Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Additional upgrade scripts for new columns

Valid from Pega Version 7.1.4

In Version 6.2, additional columns (Major, Minor, and Patch) containing ruleset Version information were added to 15 tables in the PRPC database. When upgrading from a pre-Pega 7 release, scripts must be manually run after the upgrade to populate these columns.

These scripts are located in the Resource Kit, under Additional Upgrade Scripts.

  • If upgrading to a single schema, run both scripts.
  • If upgrading to a split schema, run the _data script against the data schema and run the _rules script against the rules schema.
  Depending upon your database type (platform) and the size of your database, these scripts may require significant time and system resources to run.

Choose the scripts for your database type:

  • db2zos_rulesetversion_columns_data.sql
  • db2zos_rulesetversion_columns_rules.sql

 

  • mssql_rulesetversion_columns_data.sql
  • mssql_rulesetversion_columns_rules.sql

 

  • oracle_rulesetversion_columns_data.sql
  • oracle_rulesetversion_columns_rules.sql

 

  • postgres_rulesetversion_columns_data.sql
  • postgres_rulesetversion_columns_rules.sql

 

  • udb_rulesetversion_columns_data.sql
  • udb_rulesetversion_columns_rules.sql

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

Data schema error on z/OS split schema upgrades from versions before Pega 7.1.8

Valid from Pega Version 4.1

When upgrading to a split schema on Pega 7.x with IBM DB2 for z/OS, you see an error during the data schema upgrade when the system tries to drop the PRPC_Updatescache procedure. Because triggers on rules tables use PRPC_Updatescache, you must use the ZOSDisableTriggerScripts to disable these triggers before you update the data schema.

  1. Follow the instructions in the Pega 7 Platform Upgrade Guide to upgrade the rules schema, but stop immediately before you upgrade the data schema with the upgrade.bat or upgrade.sh script. The Pega 7 Platform Upgrade Guide is on the Support > Deployment Guides page.
  2. Copy the contents of the <distribution>\ResourceKit\ZOSDisableTriggerScripts directory into the <distribution>\scripts\ directory.
  3. Run fixZosTriggers.bat or fixZosTriggers.sh with the following arguments:
    --action preupgrade
    --dataschema <data schema name>
    --oldrulesschema <old rules schema name. If you are upgrading from a single-schema system, this is the data schema name.>
    --newrulesschema <new rules schema name>
    --automaticddl <Optional. Set to true to automatically apply the disable trigger SQL scripts.>

    For example:
    fixZosTriggers --action preupgrade --dataschema pegadata --oldrulesschema pegarules --newrulesschema newrules --automaticddl false

  4. If you did not set --automaticddl to true in the previous step, run the <distribution>\schema/disable.sql script to manually disable the trigger SQL scripts.
  5. Run the data schema upgrade as described in the Pega 7 Platform Upgrade Guide.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us