DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Stages and Steps may not appear as expected

Valid from Pega Version 7.1.5

There are some unique configurations of the newly enhanced pxDisplayStages gadget that can lead to case type "Stages and Steps" appearing more than once or not at all.  In the event that your application experiences one of these scenarios, the recommended work around is to relocate the gadget:

  • Add pxDisplayStages to the pyCaseContainer section (or equivalent)
  • Remove pxDisplayStages from the pyCaseActionArea section (or equivalent).

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Column Populator utility documentation out of date for prior versions

Valid from Pega Version 7.2

The documentation for using the Column Populator utility to populate newly exposed database columns is out of date for Pega 7 Platform versions prior to 7.2. For all Pega 7 versions, refer to the Pega 7.2 help documentation for instructions about how to use this utility.

Cannot view all custom context posts in Pulse

Valid from Pega Version 7.2

When you use Pulse in a custom context, the custom context label is displayed as plain text instead of as a link that you can click to view all posts that are associated with the custom context.

For more information about Pulse, see the help topic Pulse.

Child case queries performance can be slow

Valid from Pega Version 7.2

Some customers have reported that performance is slow when they execute queries on child cases. This issue is often indicated by PEGA0005 (query time exceeded limit) alerts that can be correlated to these queries in the logs. To resolve the issue, add a database index to each of your work tables by using a multicolumn index on the pxCoverInsKey, pxObjClass, and pyStatusWork columns.

See Performance improvements for child case queries.

Verify ML Readiness error: Upgrades from Pega 7.1.0 through 7.1.8 do not replace nonversioned rules

Valid from Pega Version 7.2

Upgrading from any Pega 7 Platform version between Pega 7.1 and Pega 7.1.8 to Pega 7.2 does not automatically replace nonversioned rules. If you revalidated and saved a Pega 7.1.x rule after the timestamp on the Pega 7.2 version of the rule, upgrading to Pega 7.2 does not overwrite the saved rule. You might see either of the following behaviors:

  • The upgrade fails with the following error message:
    Verify ML Readiness
  • The upgrade succeeds, but you might be unable to open changed rule forms.

If the upgrade fails, see the Pega 7 Platform Upgrade Guide to force the upgrade.

This known issue does not affect Pega 7.1.9. After the upgrade has finished, apply Hotfix 27288. For information about obtaining and applying hotfixes, see Hotfix Manager.