Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Supported JDBC drivers

Valid from Pega Version 7.1.1

Pega 7.1.1 supports Java 6 and Java 7 SDKs only. Ensure that the JDBC driver you are using supports those versions of Java. See your database installation or upgrade documentation for additional information.

DatabaseJava 6Java 7
Oracleojdbc6.jarojdbc7.jar
MSQLsqljdbc4.jarsqljdbc4.jar
DB2 LUWdb2jcc4.jardb2jcc4.jar
DB2 z/OS*db2jcc4.jar or jdb2jcc.jar**db2jcc4.jar
PostgreSQLpostgresql-9.1-903.jdbc4.jar***postgresql-9.1-903.jdbc4.jar

* JDBC drivers are only available from the DB2 for z/OS product. Additionally, you need db2jcc_license_cisuz.jar in the same directory as db2jcc4.jar.

** The db2jcc.jar has been deprecated and may not be supported in future releases.

*** This .jar file is required for PostgreSQL version 9.1.x.

Turn off saved connections in WebLogic

Valid from Pega Version 7.1.1

PRPC caches connections in thread-local storage. When using a WebLogic application server, set database/savedconnections to FALSE to avoid incorrectly saved, container-managed transactions. You can make this update through JNDI settings or by adding an entry to the prconfig.xml, for example:

<env name="database/savedconnections" value="false" />

Automated Unit Testing is unavailable

Valid from Pega Version 7.1.1

Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.

Starting in 7.1.6, users can access AUT features from supported browser versions of IE.

Deprecated end user portals

Valid from Pega Version 7.1.1

The following portals are no longer be supported:

  • SysAdmDD
  • WorkUserDD
  • WorkManagerDD

As a best practice, customize standard, supported portals rather than update your existing portals to include new features.

IE8 hangs on large imports

Valid from Pega Version 7.1.1

IE8 users may experience a hung process when running the Designer Studio > Application > Distribution > Import wizard. This issue is related to low-capacity networks and large (300+ MB) archive files.

Although the processing symbol prevents you from proceeding to the next step in the wizard, the file is still imported to the server. As a workaround, you can:

  1. Wait approximately eight minutes for the file to import.
  2. Close and restart the wizard.
  3. Click Next to skip the upload step.
  4. Select the name of your file from the list of import files.
  5. Complete the remaining steps in the wizard.

Required DB2 settings

Valid from Pega Version 7.1.1

For customers using the DB2 Version 4 drivers (“db2jcc4.jar”), it is necessary to set the custom connection property useJDBC4ColumnNameAndLabelSemantics to “false”.   

For customers using DB2 with WebSphere, the useJDBC4ColumnNameAndLabelSemantics property in the DB2 data source needs to be changed from a Boolean to an Integer and set to "2". 

IE8 limits expansion features

Valid from Pega Version 7.1.1

Internet Explorer 8 (IE8) does not support CSS media queries, which are used by re-expansion features in the Designer Studio. IE8 users with low screen resolution (800 x 600) and a small window size may find that the explorer area in the Designer Studio collapses but cannot re-expand. 

As a work around, access the Designer Studio from another supported browser version and use the recommended, minimum screen resolution width of 1280 pixels.

Application Express and the Content Security Policy

Valid from Pega Version 7.1.7

Application Express copies (if defined) the Content Security Policy (CSP) name (pyContentSecurityPolicyName) from the built-on application in a new application. It also sets the CSP mode (pyContentSecurityPolicyMode) to report. The values appear in the Content Security area on the application rule's Integration & Security tab.

When checking an application in the DCO Compatibility tool, a warning appears if the CSP name is missing.

Limited access for end user portals

Valid from Pega Version 7.1.1

The following portals are only accessible from supported versions of Internet Explorer in “quirks” mode:

  • WorkUser
  • WorkManager

Nesting dynamic containers not supported

Valid from Pega Version 7.1.1

Do not include a section containing a dynamic container inside of another dynamic container. This configuration may cause performance issues resulting in unexpected behavior at runtime, and is not supported.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us