Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Existing operator IDs during upgrades and updates

Valid from Pega Version 7.2.2

Upgrades and updates are always performed in secured mode to help prevent unauthorized access to your system. In secured mode, the [email protected] operator ID is always overwritten, but other existing standard operator IDs are not modified. New operator IDs are inserted in secured mode. For more information, see the Deployment Guide for your environment.

System starts slowly after upgrade or update on IBM DB2 for z/OS

Valid from Pega Version 7.2.2

Additional tables are added to upgraded and updated systems. If your system starts up very slowly after an upgrade or update, the database statistics on these new tables might not have generated correctly. To correct this issue and improve performance, your database administrator needs to manually rebuild the statistics for all tables in the rules schema.

BIX -I command-line option fails for unexposed properties

Valid from Pega Version 7.2.2

Business Intelligence Exchange (BIX) command-line extractions fail when the extract has a filter that uses unexposed property references that are passed in by the input file that you specified in the -I command-line option. Previously, the BIX extraction ignored the filter and the extraction did not fail.

Upgrade utility for Get Next Work performance

Valid from Pega Version 7.2.2

You can run a utility to upgrade Get Next Work processing to more quickly process assignments that were created in versions of the Pega 7 Platform earlier than 7.2.2. Performance is automatically improved on new installations.

For more information, see Upgrading Get Next Work performance.

Clustering equal to none might cause errors

Valid from Pega Version 7.2.2

Some Pega 7 Platform features might not work when theidentification/cluster/protocolsetting in the prconfig.xml file is set to none. Some features that might not work are remote tracing and management actions on the node from the Requestor Management and Agent Management landing pages. Setting the clustering protocol to none is not recommended and will not be supported in a future Pega 7 Platform release.

Pega File Listener process changes

Valid from Pega Version 7.2.2

Beginning with Pega 7.2.2, File Listener processes files in a different way:

  • File movement in directories – Previously, files were processed from the Work directory. In Pega 7.2.2, files are processed from the source location. Files move to the Work directory only if the initial processing fails and Recovery is disabled.
  • New file processing – Previously, File Listener would process all files in the source location, even if the files were added during the processing. In Pega 7.2.2, files added to the source location during processing are read the next time the File Listener starts.

For more information, see File Listener data instances.

Remove obsolete versions of the PredictiveAnalytics-UI and PredictiveAnalaytics-IntSvcs rulesets

Valid from Pega Version 7.2.2

After you upgrade the Pega 7 Platform to version 7.2.2, remove the PredictiveAnalytics-UI and PredictiveAnalytics-IntSvcs rulesets from your application as their versions are obsolete. Beginning with Pega 7.2.2, use the Pega-DecisionScience ruleset that contains the latest versions of the PredictiveAnalytics-UI and PredictiveAnalytics-IntSvcs rulesets.

For more information, see About ruleset versions.

Reconfiguration of the Adaptive Decision Manager service after upgrade to Pega 7.2.2

Valid from Pega Version 7.2.2

After you upgrade the Pega 7 Platform to version 7.2.2 from a version prior to 7.2,1, you need to configure the Adaptive Decision Manager service. Beginning with Pega 7.2.1, the Adaptive Decision Management (ADM) service is native to the Pega 7 Platform and is supported by the Decision data node infrastructure.

For more information, see Services landing page.

Disregard this startup error for Oracle Weblogic deployments

Valid from Pega Version 7.2.2

If you install, upgrade, or update your Oracle Weblogic application server to Pega 7.2.2, disregard the error stack that begins with text similar to the following:

ERROR - WebLogic Server 12.1.3.0.0 Wed May 21 18:53:34 PDT 2014 1604337 Oracle WebLogic Server Module Dependencies 12.1 Tue Mar 11 15:35:15 MDT 2014 WebLogic Jersey Server Integration 3.0 Fri Feb 21 10:55:11 UTC 2014 must use JDK 1.8+ with WebSocket
2016-11-07 06:13:01,690 [ WIN-L3EEURCNCP1] [ STANDARD] (pr.DefaultAsyncSupportResolver) ERROR - Real error: Unable to configure jsr356 at that stage. ServerContainer is null

This message appears because the Pega 7.2.2 real-time notification feature initially tries to use WebSocket and then falls back to long polling. The Pega 7 Platform does not support WebSocket for Oracle Weblogic servers, and instead uses long polling for real-time notifications.

Functionality of the pyInvokeRESTConnector rule and the pxDeferenceEndpoint rule moved to core engine

Valid from Pega Version 7.2.2

The functionality of the pyInvokeRESTConnector rule and the pxDeferenceEndpoint rule has been moved into the core engine code of the Pega 7 Platform. This change provides more consistent behavior, reduces maintenance, and reduces the risk of regression issues. As a result, you can no longer customize these rules, and upgrading the Pega 7 Platform requires special considerations if you previously customized these rules.

For more information, see Upgrading with customized pyInvokeRESTConnector and pxDeferenceEndpoint rules.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us