Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Updated Word merge support with Microsoft Silverlight plug-in

Valid from Pega Version 7.1.3

Starting in this release, Pega 7 features that integrate with the Word merge capability are now cross-browser. ActiveX controls (which are only compatible with Internet Explorer) have been replaced with Microsoft Silverlight. This plug-in must be downloaded separately from Microsoft because it is not shipped with Pega 7.

Common features that are affected by this change include the Specification form and Case Type landing page.

Prior to using these features, see the release note Word merge support with Microsoft Silverlight plug-in for more information about setting up their client systems.

End of support for Microsoft Internet Explorer 9 in Pega 7.2.1

Valid from Pega Version 7.2.1

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9, Pega 7.2.1 will not support Internet Explorer 9. You should not upgrade to Pega 7.2.1 if you are still using Internet Explorer 9. Otherwise, upgrade to Microsoft Internet Explorer 10 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox, which support certain HTML5 and CSS3 standards not supported in Internet Explorer 9.

For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

 

 

 

Discontinued support for multithreaded requestors

Valid from Pega Version 7.2.1

Multithreaded requestors are no longer supported in the Pega 7 Platform. Multithreading was previously specified by the prconfig setting initialization/allowMultiplePRThreads. If this setting is set to true when you upgrade to Pega 7.2.1, errors occur during the quiesce process.

Child case queries can be slow after upgrade

Valid from Pega Version 7.2.1

After upgrading, performance might be slow when you run queries on child cases for work tables that existed prior to the upgrade. This issue is often indicated by PEGA0005 (query time exceeded limit) alerts that can be correlated to these queries in the logs. To resolve the issue, add a database index to each of your work tables by using a multicolumn index on the pxCoverInsKey, pxObjClass, and pyStatusWork columns.

For more information, see Performance improvements for child case queries.

The UpdateAdaptiveModels agent causes an exception after Pega 7.2 to 7.2.1 upgrade

Valid from Pega Version 7.2.1

After the Pega 7 Platform is upgraded from version 7.2 to 7.2.1, the log files might show an error that is caused by the UpdateAdaptiveModels agent. This agent is enabled by default and is responsible for updating scoring models in the Pega 7 Platform. If you use adaptive models in your solution, you can avoid this error by configuring the Adaptive Decision Manager service. If you do not use adaptive models, disable the UpdateAdaptiveModels agent.

For more information, see Configuring the Adaptive Decision Manager service and Pega-DecisionEngine agents.

Reconfiguration of the Adaptive Decision Manager service after upgrade to Pega 7.2.1

Valid from Pega Version 7.2.1

After you upgrade the Pega 7 Platform to version 7.2.1, you need to reconfigure the Adaptive Decision Manager service. Beginning with Pega 7.2.1, the Adaptive Decision Management (ADM) service is native to the Pega 7 Platform and is supported by the Decision data node infrastructure.

For more information, see Services landing page.

Unit testing support for more rule types

Valid from Pega Version 8.3

You can now create unit tests for the following additional rule types. You can also create assertions to validate activity status. The expanded rule types for unit testing enable developers to more thoroughly perform regression testing of their application, thereby improving application quality.

  • Collection
  • Declare expression
  • Map value
  • Report definition

For more information about unit testing rules, see Pega unit test cases.

Upgrade impact

With the four new rule types, unit test execution and unit test compliance metrics will change. Reports on automated unit testing of the customer application decrease due to the increased pool of supported rules.

What steps are required to update the application to be compatible with this change?

After a successful upgrade, create Pega unit test cases for the newly supported rules to see updated and accurate unit test metrics.

Use Page-Change-Class method to change a Page class

Valid from Pega Version 8.3

With the release of Pega Platform™ 8.3, using the Property-Set method to change the Page class shows a guardrail warning. Use the Page-Change-Class method to change the Page class instead.

For more information about the Page-Change-Class method, see Changing the class of a page and Page-Change-Class method.

Cassandra 3.11.3 support for Pega Platform

Valid from Pega Version 8.3

Increase your system's reliability and reduce its memory footprint by upgrading the internal Cassandra database to version 3.11.3.

For on-premises Pega Platform™ users, after you upgrade to Pega 8.3, it is recommended that you manually upgrade to Cassandra 3.11.3. You can upgrade to Cassandra 3.11.3 on all operating systems except IBM AIX. If you do not want to upgrade to Cassandra 3.11.3, you can continue to use Cassandra 2.1.20, which is still supported.

For Pega Cloud Services 2.13 and later versions, Cassandra automatically upgrades to version 3.11.3 after your environment is upgraded to Pega Platform 8.3.

For information on how to manually upgrade to Cassandra 3.11.3, see the Pega Platform 8.3 Upgrade Guide for your server and database at Deploy Pega Platform.

Upgrade impact

After an on-premises Pega Platform upgrade, you still have the older version of Cassandra and must manually upgrade.

What steps are required to update the application to be compatible with this change?

To upgrade Cassandra, you must create a prconfig setting or a dynamic system setting with the new Cassandra version and then do a rolling restart of all the Decision Data Store nodes to upgrade them to the latest version of Cassandra.

 

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us