Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

Update Existing Applications wizard will run for every upgrade

Valid from Pega Version 7.1.7

The upgrade process from a PRPC 5.x or 6.x system to Pega 7.1.7 now automatically runs the Update Existing Applications wizard. This may extend the time that the upgrade process takes to complete, depending on the version you are upgrading from and the number of rules in your application.

Upgrading to Pega 7.1.7 with an Oracle database requires new role permissions

Valid from Pega Version 7.1.7

When upgrading or updating from a prior version to Pega 7.1.7, if your system uses an Oracle database, an additional role is required to support the Reversability functionality. In addition to the Oracle privileges specified in the Install Guides, the role SELECT_CATALOG_ROLE is required. Verify that this role is present before beginning the upgrade or update.

Add additional columns to customized work history tables

Valid from Pega Version 7.1.6

The standard work history table, pc_history_work, contains two new columns that return the latitude and longitude coordinate location of the action that prompted the history. Mobile devices can display this location as a street address. If you have a customized work history table, add these two columns to it:

  • <decimal name="pxLatitude" size="19" scale="9"/>
  • <decimal name="pxLongitude" size="19" scale="9"/>

Action required by admins for improved search

Valid from Pega Version 7.1.7

Starting November 13, 2014, after updating to or upgrading from a prior version to Pega 7.1.7, your system administrator must manually build all indexes for Elasticsearch before the system can automatically switch from Lucene to Elasticsearch.

It is recommended that you begin this manual re-indexing process for all enabled index types as soon as your update or upgrade is complete. The search landing page refers to Elasticsearch settings; during re-indexing, however, Lucene search continues to function to ensure that there is no interruption in search functions. When planning the re-indexing, be aware that the initial re-indexing requires significant resources on the host node and can be a lengthy process, depending on the number of rules and work objects in your system.

See the Pega 7.1.7 Upgrade Guide for information about manually indexing Elasticsearch.

Run cleanup.bat/sh script only before upgrading

Valid from Pega Version 7.1.1

Prior to upgrading the rulebase, you can optionally run the cleanup.bat/sh script to remove older rules from the database.

Run this script before you upgrade your rulebase, or the script may delete needed rulesets. For more information about running the cleanup.bat/sh script, refer to the Upgrade Guide specific to your release version.

Custom database (DB) triggers are dropped during upgrade

Valid from Pega Version 7.1.8

The latest version of Pega 7 improves performance by no longer using database triggers to assist with System Pulse and Data-Rule-Summary processing, which is now done within the Pega 7 engine. As a result, DB triggers are no longer installed on either the pr_sys_updatescache or pr4_rule_vw tables.

When upgrading to the latest version of Pega 7, if you had previously implemented a custom database (DB) trigger on these tables, or a custom DB trigger that refers to these tables, it is removed during the upgrade process. No custom triggers are removed unless they reference these tables.

If you have custom DB triggers that reference the pr_sys_updatescache or pr4_rule_vw tables and perform other processing, those triggers must be reimplemented. When doing so, you must be careful to not modify the pr_sys_updatescache or pr4_rule_vw tables.

For more information, see Startup check removes custom DB triggers.

Updates no longer require redeploying the prweb.war file or the application server-specific EAR file

Valid from Pega Version 7.1.7

Updating from Pega 7.1.7 to later versions of Pega 7 no longer requires that you redeploy the prweb.war file or the application server-specific EAR file.

Note that upgrades from versions prior to Pega 7.1.7 still require that you redeploy these files.

End of support for Microsoft Internet Explorer 8 and quirks mode applications in Pega 7.1.9

Valid from Pega Version 7.1.9

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 8 in January 2016, Pega 7.1.9 does not support Internet Explorer 8, nor does it support non-HTML5 standard user interfaces.

You must upgrade to Microsoft Internet Explorer 9 or later or use Google Chrome, Apple Safari, or Mozilla Firefox. If you are using Internet Explorer 9 or later, you must turn off compatibility mode by accessing the Compatibility View settings.

Note the following:

  • Pega 7.1.9 does not support user interface rules that are not based on HTML5 standards (rules in quirks mode).
  • If you use applications that are rendered in quirks mode, which enables Pega 7 to correctly display and render non-HTML5 standard user interfaces, you must update them to standards-based HTML5 user interfaces when you upgrade to Pega 7.1.9 or later. Pega 7 provides automated tools to help you migrate your applications.
  • Pegasystems Global Customer Support will not investigate or fix any Pega 7.1.9 bugs or support requests that are exclusive to Internet Explorer 8 or quirks mode user interfaces.

You can quickly identify which components of your application user interface are not HTML5 standards-based by clicking Designer Studio > User Interface > HTML5 Application Readiness.

Upgrading to Pega 7.1.9 and a newer browser offers the following benefits:

  • These browsers are HTML5 and CSS3 compliant.
  • New features are supported and existing features work as intended.
  • The Pega 7 Platform user interface is displayed and rendered as intended.
  • Browser security is enhanced.

If you have additional questions about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

Upgrades from PRPC 5.4 or earlier fail if index/data enabled = true

Upgrades from PRPC 5.4 or earlier fail if the index/data enabled Data Admin System Setting (DASS) is set to true. To upgrade from versions prior to PRPC 5.5:

  1. Set the index/data enabled DASS to false.
  2. Perform the upgrade.
  3. Set index/data enabled to true.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us