Change logic does not work in Report Editor

Valid from Pega Version 7.1.2

The Report Editor​ change logic button does not work. As a workaround, use the rule form to change the logic.

Flow rules not supported in IE8

Valid from Pega Version 7.1.1

In versions prior to 7.1.2, flow rules do not open in Internet Explorer 8 (IE8). Upgrade your system to the latest version of PRPC or access flows from another supported browser.

Additional upgrade scripts for new columns

Valid from Pega Version 7.1.4

In Version 6.2, additional columns (Major, Minor, and Patch) containing ruleset Version information were added to 15 tables in the PRPC database. When upgrading from a pre-Pega 7 release, scripts must be manually run after the upgrade to populate these columns.

These scripts are located in the Resource Kit, under Additional Upgrade Scripts.

  • If upgrading to a single schema, run both scripts.
  • If upgrading to a split schema, run the _data script against the data schema and run the _rules script against the rules schema.
  Depending upon your database type (platform) and the size of your database, these scripts may require significant time and system resources to run.

Choose the scripts for your database type:

  • db2zos_rulesetversion_columns_data.sql
  • db2zos_rulesetversion_columns_rules.sql

 

  • mssql_rulesetversion_columns_data.sql
  • mssql_rulesetversion_columns_rules.sql

 

  • oracle_rulesetversion_columns_data.sql
  • oracle_rulesetversion_columns_rules.sql

 

  • postgres_rulesetversion_columns_data.sql
  • postgres_rulesetversion_columns_rules.sql

 

  • udb_rulesetversion_columns_data.sql
  • udb_rulesetversion_columns_rules.sql

Source field not displaying in data transform

Valid from Pega Version 7.1.4

On the Data Transform rule form when using the Update Page action, if the Relation value is updated to “with values from”, the Source field will not be displayed.

(Note that for existing data transforms where the Source field has already been completed, this situation should not occur.)

Workaround

  1. Below is a data transform that has been configured to use Update Page.
    DataTransform1.jpg
  2. If a user were to choose an alternate source by updating the ‘with values from’ Relation value, they would not be prompted to provide a page name in the Source field.
    DataTransform2.jpg
  3. At this point, to be able to enter the Source page value, the user has to save the rule, which results in an error because the source page value is blank. This causes the field to appear.
    DataTransform3.jpg
  4. Once the field has appeared, the Source page value can be provided, and the form can be saved successfully.
    DataTransform4.jpg

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Slow WebSphere performance on Mac platforms

Valid from Pega Version 7.1.2

Use the following JVM setting to improve WebSphere performance on Mac platforms:

-Djava.net.preferIPv4Stack=true

Turn off saved connections in WebLogic

Valid from Pega Version 7.1.1

PRPC caches connections in thread-local storage. When using a WebLogic application server, set database/savedconnections to FALSE to avoid incorrectly saved, container-managed transactions. You can make this update through JNDI settings or by adding an entry to the prconfig.xml, for example:

<env name="database/savedconnections" value="false" />

Remove JVM settings from prior installations

Valid from Pega Version 7.1.1

JVM memory settings ​defined in the setupDatabase.properties file to support a prior installation need to be removed. 

Memory settings are now handled by the installation program. Duplicating these settings may cause installation or upgrade failures. 

Automated Unit Testing is unavailable

Valid from Pega Version 7.1.1

Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.

Starting in 7.1.6, users can access AUT features from supported browser versions of IE.

Privilege required for Recent Explorer

Valid from Pega Version 7.1.1

Users with custom roles defined must add the pxUpdateRecents privilege to see work in the Recent Items Explorer. 