Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

No longer supported translator configuration options

Valid from Pega Version 7.4

The following translator configuration options are not needed and are no longer supported. If you previously configured any of these system settings, remove them from the system settings to avoid a warning message. For example, if you set translator/useparserfamily, the following message is displayed at startup: "Translator option, 'translator/useparserfamily' is not needed and no longer supported. Remove this from the system settings."

  • translator/useparserfamily
  • translator/usecodegenerator
  • translator/usenativedouble
  • translator/optimization/use71BlockAnalysis
  • translator/optimization/use71ConstantFolding
  • translator/optimization/use71AssignmentTypeSimplification
  • translator/optimization/use71IntrinsicFunctions
  • translator/use71PropSetGeneration
  • translator/use71ParserAssignment
  • assembly/model/useBlock4ContiguousSets
  • /translator/pandc/comparepandcalgorithms
  • /translator/pandc/use6xalgorithms
  • /Compatibility/CheckForTopLevelClassMismatch

In addition, the com.pega.pegarules.generation.parseoverride bootstrap option is no longer supported. Remove this option from the system settings.

PegaDATA connection settings now required in the prconfig.xml file

Valid from Pega Version 7.4

If you use the default prconfig.xml file that is included with Pega® Platform, and you have not removed the PegaDATA connection settings, no action is required. If you use a custom prconfig.xml file, for example, for running tests, ensure that the database connection settings for PegaDATA are not blank.

For more information about the connection settings, see PegaDATA connection settings in the prconfig.xml file.

Naming pattern changed for file data sets

Valid from Pega Version 8.6.3

File data sets are used to import from and export data to a file repository. In case of data export, prior to version 8.6.3, the first file exported had the same file name that was provided by the user in the data set, and any subsequent file exported to the repository had a unique identifier appended to it. Starting in Pega Platform version 8.6.3, each file has a unique identifier, automatically generated based on the data flow node, thread ID, and timestamp.

Upgrade impact

If your process to consume output files expects files with a specific name, it may not be able to process the resulting files correctly.

What steps are required to update the application to be compatible with this change?

If you have configured the process before updating to Pega Platform version 8.6.3, but the exported files are no longer recognized by downstream processing logic after the upgrade, ensure that the downstream tool is configured to recognize the files by a pattern rather than the full name. For example, when referring to files exported to the repository, use the * character to indicate a pattern instead of using the full file name. For example, use Export*.csv to refer to the files.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us