Tomcat log files moved to work directory

Valid from Pega Version 7.1.2

For Tomcat application server users, the default path for PRPC logs has been changed to the "work" directory for Catalina. For example:

<tomcat>\work\Catalina\localhost\prweb

This directory can be cleaned up during administration. To avoid loss of files, you can redirect logging to a different directory after installation:

  1. Navigate to the <tomcat-home>\webapps\prweb\WEB-INF\classes directory.
  2. Open the prlogging.xml file.
  3. Locate the "appender" definitions section that contains the "@{web.tmpdir}" string
  4. Update the FileNamePattern values to point to the new directory.

For more details, refer to the “Change the default path to PRPC logs” section in the Tomcat installation guide for your database.

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Slow WebSphere performance on Mac platforms

Valid from Pega Version 7.1.2

Use the following JVM setting to improve WebSphere performance on Mac platforms:

-Djava.net.preferIPv4Stack=true

Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

Decision Strategy Manager

Valid from Pega Version 7.1.3

Fixes were made that improve the configuration and execution of Batch Decisions. In particular,  the capability to use Structured Data has been enhanced. Some notable improvements have also been made to the UI of Visual Business Director.

  • The structured data input configuration will now work even though there is no data.
  • VBD has been enhanced to work with Version 7.1.
  • The structured data input configuration will now work with nested structures.
  • Association rules from Version 6.3 will now work with 7.1 structured data.

System Management

Valid from Pega Version 7.1.3

The PRPC installer has been enhanced to handle additional error conditions related to partial installs and duplicate keys; additionally, the hotfix rollback feature has been improved, and the Rulebase compare tool now supports HTTP(S) environments.

  • Rollback feature has been enhanced.
  • RuleBase Compare will work for secure (HTTPS) environments as well as  non-secure (HTTP) environments.
  • Install will gracefully handle the presence of a duplicate key during import.
  • When install fails, system will set tables back to original state.
  • Remote MBean methods will now work on multi-servant load-balancing systems.
  • Enhancements were made to harnesses in Split Schema systems.

Data schema error on z/OS split schema upgrades from versions before Pega 7.1.8

Valid from Pega Version 4.1

When upgrading to a split schema on Pega 7.x with IBM DB2 for z/OS, you see an error during the data schema upgrade when the system tries to drop the PRPC_Updatescache procedure. Because triggers on rules tables use PRPC_Updatescache, you must use the ZOSDisableTriggerScripts to disable these triggers before you update the data schema.

  1. Follow the instructions in the Pega 7 Platform Upgrade Guide to upgrade the rules schema, but stop immediately before you upgrade the data schema with the upgrade.bat or upgrade.sh script. The Pega 7 Platform Upgrade Guide is on the Support > Deployment Guides page.
  2. Copy the contents of the <distribution>\ResourceKit\ZOSDisableTriggerScripts directory into the <distribution>\scripts\ directory.
  3. Run fixZosTriggers.bat or fixZosTriggers.sh with the following arguments:
    --action preupgrade
    --dataschema <data schema name>
    --oldrulesschema <old rules schema name. If you are upgrading from a single-schema system, this is the data schema name.>
    --newrulesschema <new rules schema name>
    --automaticddl <Optional. Set to true to automatically apply the disable trigger SQL scripts.>

    For example:
    fixZosTriggers --action preupgrade --dataschema pegadata --oldrulesschema pegarules --newrulesschema newrules --automaticddl false

  4. If you did not set --automaticddl to true in the previous step, run the <distribution>\schema/disable.sql script to manually disable the trigger SQL scripts.
  5. Run the data schema upgrade as described in the Pega 7 Platform Upgrade Guide.

Support for predictive models in PMML version 4.4

Valid from Pega Version 8.5

Pega Platform™ now supports the import of predictive models in Predictive Model Markup Language (PMML) version 4.4. With this feature, you can import PMML models that use the anomaly detection algorithm.

For a list of all supported PMML models, see Supported models for import

 