Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Change logic does not work in Report Editor

Valid from Pega Version 7.1.2

The Report Editor​ change logic button does not work. As a workaround, use the rule form to change the logic.

Tomcat log files moved to work directory

Valid from Pega Version 7.1.2

For Tomcat application server users, the default path for PRPC logs has been changed to the "work" directory for Catalina. For example:

<tomcat>\work\Catalina\localhost\prweb

This directory can be cleaned up during administration. To avoid loss of files, you can redirect logging to a different directory after installation:

  1. Navigate to the <tomcat-home>\webapps\prweb\WEB-INF\classes directory.
  2. Open the prlogging.xml file.
  3. Locate the "appender" definitions section that contains the "@{web.tmpdir}" string
  4. Update the FileNamePattern values to point to the new directory.

For more details, refer to the “Change the default path to PRPC logs” section in the Tomcat installation guide for your database.

Slow WebSphere performance on Mac platforms

Valid from Pega Version 7.1.2

Use the following JVM setting to improve WebSphere performance on Mac platforms:

-Djava.net.preferIPv4Stack=true

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

Use "alternate database" as report source

Valid from Pega Version 7.1.6

You can opt to use the the "alternate database" identified in the Reports Database field of the Data-Admin-DB-Table instance that supports the Applies To class of a report as the source for the report. This reduces the load on the database that serves your application when you run the report.

PRServlet not required in PRPC URLs

Valid from Pega Version 7.1.6

PRServlet is no longer required in a URL when accessing PRPC. A URL typically written like this:

http://example.com/prweb/PRServlet?[QueryString]

Can instead be written like this:

http://example.com/prweb/?[QueryString]

This change is effective only for PRPC 7.1.6 and newer versions. Older versions of PRPC still require using PRServlet in a URL.

Add additional columns to customized work history tables

Valid from Pega Version 7.1.6

The standard work history table, pc_history_work, contains two new columns that return the latitude and longitude coordinate location of the action that prompted the history. Mobile devices can display this location as a street address. If you have a customized work history table, add these two columns to it:

  • <decimal name="pxLatitude" size="19" scale="9"/>
  • <decimal name="pxLongitude" size="19" scale="9"/>

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us