Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

System Management

Valid from Pega Version 7.1.4

Refinements were made to out-of-place upgrade documentation and processes, as well as for how handling is performed for all of the database vendor specific nuances related to a deploying into a split schema environment.

  • A script was created to run the data schema upgrade for z/OS systems.
  • In a split-schema configuration, indexing has been enhanced.
  • The product installer has been enhanced.
  • The stand-alone Static Assembly Utility does not require a password for its process.
  • The UpdateManager tool has been improved.

User Interface

Valid from Pega Version 7.1.4

This release had a focus around improving support for accessibility for all the PRPC UI Components as well as extending capabilities for responsive design with grids and tabs. A series of cosmetic changes and fixes are included.

  • Improvements have been made for action items being opened in a dynamic container.
  • Row repeat functionality in sections has been improved to better handle source properties.
  • Screen layouts have been optimized for the iPhone platform
  • The display on dynamic containers has been enhanced to provide the same behavior for both single-mode and multi-mode.
  • The Launch Harness feature has been improved to launch into a pop-up window.
  • The operator menu will now display from the Case Manager portal.
  • The Primary Page functionality has been enhanced for control-defined Repeating Tab Headers.
  • Using local actions defined as modal windows has been enhanced to work in an iPAD using a Safari browser.
  • When using a modal dialog to open a flow action in a repeat grid, to add an item to the list, users may now cancel out of this dialog if no changes are needed.

Upgrade changes system name

Valid from Pega Version 7.1.1

As of Pega 7.1.7, the following renaming behavior no longer occurs.

The upgrade process renames your system to “PRPC” and modifies any custom requestor rules in your application to use this name. After the upgrade completes, you must apply these changes to revert your system:

  1. Identify all custom requestor rules (browser, batch, app, portal) with access groups that point to prior versions of PRPC.
  2. Open the relevant access groups (for example, PRPC:Unauthenticated and PRPC:Agents) and update the name and version fields to point to the current PegaRULES application.
  3. Reset your system name to its original value. You can set the Dynamic System Setting prconfig/identification/systemName/default or use the Designer Studio > System > Settings > System Name landing page.
  4. Restart the system.

Required DB2 settings

Valid from Pega Version 7.1.1

For customers using the DB2 Version 4 drivers (“db2jcc4.jar”), it is necessary to set the custom connection property useJDBC4ColumnNameAndLabelSemantics to “false”.   

For customers using DB2 with WebSphere, the useJDBC4ColumnNameAndLabelSemantics property in the DB2 data source needs to be changed from a Boolean to an Integer and set to "2". 

IE8 limits expansion features

Valid from Pega Version 7.1.1

Internet Explorer 8 (IE8) does not support CSS media queries, which are used by re-expansion features in the Designer Studio. IE8 users with low screen resolution (800 x 600) and a small window size may find that the explorer area in the Designer Studio collapses but cannot re-expand. 

As a work around, access the Designer Studio from another supported browser version and use the recommended, minimum screen resolution width of 1280 pixels.

Limited access for end user portals

Valid from Pega Version 7.1.1

The following portals are only accessible from supported versions of Internet Explorer in “quirks” mode:

  • WorkUser
  • WorkManager

Nesting dynamic containers not supported

Valid from Pega Version 7.1.1

Do not include a section containing a dynamic container inside of another dynamic container. This configuration may cause performance issues resulting in unexpected behavior at runtime, and is not supported.

All tabs are accessible on delegated rule forms

Valid from Pega Version 7.1.1

Delegates can now access all tabs in a delegated rule form.

You can continue to customize the development experience for delegated users, such as line managers, who may not require the full set of rule form options. For example, you can prevent users from adding new nodes on the Decision Tree form or using the expression builder on the Map Value form. All users, including delegated users, can remove these restrictions if they hold a rule-editing privilege.

For more details on this process and a list of commonly delegated rules, see How to delegate a rule.

Using Kerberos authentication with your database

Valid from Pega Version 7.1.1

Pega 7 supports Kerberos functionality. Kerberos is a computer network authentication protocol which allows nodes communicating over a non-secure network to prove their identity to one another in a secure manner. 

 

To use Kerberos for authentication, you must use the command line to install or upgrade Pega 7.

 

To use Kerberos authentication:

1.  Change the setupDatabase.properties file.

a.  In the “Uncomment this property section” of the file, uncomment the jdbc.custom.connection.properties property.  Based on your security infrastructure, different properties may be required as parameters to this property; provide the needed properties as semicolon-delimited name/value pairs:
 

jdbc.custom.connection.properties=prop1=val1;prop2=val2;prop3=val3;
 

Example:  For an installation on a MSSQL database server from a Windows client machine (where both machines belong to the same Windows domain), using the Microsoft JDBC driver, the property may be set as follows:
 

jdbc.custom.connection.properties=integratedSecurity=true;

 

b.  Comment out all the username and password properties where they occur in the jdbc.custom.connection.properties file, so that they appear as follows:


# pega.jdbc.username db username
# pega.jdbc.password db password

[lines removed here]

# pega.jdbc.username=ADMIN
# pega.jdbc.password=ADMIN

 

2.  Set up your database to enable Kerberos functionality.  This may include additional vendor-specific JDBC driver configuration, or other setup procedures.  Check the documentation from your database vendor to determine what Kerberos setup is needed for your database.

 

3.  Run the command line installation or upgrade by following the instructions found in the Pega 7 Deployment guides.

Run cleanup.bat/sh script only before upgrading

Valid from Pega Version 7.1.1

Prior to upgrading the rulebase, you can optionally run the cleanup.bat/sh script to remove older rules from the database.

Run this script before you upgrade your rulebase, or the script may delete needed rulesets. For more information about running the cleanup.bat/sh script, refer to the Upgrade Guide specific to your release version.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us