DB2-LUW database logfile size increase

Valid from Pega Version 7.1.5

This issue applies to DB2-LUW database platforms only.
 

To avoid running out of logfile space due to large transaction sets during the rule base load of a Pega 7.1.x install, upgrade, or maintenance level update, systems supported by a DB2-LUW database platform should increase the LOGFILSIZ parameter to at least 4096 pages from the default size of 1000 pages.

After the size has been increased, restart the database to ensure that the new setting is loaded into the database correctly.

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

Existing operator IDs during upgrades and updates

Valid from Pega Version 7.2.2

Upgrades and updates are always performed in secured mode to help prevent unauthorized access to your system. In secured mode, the [email protected] operator ID is always overwritten, but other existing standard operator IDs are not modified. New operator IDs are inserted in secured mode. For more information, see the Deployment Guide for your environment.

BIX -I command-line option fails for unexposed properties

Valid from Pega Version 7.2.2

Business Intelligence Exchange (BIX) command-line extractions fail when the extract has a filter that uses unexposed property references that are passed in by the input file that you specified in the -I command-line option. Previously, the BIX extraction ignored the filter and the extraction did not fail.

Upgrade utility for Get Next Work performance

Valid from Pega Version 7.2.2

You can run a utility to upgrade Get Next Work processing to more quickly process assignments that were created in versions of the Pega 7 Platform earlier than 7.2.2. Performance is automatically improved on new installations.

For more information, see Upgrading Get Next Work performance.

Pega File Listener process changes

Valid from Pega Version 7.2.2

Beginning with Pega 7.2.2, File Listener processes files in a different way:

  • File movement in directories – Previously, files were processed from the Work directory. In Pega 7.2.2, files are processed from the source location. Files move to the Work directory only if the initial processing fails and Recovery is disabled.
  • New file processing – Previously, File Listener would process all files in the source location, even if the files were added during the processing. In Pega 7.2.2, files added to the source location during processing are read the next time the File Listener starts.

For more information, see File Listener data instances.

Remove obsolete versions of the PredictiveAnalytics-UI and PredictiveAnalaytics-IntSvcs rulesets

Valid from Pega Version 7.2.2

After you upgrade the Pega 7 Platform to version 7.2.2, remove the PredictiveAnalytics-UI and PredictiveAnalytics-IntSvcs rulesets from your application as their versions are obsolete. Beginning with Pega 7.2.2, use the Pega-DecisionScience ruleset that contains the latest versions of the PredictiveAnalytics-UI and PredictiveAnalytics-IntSvcs rulesets.

For more information, see About ruleset versions.

Automated Unit Testing (AUT) content removed from the help

Valid from Pega Version 7.2.2

Information about Automated Unit Testing (AUT) has been removed from the Pega 7 Platform help, beginning with version 7.2.2. The AUT information is still available in earlier versions of the Pega 7 Platform help and on the PDN in the topic category Testing Applications.

PegaUnit testing is now supported on data pages, activities, data transforms, strategies, decision tables, and decision trees, which you can use to quickly and easily create test cases for your Pega 7 Platform applications instead of using AUT.

For more information, see:

Issue with the Sandbox directive on the Content Security Policy rule form has been fixed

Valid from Pega Version 7.2.2

An issue that related to the Sandbox directive not being applied, even after a value in the Content Security Policy rule form was selected, has been fixed. As a result, restrictions that are applied based on the settings in the Sandbox directive are now more closely aligned with the World Wide Web Consortium (W3C) specification than in previous releases. You should test your Content Security Policy to ensure that this change does not cause unexpected behavior in your application, such as making the security policy too restrictive.

Reconfiguration of the Adaptive Decision Manager service after upgrade to Pega 7.2.2

Valid from Pega Version 7.2.2

After you upgrade the Pega 7 Platform to version 7.2.2 from a version prior to 7.2,1, you need to configure the Adaptive Decision Manager service. Beginning with Pega 7.2.1, the Adaptive Decision Management (ADM) service is native to the Pega 7 Platform and is supported by the Decision data node infrastructure.

For more information, see Services landing page.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us