Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Tomcat log files moved to work directory

Valid from Pega Version 7.1.2

For Tomcat application server users, the default path for PRPC logs has been changed to the "work" directory for Catalina. For example:

<tomcat>\work\Catalina\localhost\prweb

This directory can be cleaned up during administration. To avoid loss of files, you can redirect logging to a different directory after installation:

  1. Navigate to the <tomcat-home>\webapps\prweb\WEB-INF\classes directory.
  2. Open the prlogging.xml file.
  3. Locate the "appender" definitions section that contains the "@{web.tmpdir}" string
  4. Update the FileNamePattern values to point to the new directory.

For more details, refer to the “Change the default path to PRPC logs” section in the Tomcat installation guide for your database.

Slow WebSphere performance on Mac platforms

Valid from Pega Version 7.1.2

Use the following JVM setting to improve WebSphere performance on Mac platforms:

-Djava.net.preferIPv4Stack=true

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

Generate documents in the background

Valid from Pega Version 7.1.8

When you generate system documentation by using the Document Application wizard (Designer Studio > Application > Tools > Document), the process now runs on a server and not on your local client system. This change not only generates your document more quickly, but also allows you to multi-task within Pega 7 while your document is generating in the background. When the generation is completed, download the document to your computer.

For more information, see:

Updating customized Application Document templates with server-side document generation

Screenshot generation still runs on local client

Warning message when opening server-generated documents

Screenshot generation runs on local client

Valid from Pega Version 7.1.8

If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.

Warning message when opening server-generated documents

Valid from Pega Version 7.1.8

Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.

If you click No, certain content (for example, Table of Contents) is not populated in the document. Instead, click Yes and save the document.

Warning message dialog

The warning message that displays

Link URLs to applications, requirements, and specifications

Valid from Pega Version 7.1.8

In addition to files, you can now attach URLs to applications, requirements, and specifications by using the Add/Edit Attachment modal dialog box in Pega 7. This change allows you to link directly to dynamic content in other URL-based systems rather than link to a static file of that content.

Custom database (DB) triggers are dropped during upgrade

Valid from Pega Version 7.1.8

The latest version of Pega 7 improves performance by no longer using database triggers to assist with System Pulse and Data-Rule-Summary processing, which is now done within the Pega 7 engine. As a result, DB triggers are no longer installed on either the pr_sys_updatescache or pr4_rule_vw tables.

When upgrading to the latest version of Pega 7, if you had previously implemented a custom database (DB) trigger on these tables, or a custom DB trigger that refers to these tables, it is removed during the upgrade process. No custom triggers are removed unless they reference these tables.

If you have custom DB triggers that reference the pr_sys_updatescache or pr4_rule_vw tables and perform other processing, those triggers must be reimplemented. When doing so, you must be careful to not modify the pr_sys_updatescache or pr4_rule_vw tables.

For more information, see Startup check removes custom DB triggers.

Identify, install, and manage hotfixes with the Hotfix Manager

Valid from Pega Version 7.1.8

Hotfixes are packages of files that address issues in Pega 7 and in participating Industry Applications. With Hotfix Manager, you can:

  • Scan your system for installed and missing critical hotfixes and create a report that you can provide to Pegasystems Support for diagnostic purposes.
  • Review the descriptions and contents of hotfixes.
  • Install, rollback, and commit hotfixes.
  • Manage hotfixes that include schema changes or require other special handling.

The Hotfix Manager replaces the Update Manager Hotfix Installer and System Scanner, both of which are deprecated. For more information, see Hotfix Manager identifies, installs, and manages hotfixes to Pega 7 and participating Industry Applications.

Enhanced product rule form for easy application packaging

Valid from Pega Version 7.1.8

The enhanced product rule form allows you to add applications in Delta mode, which includes only the patch version of the rulesets that comprise the application rule. You can also use Global exclusions to exclude one or more rules that are not associated with a ruleset version.

These enhancements allow easy packaging of non-versioned rules that are often deployed separately and reduce the need to manually add them later.

For more information, see Product rules - Completing the Contents tab.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us