No longer supported translator configuration options

Valid from Pega Version 7.4

The following translator configuration options are not needed and are no longer supported. If you previously configured any of these system settings, remove them from the system settings to avoid a warning message. For example, if you set translator/useparserfamily, the following message is displayed at startup: "Translator option, 'translator/useparserfamily' is not needed and no longer supported. Remove this from the system settings."

  • translator/useparserfamily
  • translator/usecodegenerator
  • translator/usenativedouble
  • translator/optimization/use71BlockAnalysis
  • translator/optimization/use71ConstantFolding
  • translator/optimization/use71AssignmentTypeSimplification
  • translator/optimization/use71IntrinsicFunctions
  • translator/use71PropSetGeneration
  • translator/use71ParserAssignment
  • assembly/model/useBlock4ContiguousSets
  • /translator/pandc/comparepandcalgorithms
  • /translator/pandc/use6xalgorithms
  • /Compatibility/CheckForTopLevelClassMismatch

In addition, the com.pega.pegarules.generation.parseoverride bootstrap option is no longer supported. Remove this option from the system settings.

PegaDATA connection settings now required in the prconfig.xml file

Valid from Pega Version 7.4

If you use the default prconfig.xml file that is included with Pega® Platform, and you have not removed the PegaDATA connection settings, no action is required. If you use a custom prconfig.xml file, for example, for running tests, ensure that the database connection settings for PegaDATA are not blank.

For more information about the connection settings, see PegaDATA connection settings in the prconfig.xml file.

Changes in JSON results when checking the health of your system

Valid from Pega Version 8.2

Beginning with Pega Platform™ 8.2, the JSON results that are returned when you ping a Pega Platform instance have changed. JSON results now include node type and health information, including test name, status, state, and node ID. The following samples show JSON results from versions before 8.2 and as of 8.2.

JSON results for pre-Pega Platform 8.2:

{ "duration":"3954.448601", "count":"0" }

JSON results for Pega Platform 8.2 and later:

{"node_type":["WebUser"],"health":[{"last_reported_time":"2019-02-14T16:10:49.589Z","test_name":"Sample-Stream-Check","status":"success"}],"state":"healthy","node_id":"10.10.10_samplenode"}.