Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Updated Word merge support with Microsoft Silverlight plug-in

Valid from Pega Version 7.1.3

Starting in this release, Pega 7 features that integrate with the Word merge capability are now cross-browser. ActiveX controls (which are only compatible with Internet Explorer) have been replaced with Microsoft Silverlight. This plug-in must be downloaded separately from Microsoft because it is not shipped with Pega 7.

Common features that are affected by this change include the Specification form and Case Type landing page.

Prior to using these features, see the release note Word merge support with Microsoft Silverlight plug-in for more information about setting up their client systems.

End of support for Microsoft Internet Explorer 9 in Pega 7.2.1

Valid from Pega Version 7.2.1

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9, Pega 7.2.1 will not support Internet Explorer 9. You should not upgrade to Pega 7.2.1 if you are still using Internet Explorer 9. Otherwise, upgrade to Microsoft Internet Explorer 10 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox, which support certain HTML5 and CSS3 standards not supported in Internet Explorer 9.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

 

 

 

Discontinued support for multithreaded requestors

Valid from Pega Version 7.2.1

Multithreaded requestors are no longer supported in the Pega 7 Platform. Multithreading was previously specified by the prconfig setting initialization/allowMultiplePRThreads. If this setting is set to true when you upgrade to Pega 7.2.1, errors occur during the quiesce process.

Child case queries can be slow after upgrade

Valid from Pega Version 7.2.1

After upgrading, performance might be slow when you run queries on child cases for work tables that existed prior to the upgrade. This issue is often indicated by PEGA0005 (query time exceeded limit) alerts that can be correlated to these queries in the logs. To resolve the issue, add a database index to each of your work tables by using a multicolumn index on the pxCoverInsKey, pxObjClass, and pyStatusWork columns.

For more information, see Performance improvements for child case queries.

The UpdateAdaptiveModels agent causes an exception after Pega 7.2 to 7.2.1 upgrade

Valid from Pega Version 7.2.1

After the Pega 7 Platform is upgraded from version 7.2 to 7.2.1, the log files might show an error that is caused by the UpdateAdaptiveModels agent. This agent is enabled by default and is responsible for updating scoring models in the Pega 7 Platform. If you use adaptive models in your solution, you can avoid this error by configuring the Adaptive Decision Manager service. If you do not use adaptive models, disable the UpdateAdaptiveModels agent.

For more information, see Configuring the Adaptive Decision Manager service and Pega-DecisionEngine agents.

Reconfiguration of the Adaptive Decision Manager service after upgrade to Pega 7.2.1

Valid from Pega Version 7.2.1

After you upgrade the Pega 7 Platform to version 7.2.1, you need to reconfigure the Adaptive Decision Manager service. Beginning with Pega 7.2.1, the Adaptive Decision Management (ADM) service is native to the Pega 7 Platform and is supported by the Decision data node infrastructure.

For more information, see Services landing page.

Customizations to the prlogging.xml file must be manually ported after upgrade

Valid from Pega Version 7.3

As a result of the upgrade from the Apache Log4j 1 logging service to the Apache Log4j 2 logging service, the name of the logging configuration file has changed from prlogging.xml to prlog4j2.xml and the format of the file has changed considerably. If you customized your prlogging.xml file, port the customizations to the new prlog4j2.xml file. If you do not port the changes, the Pega® Platform uses the default prlog4j2.xml file and disregards your customized prlogging.xml file.

For more information about customizing your log files, see the Apache Log4j 2 documentation.

Socket server has changed for remote logging

Valid from Pega Version 7.3

As a result of the upgrade from the Apache Log4j 1 logging service to the Apache Log4j 2 logging service, the socket server that is used for remote logging has changed from the Log4j remote logging package with the LogFactor5 log analysis tool to TcpSocketServer. If you use remote logging, update your socket server to TcpSocketServer. For more information, see Installing and using remote logging.

New process for Pega Cloud customers to obtain BIX extract files

Valid from Pega Version 7.3

The process for obtaining Business Intelligence Exchange (BIX) extract and manifest files for Pega® Cloud customers has changed as a result of data security enhancements for HIPAA compliance. By default, after upgrading to Pega 7.3, you must obtain the BIX extract and manifest files from the Pega SFTP server. From within Designer Studio, you can configure the BIX extract and manifest files to be sent to a remote SFTP server by a file listener. For Pega Cloud customers who have purchased a Pega Cloud SFTP Server subscription, you can configure BIX to send the BIX extract and manifest files to the SFTP server's folders for remote SFTP client download.

For more information about obtaining files from the Pega SFTP server, see Obtaining BIX extract files from the Pega SFTP server.

For more information about having files sent to your SFTP server, see Defining SFTP-related data instances.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us