Use SAML 2.0 to provide single sign-on authentication

Valid from Pega Version 7.1.6

Configure a SAML 2.0 authentication service to provide web single sign-on (SSO) convenience to product users in your enterprise. A one-click option lets you import Identity Provider (IdP) metadata and make use of automated certificate management.

User interface distortions in the Decision Manager portal

Valid from Pega Version 7.1.6

By default, the New Application wizard in Pega 7.1.6 configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Decision Manager portal. Both applications created in previous maintenance level updates and applications created in Pega 7.1.6 that do not include the UI-Kit-7 dependency are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

User interface distortions in the Predictive Analytics Director portal

Valid from Pega Version 7.1.6

By default, the New Application wizard configures new applications to include UI-Kit-7 in the list of application rulesets. This ruleset causes user interface distortions in the Predictive Analytics Director portal. Applications created in maintenance level updates previous to Pega 7.1.6, and applications that do not include the UI-Kit-7 dependency, are not impacted by this known issue.

Workaround:

  1. Open the application record.
  2. In Application Rulesets, remove UI-Kit-7.
  3. Save the application record.

Add additional columns to customized work history tables

Valid from Pega Version 7.1.6

The standard work history table, pc_history_work, contains two new columns that return the latitude and longitude coordinate location of the action that prompted the history. Mobile devices can display this location as a street address. If you have a customized work history table, add these two columns to it:

  • <decimal name="pxLatitude" size="19" scale="9"/>
  • <decimal name="pxLongitude" size="19" scale="9"/>

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Microsof Internet Explorer 9 (IE9) may display a script error when clicking a Help button

Valid from Pega Version 7.1.6

A script error may be displayed when clicking a Help button when script error notification is turned on in the browser. As a work around, uncheck the Display a notification about every script error option in the Advanced tab of the Options dialog box in Microsoft Internet Explorer 9.

WSDL generation error prevents invocation of SOAP services

Valid from Pega Version 8.4.2

Status

A Known Issue was introduced in the 8.4.2 Pega Platform patch release, which impacts both upgrades and new installations of that version.

Description

Due to changes introduced in the SOAP functionality for the case-mismatch error in SR-D98509/INC-119725, the WSDL is being generated for SOAP services with an incorrectly-capitalized element, which prevents the service from being invoked.  The element should be “name” instead of “Name”.

Workaround

Clients must perform the following workaround after they define a new SOAP connector in Pega Platform:

  1. To download the WSDL from Pega Platform:
    1. After using the SOAP Wizard (Dev Studio > Configure > Integration > Services > Service Wizard) the WSDL URL is shown at the bottom right of the Dev Studio screen.
    2. Click the URL to display the XML.
    3. Save the WSDL file to your local system.
  2. In the text editor of your choice, modify "Name" to "name" in every <element “name” = … > tag in the WDSL.
  3. Save your changes to the local file.
  4. To reload the WSDL into Pega Platform:
    1. In Dev Studio, open the Configure menu.
    2. Select Integration > Connectors > Create SOAP Integration.
    3. In the New SOAP integration wizard, select Upload WSDL from File.
    4. Complete the upload using the wizard prompts.

This is a design-time issue, not a run-time issue; therefore, clients only have to perform this workaround process once. Existing SOAP services should not be impacted; however, if clients modify an existing SOAP service definition by re-running the wizard, clients must reapply the workaround for Pega Platform to recognize the SOAP definition changes.  

Resolution

This issue will be addressed in the Pega Platform Patch Release 8.4.3.  Clients who upgrade to that version or later should not see this issue.

Support for building apps as Android App Bundles

Valid from Pega Version 8.6.1

As of August 2021, Google Play Store requires that you submit new apps in the Android App Bundle publishing format instead of the APK format. You can now build Pega mobile apps in the Android App Bundle format so that they comply with this new requirement.

For more information about generating installation packages for Pega mobile apps, see Generating installation packages. For more information about the Android App Bundle publishing format, see the Android for Developers documentation.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us