Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Empty properties are not included in snapshot

Valid from Pega Version 7.2.2

History records are smaller and more efficient, because empty properties are no longer included in the snapshot. However, as a result, the history snapshot for sections might present a distorted view of the section.

prpcUtils script fails when the connection property file location is specified

Valid from Pega Version 7.2.2

If you run the prpcUtils command-line script and pass the --connPropFile argument to specify the location of the connection properties file, the script fails with the following error:

Problem: failed to create task or type ac:/antcontrib.org:for

This error does not appear if you do not pass the --connPropFile argument, or if you use the prpcServiceUtils scripts.

As a workaround, edit the prpcUtilsWrapper.xml file:

  1. Open <distribution>\scripts\utils\prpcUtilsWrapper.xml.
  2. Locate the following line:

    <taskdef resource="net/sf/antcontrib/antcontrib.properties" uri="ac:/antcontrib.org">

  3. Replace that line with the following line.

    <taskdef resource="net/sf/antcontrib/antlib.xml" uri="ac:/antcontrib.org">

  4. Save and close the file.

Data schema requires update after multitenant upgrade

Valid from Pega Version 7.2.2

After an out-of-place, multitenant upgrade to Pega 7.2.2 from Pega 7.2 or later, the PR_DATA_TAG_RELEVANTRECORD table that is in the existing data schema is not present in the new rules schema. The table must be present in the rules schema for the upgrade to the rules schema to work. Copy the PR_DATA_TAG_RELEVANTRECORD table from the existing data schema to the new rules schema, and then upgrade the new rules schema. The PR_DATA_TAG_RELEVANTRECORD table is not required to be in the rules schema. After the rules schema upgrade is finished, drop the copy of the table that is in the new rules schema before you upgrade the data schema.

Push notifications and Oracle WebLogic Server 10.3.6

Valid from Pega Version 7.2.2

Pega® Platform push notifications can use WebSockets and long polling. However, for WebLogic Server 10.3.6, the push notifications feature does not work. To disable the feature, contact Pegasystems Global Customer Support.

Load balancing: HTTPD does not support WebSockets by default

Valid from Pega Version 7.2.2

If you use a load balancer with HTTPD (Hypertext Transfer Protocol Daemon), HTTPD does not support fully functional WebSockets and sticky sessions. By default, HTTPD does not support sticky sessions, because if it did, after a session was started, the same server would serve all requests for that session.

Unit testing support for more rule types

Valid from Pega Version 8.3

You can now create unit tests for the following additional rule types. You can also create assertions to validate activity status. The expanded rule types for unit testing enable developers to more thoroughly perform regression testing of their application, thereby improving application quality.

  • Collection
  • Declare expression
  • Map value
  • Report definition

For more information about unit testing rules, see Pega unit test cases.

Upgrade impact

With the four new rule types, unit test execution and unit test compliance metrics will change. Reports on automated unit testing of the customer application decrease due to the increased pool of supported rules.

What steps are required to update the application to be compatible with this change?

After a successful upgrade, create Pega unit test cases for the newly supported rules to see updated and accurate unit test metrics.

Use Page-Change-Class method to change a Page class

Valid from Pega Version 8.3

With the release of Pega Platform™ 8.3, using the Property-Set method to change the Page class shows a guardrail warning. Use the Page-Change-Class method to change the Page class instead.

For more information about the Page-Change-Class method, see Changing the class of a page and Page-Change-Class method.

Data and integration troubleshooting enhancements

Valid from Pega Version 8.3

Identify how data is loaded in user interface (UI) elements, discover the data sources used, and navigate to the relevant rules by using the new Live Data tool. Use the Live Data tool to quickly troubleshoot data and integrations by providing data page information or autopopulate properties from the UI without searching through the clipboard.

For more information, see Troubleshooting data in UI elements.

Retrieve a flat list of fields from Pega Digital Experience APIs

Valid from Pega Version 8.3

You can now use the flatListOfFields parameter to retrieve a list of the fields in a case or flow action. With this parameter, you avoid parsing all the layout information for the Pega Digital Experience API, making it easier for you to see only what you need to build your user interface.

The following Pega Digital Experience APIs support the flatListOfFields parameter:

  • GET /casetypes/{ID}
  • GET /assignments/{ID}/actions/{actionID}
  • GET /cases/{ID}/actions/{actionID}

For more information, see Retrieve a flat list of fields from Pega APIs.

Drag-and-drop functionality for lists and tables

Valid from Pega Version 8.3

Lists and optimized tables now support the reorganization of their content by reordering items. By configuring repeating dynamic layouts and tables to support drag-and-drop modifications, you enable users to move items between lists and within lists and tables. This enhancement ensures that you can create a flexible and dynamic user interface that helps users display and manage data.

The drag-and-drop functionality can also include custom actions that automate the processes that run when users move items.

For more information, see Configuring drag-and-drop functionality for lists and Configuring drag-and-drop functionality for tables.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us