Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Context-specific documentation is not available in express mode

Valid from Pega Version 7.1.9

Help topics that are opened from express mode display content that is specific to Designer Studio.

If your system is dedicated to applications that are developed in express mode exclusively, and you do not need Designer Studio help topics, you can set the Online Help URL field on the System Settings landing page to: https://pdn.pega.com/sites/default/files/help_p7e/procomhelpmain.htm. Alternatively, you can view the contextual help system for Pega 7 Express in a separate browser tab.

Design-time limitations in express mode

Valid from Pega Version 7.1.9

Some limitations apply when you develop an enterprise application in express mode. At design time, some features are disabled or have limited options when you configure them in Designer Studio and switch to express mode. The use of these features does not restrict the run-time behavior of your application; however, you cannot change the configuration of these features unless you switch from express mode to Designer Studio.

For more information about each limitation and the recommended action to take, see the following information:

Problem with truncating Decision Data Store data set

Valid from Pega Version 7.1.9

The Truncate operation for the Decision Data Store data set may cause timeout exceptions. This problem is caused by the Apache Cassandra database that waits until compaction tasks finish before it can truncate the data set.

Recommendation:

Repeat the Truncate operation until it is successful.

Primary key constraint error when using JBoss

Valid from Pega Version 7.1.9

A primary key constraint violation exception might occur in the following situation: you use JBoss EAP 6.4 and SQL Server 2012 with a JDBC 4 driver, and you use two or more file listeners or JMS MDB listeners with concurrent threads that create work objects that use multiple files. If a primary key constraint violation exception occurs in this situation, update the data source configuration file to set the jta parameter to true. For example, set <datasource jta="true" jndi-name-"java:/jdbc/PegaRULES>.

Rule revalidation after updating properties without restarting nodes

Valid from Pega Version 8.2

When you update certain property attributes, such as a property's maximum length, rule types that reference the property might not reflect the change. You do not always have to restart nodes to revalidate the referencing rules when they cannot be resaved, for example, when they are in a locked ruleset. For Pega Platform™ 8.1 and later, for non-stream rules, such as activities, data transforms, and so on, use the reassemble API in Admin Studio or truncate the assembled classes table.

For stream rules, such as sections, harnesses, paragraphs, and so on, reassemble the rules and restart the nodes. For more information, see More about properties.

For previous versions of Pega Platform, use the System Management Application (SMA) to revalidate stream and non-stream rules.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us