Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Stages and Steps may not appear as expected

Valid from Pega Version 7.1.5

There are some unique configurations of the newly enhanced pxDisplayStages gadget that can lead to case type "Stages and Steps" appearing more than once or not at all.  In the event that your application experiences one of these scenarios, the recommended work around is to relocate the gadget:

  • Add pxDisplayStages to the pyCaseContainer section (or equivalent)
  • Remove pxDisplayStages from the pyCaseActionArea section (or equivalent).

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Screenshot generation runs on local client

Valid from Pega Version 7.1.8

If you generate screenshots to include in your application document, this process still runs on your local client. Additionally, you are still required to use Internet Explorer to use this feature.

Warning message when opening server-generated documents

Valid from Pega Version 7.1.8

Depending on your system configuration, the following warning message might be displayed when you open a document that was generated on the server.

If you click No, certain content (for example, Table of Contents) is not populated in the document. Instead, click Yes and save the document.

Warning message dialog

The warning message that displays

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

The Create Build button appears grayed out when configuring and building a mobile application

Valid from Pega Version 7.1.8

When you attempt to configure and build your Android or iOS mobile application from the Mobile tab, the Create build button might appear dimmed. This issue occurs if any of the access roles in the access group were cloned from the PegaRULES:SysAdm4 access role.

Refer to Troubleshooting Pega Mobile Client to learn how to fix this issue in your application.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us