DB2-LUW database logfile size increase
Valid from Pega Version 7.1.5
To avoid running out of logfile space due to large transaction sets during the rule base load of a Pega 7.1.x install, upgrade, or maintenance level update, systems supported by a DB2-LUW database platform should increase the LOGFILSIZ parameter to at least 4096 pages from the default size of 1000 pages.
After the size has been increased, restart the database to ensure that the new setting is loaded into the database correctly.
Need to run script before updating Multitenant systems
Valid from Pega Version 7.1.5
When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:
“Table must be empty to add column.”
The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.
To avoid this error, before beginning the update or upgrade, it is necessary to run a script:
- Oracle —
OracleMTupgrade.sql
- PostgreSQL —
PostgresMTupgrade.sql
For updates, these scripts are located in the /scripts/ddl
directory.
For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts
directory.
Discontinued support for list view and summary view rules
Valid from Pega Version 7.2
The list view rule and the summary view rule are deprecated, and support for these rules has been discontinued. Existing list view and summary view reports will continue to work on supported browsers. However, the last version of Internet Explorer that list view and summary view rules support is Internet Explorer 11.
You cannot create new list view or summary view reports. Instead, create list reports and summarized reports by using the report definition rule. To prevent display issues, re-create the custom list view and summary view reports that you need as report definition reports.
Label changes to field types in Case Designer
Valid from Pega Version 7.2
The following field types have been renamed in Case Designer to be consistent with Data Designer and other areas of the Pega 7 Platform.
Label in previous versions | Label in Pega 7.2 |
---|---|
Text | Text (single line) |
Text (multiple lines) | Text (paragraph) |
Check box | Boolean |
Date and time | Date & time |
Date | Date only |
Drop down | Picklist |
Number (integer) | Integer |
Number (decimal) | Decimal |
Users who upgrade from versions prior to Pega 7.2 do not have to take any action because the label changes are cosmetic and do not affect the underlying controls or property types that support form building.
For more information about the field types that you can use when building a form, see Storage and display of single-value fields.
Process Outline view is unavailable
Valid from Pega Version 7.2
Process Outline view is no longer available as of this release. Use Case Designer instead to configure your processes. For advanced options, you can open the underlying flow for a process in Process Modeler.
For more information, see Designing a case type and Diagram tab on the Flow form.
New location for case-type settings
Valid from Pega Version 7.2
The configuration options for case-type settings have been moved from the property panel to the Settings tab in Case Designer. This change separates behavioral settings from life-cycle settings so that you can stay focused as you design your case types.
For more information, see Configuring case-type behavior.
No private posts in new Pulse gadget
Valid from Pega Version 7.2
The new Pulse gadget does not support private posts. When you upgrade to the new gadget, any private posts of the following types that you created by using the previous version of the gadget become public.
- Operator posts
- Case posts
- Posts that used the generic pxPostMessage API with private posts enabled
- Posts that used the Pulse smart shape in PRPC 6.3 or earlier with private posts enabled
For more information about the new Pulse gadgets for developers, Pulse gadgets and custom APIs.
For more information about the using the new Pulse gadget, see Communicating with Pulse.
Atom Server and SOAP Server rule forms are deprecated
Valid from Pega Version 7.2
The Atom Server and SOAP Server rule forms are deprecated. Use the Connect CMIS rule form instead.
Existing rules that were created with the deprecated forms still work, but you cannot create new ones.
End of support for Microsoft Internet Explorer 9 and Internet Explorer 10
Valid from Pega Version 7.2
In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 9 and Internet Explorer 10 in January 2016, Pega 7.2 will be the last version of the Pega 7 Platform to support Internet Explorer 9 and Internet Explorer 10.
For Pega 7.2.1, you must upgrade to Microsoft Internet Explorer 11 or later, or use Google Chrome, Apple Safari, or Mozilla Firefox.
For more information about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.
Processes run by default when a stage is restarted
Valid from Pega Version 7.2
The Run on re-entry check box in Case Designer has been removed. As a result of this change, processes run by default each time that a stage is restarted. Users who previously had this check box cleared can use the Start when option in Case Designer instead to define the criteria for skipping a process.
For more information, see Adding a process to a stage.