. In Dev Studio, open the Configure menu.
    2. Select Integration > Connectors > Create SOAP Integration.
    3. In the New SOAP integration wizard, select Upload WSDL from File.
    4. Complete the upload using the wizard prompts.

This is a design-time issue, not a run-time issue; therefore, clients only have to perform this workaround process once. Existing SOAP services should not be impacted; however, if clients modify an existing SOAP service definition by re-running the wizard, clients must reapply the workaround for Pega Platform to recognize the SOAP definition changes.  

Resolution

This issue will be addressed in the Pega Platform Patch Release 8.4.3.  Clients who upgrade to that version or later should not see this issue.