Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Disregard this Java script console message

Valid from Pega Version 7.2.2

Pega 7.2.2 introduced real-time notifications by using Comet technologies such as WebSocket and long polling. WebSocket provides the best results, but both WebSocket and non-blocking long polling must be supported by your application server. If your application server does not support WebSocket, you might see a JavaScript error that begins with text that is similar to the following text:

WebSocket connection to 'ws://vnbamdevapp01:8080/prweb/PRPushServlet/... Error during WebSocket handshake: Unexpected response code: 501_getWebSocket @ pzpega_ui_messaging_1802554968!!.js:1195 pzpega_ui_messaging_1802554968!!.js:3265 Websocket closed, reason: Connection was closed abnormally (that is, with no close frame being sent). - wasClean: falselog @ pzpega_ui_messaging_1802554968!!.js:3265 pzpega_ui_messaging_1802554968!!.js:3265 Websocket failed on first connection attempt. Downgrading to long-polling and resending

You can disregard this message.

However, to take advantage of the improvements to real-time notifications, enable support for WebSocket:

  • For IBM WebSphere Application Server Liberty Core, see your deployment guide for instructions on configuring the application server.
  • For Red Hat JBoss, see your deployment guide for instructions on enabling WebSocket support.
  • For Apache Tomcat application servers, consider upgrading to Apache Tomcat 7.0.53 or later which supports WebSocket.

Empty properties are not included in snapshot

Valid from Pega Version 7.2.2

History records are smaller and more efficient, because empty properties are no longer included in the snapshot. However, as a result, the history snapshot for sections might present a distorted view of the section.

prpcUtils script fails when the connection property file location is specified

Valid from Pega Version 7.2.2

If you run the prpcUtils command-line script and pass the --connPropFile argument to specify the location of the connection properties file, the script fails with the following error:

Problem: failed to create task or type ac:/antcontrib.org:for

This error does not appear if you do not pass the --connPropFile argument, or if you use the prpcServiceUtils scripts.

As a workaround, edit the prpcUtilsWrapper.xml file:

  1. Open <distribution>\scripts\utils\prpcUtilsWrapper.xml.
  2. Locate the following line:

    <taskdef resource="net/sf/antcontrib/antcontrib.properties" uri="ac:/antcontrib.org">

  3. Replace that line with the following line.

    <taskdef resource="net/sf/antcontrib/antlib.xml" uri="ac:/antcontrib.org">

  4. Save and close the file.

Data schema requires update after multitenant upgrade

Valid from Pega Version 7.2.2

After an out-of-place, multitenant upgrade to Pega 7.2.2 from Pega 7.2 or later, the PR_DATA_TAG_RELEVANTRECORD table that is in the existing data schema is not present in the new rules schema. The table must be present in the rules schema for the upgrade to the rules schema to work. Copy the PR_DATA_TAG_RELEVANTRECORD table from the existing data schema to the new rules schema, and then upgrade the new rules schema. The PR_DATA_TAG_RELEVANTRECORD table is not required to be in the rules schema. After the rules schema upgrade is finished, drop the copy of the table that is in the new rules schema before you upgrade the data schema.

Push notifications and Oracle WebLogic Server 10.3.6

Valid from Pega Version 7.2.2

Pega® Platform push notifications can use WebSockets and long polling. However, for WebLogic Server 10.3.6, the push notifications feature does not work. To disable the feature, contact Pegasystems Global Customer Support.

Load balancing: HTTPD does not support WebSockets by default

Valid from Pega Version 7.2.2

If you use a load balancer with HTTPD (Hypertext Transfer Protocol Daemon), HTTPD does not support fully functional WebSockets and sticky sessions. By default, HTTPD does not support sticky sessions, because if it did, after a session was started, the same server would serve all requests for that session.

Semantic URLs in Pega Platform

Valid from Pega Version 8.5

URL addresses for Pega Platform™ applications and application resources now appear as clear, meaningful paths. This enhancement helps users understand the structure of the application that they are using, which makes navigation quicker and more intuitive.

Default views for cases and data objects

Valid from Pega Version 8.5

Pega Platform™ now generates default views for new case types and data objects. Because of this feature, your application now automatically creates a case summary and case details view for every new case type, and a list view for each data object. The default views automate a common recurring task, and improve productivity by reducing development effort.

Improved view authoring

Valid from Pega Version 8.5

Case authoring in Cosmos React UI now features updated view authoring tools. The redesigned view tab and overlay provide a more intuitive interface for creating views, applying design templates, and adding fields and controls. This enhanced work environment improves the user experience and reduces context switching, which contributes to a lower development effort.

For more information, see Editing views in a case type.

Enhanced tables in Cosmos React UI

Valid from Pega Version 8.5

The Pega Platform™ Cosmos React UI environment now includes improved tables. The updated tables use a revamped graphic design and support a number of new run-time behaviors, including column freezing and advanced filtering. The added features improve the user experience by giving case workers more control over data in tables, while the revised architecture enhances efficiency and reliability.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us