Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Disregard this Comet support error at startup

Pega 7.2.2 introduced real-time notifications using Comet technologies like WebSocket and long polling. WebSocket provides the best results, but both WebSocket and non-blocking long polling must be supported by your application server. If your application server does not support WebSocket and non-blocking long polling, you might see an error stack that begins with text similar to the following:

ERROR - If you have more than one Connector enabled, make sure they both use the same protocol, e.g NIO/APR or HTTP for all. If not, org.atmosphere.container.BlockingIOCometSupport will be used and cannot be changed. java.lang.IllegalStateException: Tomcat failed to detect this is a Comet application because context.xml is missing or the Http11NioProtocol Connector is not enabled. You must use the atmosphere-native-runtime dependency in order to use native Comet Support

You can disregard this message.

However, to take advantage of the improvements to real-time notifications, enable WebSocket support:

  • For IBM WebSphere Application Server Liberty Core, see your deployment guide for instructions on configuring the application server.
  • For Red Hat JBoss, see your deployment guide for instructions on enabling WebSocket support.
  • For Apache Tomcat application servers, consider upgrading to Tomcat 7.0.53 or later which supports WebSocket.

Disregard this Java script console message

Valid from Pega Version 7.2.2

Pega 7.2.2 introduced real-time notifications by using Comet technologies such as WebSocket and long polling. WebSocket provides the best results, but both WebSocket and non-blocking long polling must be supported by your application server. If your application server does not support WebSocket, you might see a JavaScript error that begins with text that is similar to the following text:

WebSocket connection to 'ws://vnbamdevapp01:8080/prweb/PRPushServlet/... Error during WebSocket handshake: Unexpected response code: 501_getWebSocket @ pzpega_ui_messaging_1802554968!!.js:1195 pzpega_ui_messaging_1802554968!!.js:3265 Websocket closed, reason: Connection was closed abnormally (that is, with no close frame being sent). - wasClean: falselog @ pzpega_ui_messaging_1802554968!!.js:3265 pzpega_ui_messaging_1802554968!!.js:3265 Websocket failed on first connection attempt. Downgrading to long-polling and resending

You can disregard this message.

However, to take advantage of the improvements to real-time notifications, enable support for WebSocket:

  • For IBM WebSphere Application Server Liberty Core, see your deployment guide for instructions on configuring the application server.
  • For Red Hat JBoss, see your deployment guide for instructions on enabling WebSocket support.
  • For Apache Tomcat application servers, consider upgrading to Apache Tomcat 7.0.53 or later which supports WebSocket.

prpcUtils script fails when the connection property file location is specified

Valid from Pega Version 7.2.2

If you run the prpcUtils command-line script and pass the --connPropFile argument to specify the location of the connection properties file, the script fails with the following error:

Problem: failed to create task or type ac:/antcontrib.org:for

This error does not appear if you do not pass the --connPropFile argument, or if you use the prpcServiceUtils scripts.

As a workaround, edit the prpcUtilsWrapper.xml file:

  1. Open <distribution>\scripts\utils\prpcUtilsWrapper.xml.
  2. Locate the following line:

    <taskdef resource="net/sf/antcontrib/antcontrib.properties" uri="ac:/antcontrib.org">

  3. Replace that line with the following line.

    <taskdef resource="net/sf/antcontrib/antlib.xml" uri="ac:/antcontrib.org">

  4. Save and close the file.

Data schema requires update after multitenant upgrade

Valid from Pega Version 7.2.2

After an out-of-place, multitenant upgrade to Pega 7.2.2 from Pega 7.2 or later, the PR_DATA_TAG_RELEVANTRECORD table that is in the existing data schema is not present in the new rules schema. The table must be present in the rules schema for the upgrade to the rules schema to work. Copy the PR_DATA_TAG_RELEVANTRECORD table from the existing data schema to the new rules schema, and then upgrade the new rules schema. The PR_DATA_TAG_RELEVANTRECORD table is not required to be in the rules schema. After the rules schema upgrade is finished, drop the copy of the table that is in the new rules schema before you upgrade the data schema.

Upgrade/update fails if PostGIS is applied to PegaRULES or PegaDATA schema

Valid from Pega Version 7.2.1

If you use the PostGIS extension to a PostgreSQL database, upgrading or updating the Pega 7 Platform fails if the extension has been applied to either the PegaRULES or PegaDATA schema. PostGIS can be applied to any other schema.

Primary key constraint error when using JBoss

Valid from Pega Version 7.1.9

A primary key constraint violation exception might occur in the following situation: you use JBoss EAP 6.4 and SQL Server 2012 with a JDBC 4 driver, and you use two or more file listeners or JMS MDB listeners with concurrent threads that create work objects that use multiple files. If a primary key constraint violation exception occurs in this situation, update the data source configuration file to set the jta parameter to true. For example, set <datasource jta="true" jndi-name-"java:/jdbc/PegaRULES>.

Push notifications and Oracle WebLogic Server 10.3.6

Valid from Pega Version 7.2.2

Pega® Platform push notifications can use WebSockets and long polling. However, for WebLogic Server 10.3.6, the push notifications feature does not work. To disable the feature, contact Pegasystems Global Customer Support.

Load balancing: HTTPD does not support WebSockets by default

Valid from Pega Version 7.2.2

If you use a load balancer with HTTPD (Hypertext Transfer Protocol Daemon), HTTPD does not support fully functional WebSockets and sticky sessions. By default, HTTPD does not support sticky sessions, because if it did, after a session was started, the same server would serve all requests for that session.

WebSphere log error with Java 8 for Enterprise JavaBeans

Valid from Pega Version 7.1.8

For environments that are deployed by using Java 8 on IBM WebSphere Application Server version 8.5.5.9 through the last 8.5.5.x fix pack, the log might report that a class was not found when the application server attempts to start Enterprise JavaBeans. If Java EE functionality is not needed, no further action is required. However, to use Enterprise JavaBeans, see WebSphere log error with Java 8 for Enterprise JavaBeans.

Upgrades and updates from Pega 7.3 on MSSQL fail with column name mismatch

Valid from Pega Version 7.3

This failure applies only to upgrades and updates from Pega® Platform 7.3 on systems running Microsoft® SQL Server®. In Pega 7.3, the capitalization for the column name pc_work_agile.pzPvStream is incorrect. The correct capitalization is pzPVStream. To prevent upgrade and update failures, before you upgrade or update, run the following command from the Microsoft SQL Server Management Studio (SSMS) to rename the column:

EXEC sp_rename ‘data-schema-name.pc_work_agile.pzPvStream', 'pzPVStream', 'COLUMN'

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice