Additional upgrade scripts for new columns

Valid from Pega Version 7.1.4

In Version 6.2, additional columns (Major, Minor, and Patch) containing ruleset Version information were added to 15 tables in the PRPC database. When upgrading from a pre-Pega 7 release, scripts must be manually run after the upgrade to populate these columns.

These scripts are located in the Resource Kit, under Additional Upgrade Scripts.

  • If upgrading to a single schema, run both scripts.
  • If upgrading to a split schema, run the _data script against the data schema and run the _rules script against the rules schema.
  Depending upon your database type (platform) and the size of your database, these scripts may require significant time and system resources to run.

Choose the scripts for your database type:

  • db2zos_rulesetversion_columns_data.sql
  • db2zos_rulesetversion_columns_rules.sql

 

  • mssql_rulesetversion_columns_data.sql
  • mssql_rulesetversion_columns_rules.sql

 

  • oracle_rulesetversion_columns_data.sql
  • oracle_rulesetversion_columns_rules.sql

 

  • postgres_rulesetversion_columns_data.sql
  • postgres_rulesetversion_columns_rules.sql

 

  • udb_rulesetversion_columns_data.sql
  • udb_rulesetversion_columns_rules.sql

End of support for form-based rule forms in Pega 7.1.9

Valid from Pega Version 7.1.9

Rule forms that are configured to render as forms are no longer supported in Designer Studio or end-user applications. Form-based configurations are found on custom rule types that were created in earlier versions of Pega 7 and are characterized by pop-up windows that are rendered externally from Designer Studio.

Reconfigure Pega 7 applications that use such rule forms by using standard harnesses and sections.

  1. Open the class form.
  2. Click the Advanced tab.
  3. Select Harness from the Rule formmenu.
  4. Create a new harness and new sections that implement the logic of the custom rule, using standard user interface layouts and controls.

Migrating custom rule forms to harnesses and sections offers the following benefits:

  • User interfaces become HTML5 WC3 compatible and responsive to different screen sizes.
  • User interfaces become cross-browser compatible, rendered consistently in Google Chrome, Mozilla Firefox, Apple Safari, and recent versions of Microsoft Internet Explorer.
  • Rendering performance on modern browsers is dramatically improved.
  • User interface pop-up behavior is eliminated; all windows are rendered inside Designer Studio and end-user applications.

End of support for Microsoft Internet Explorer 8 and quirks mode applications in Pega 7.1.9

Valid from Pega Version 7.1.9

In accordance with Microsoft’s announcement to discontinue support for Internet Explorer 8 in January 2016, Pega 7.1.9 does not support Internet Explorer 8, nor does it support non-HTML5 standard user interfaces.

You must upgrade to Microsoft Internet Explorer 9 or later or use Google Chrome, Apple Safari, or Mozilla Firefox. If you are using Internet Explorer 9 or later, you must turn off compatibility mode by accessing the Compatibility View settings.

Note the following:

  • Pega 7.1.9 does not support user interface rules that are not based on HTML5 standards (rules in quirks mode).
  • If you use applications that are rendered in quirks mode, which enables Pega 7 to correctly display and render non-HTML5 standard user interfaces, you must update them to standards-based HTML5 user interfaces when you upgrade to Pega 7.1.9 or later. Pega 7 provides automated tools to help you migrate your applications.
  • Pegasystems Global Customer Support will not investigate or fix any Pega 7.1.9 bugs or support requests that are exclusive to Internet Explorer 8 or quirks mode user interfaces.

You can quickly identify which components of your application user interface are not HTML5 standards-based by clicking Designer Studio > User Interface > HTML5 Application Readiness.

Upgrading to Pega 7.1.9 and a newer browser offers the following benefits:

  • These browsers are HTML5 and CSS3 compliant.
  • New features are supported and existing features work as intended.
  • The Pega 7 Platform user interface is displayed and rendered as intended.
  • Browser security is enhanced.

If you have additional questions about browser support, see the Platform Support Guide or contact Pegasystems Global Customer Support.

Updated default system pulse processing settings

Valid from Pega Version 7.1.9

The default settings for system pulse processing have been updated in this release.

Upgrades to Pega 7.1.9 from a previous version of the Pega 7 Platform use database pulse by default. Database pulse synchronizes rule changes at a periodic interval across all nodes in a system.

New installations of Pega 7.1.9 use cluster-based pulse by default. Cluster-based pulse immediately updates rule changes across all nodes in a system after the changes are saved.

You can change the database pulse setting to the cluster-based pulse setting by updating the value attribute for initialization/pulse/transport to "cluster" in the prconfig.xml file or in the Dynamic System Settings. Changing from database pulse to cluster-based pulse requires a full cluster restart after the changes are made.

For more information, see Pega-RULES agents.

Search field type is deprecated

Valid from Pega Version 7.1.9

The search field type in Form Builder is deprecated. Use a data reference or user reference instead, both of which prompt users with an autocomplete field at run time.

For the full list of supported field types in Form Builder, see Supported display modes by field type.

PegaDISTRIBUTION Manager (PDM) is no longer available

Valid from Pega Version 7.1.9

The PegaDISTRIBUTION Manager (PDM) is no longer available in the Pega 7 Platform. The related PDN articles and help topics have been archived.

Unit testing support for more rule types

Valid from Pega Version 8.3

You can now create unit tests for the following additional rule types. You can also create assertions to validate activity status. The expanded rule types for unit testing enable developers to more thoroughly perform regression testing of their application, thereby improving application quality.

  • Collection
  • Declare expression
  • Map value
  • Report definition

For more information about unit testing rules, see Pega unit test cases.

Upgrade impact

With the four new rule types, unit test execution and unit test compliance metrics will change. Reports on automated unit testing of the customer application decrease due to the increased pool of supported rules.

What steps are required to update the application to be compatible with this change?

After a successful upgrade, create Pega unit test cases for the newly supported rules to see updated and accurate unit test metrics.

Use Page-Change-Class method to change a Page class

Valid from Pega Version 8.3

With the release of Pega Platform™ 8.3, using the Property-Set method to change the Page class shows a guardrail warning. Use the Page-Change-Class method to change the Page class instead.

For more information about the Page-Change-Class method, see Changing the class of a page and Page-Change-Class method.

Cassandra 3.11.3 support for Pega Platform

Valid from Pega Version 8.3

Increase your system's reliability and reduce its memory footprint by upgrading the internal Cassandra database to version 3.11.3.

For on-premises Pega Platform™ users, after you upgrade to Pega 8.3, it is recommended that you manually upgrade to Cassandra 3.11.3. You can upgrade to Cassandra 3.11.3 on all operating systems except IBM AIX. If you do not want to upgrade to Cassandra 3.11.3, you can continue to use Cassandra 2.1.20, which is still supported.

For Pega Cloud Services 2.13 and later versions, Cassandra automatically upgrades to version 3.11.3 after your environment is upgraded to Pega Platform 8.3.

For information on how to manually upgrade to Cassandra 3.11.3, see the Pega Platform 8.3 Upgrade Guide for your server and database at Deploy Pega Platform.

Upgrade impact

After an on-premises Pega Platform upgrade, you still have the older version of Cassandra and must manually upgrade.

What steps are required to update the application to be compatible with this change?

To upgrade Cassandra, you must create a prconfig setting or a dynamic system setting with the new Cassandra version and then do a rolling restart of all the Decision Data Store nodes to upgrade them to the latest version of Cassandra.

 

Support for the decisioning-enabled NLP text analyzer in IVAs and Email Bots

Valid from Pega Version 8.3

You can now use the new intelligent natural language processing (iNLP) text analyzer in Pega Intelligent Virtual Assistants™ (IVAs) and Pega Email Bots™. This advanced text analyzer is decisioning-enabled and empowers IVA or Email Bot for all conversational channels to provide smarter responses. The decisioning capability in the system integrates text analytics with strategies, prepositions, and interaction history, to provide the context for making better next-best-action decisions.

For more information, see Use the decisioning-enabled NLP text analyzer in IVAs and Email Bots, Defining advanced Facebook text analyzer configuration and Facebook channel behavior.

Upgrade impact

Existing channels remain with the current configuration, and their current functionality does not change. Channels created after the upgrade automatically use the new text analyzer.  

What steps are required to update the application to be compatible with this change?

The new text analyzer is enabled or disabled using a new interactive API (iAPI) selection, which is selected by default for new channels. You can disable the iAPI for new channels if you want to maintain current functionality. You can also enable it for existing channels if you want to move existing channels to the new functionality.