Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Deprecated end user portals

Valid from Pega Version 7.1.1

The following portals are no longer be supported:

  • SysAdmDD
  • WorkUserDD
  • WorkManagerDD

As a best practice, customize standard, supported portals rather than update your existing portals to include new features.

Run cleanup.bat/sh script only before upgrading

Valid from Pega Version 7.1.1

Prior to upgrading the rulebase, you can optionally run the cleanup.bat/sh script to remove older rules from the database.

Run this script before you upgrade your rulebase, or the script may delete needed rulesets. For more information about running the cleanup.bat/sh script, refer to the Upgrade Guide specific to your release version.

Naming pattern changed for file data sets

Valid from Pega Version 8.6.3

File data sets are used to import from and export data to a file repository. In case of data export, prior to version 8.6.3, the first file exported had the same file name that was provided by the user in the data set, and any subsequent file exported to the repository had a unique identifier appended to it. Starting in Pega Platform version 8.6.3, each file has a unique identifier, automatically generated based on the data flow node, thread ID, and timestamp.

Upgrade impact

If your process to consume output files expects files with a specific name, it may not be able to process the resulting files correctly.

What steps are required to update the application to be compatible with this change?

If you have configured the process before updating to Pega Platform version 8.6.3, but the exported files are no longer recognized by downstream processing logic after the upgrade, ensure that the downstream tool is configured to recognize the files by a pattern rather than the full name. For example, when referring to files exported to the repository, use the * character to indicate a pattern instead of using the full file name. For example, use Export*.csv to refer to the files.

Using Kerberos authentication with your database

Valid from Pega Version 7.1.1

Pega 7 supports Kerberos functionality. Kerberos is a computer network authentication protocol which allows nodes communicating over a non-secure network to prove their identity to one another in a secure manner. 

 

To use Kerberos for authentication, you must use the command line to install or upgrade Pega 7.

 

To use Kerberos authentication:

1.  Change the setupDatabase.properties file.

a.  In the “Uncomment this property section” of the file, uncomment the jdbc.custom.connection.properties property.  Based on your security infrastructure, different properties may be required as parameters to this property; provide the needed properties as semicolon-delimited name/value pairs:
 

jdbc.custom.connection.properties=prop1=val1;prop2=val2;prop3=val3;
 

Example:  For an installation on a MSSQL database server from a Windows client machine (where both machines belong to the same Windows domain), using the Microsoft JDBC driver, the property may be set as follows:
 

jdbc.custom.connection.properties=integratedSecurity=true;

 

b.  Comment out all the username and password properties where they occur in the jdbc.custom.connection.properties file, so that they appear as follows:


# pega.jdbc.username db username
# pega.jdbc.password db password

[lines removed here]

# pega.jdbc.username=ADMIN
# pega.jdbc.password=ADMIN

 

2.  Set up your database to enable Kerberos functionality.  This may include additional vendor-specific JDBC driver configuration, or other setup procedures.  Check the documentation from your database vendor to determine what Kerberos setup is needed for your database.

 

3.  Run the command line installation or upgrade by following the instructions found in the Pega 7 Deployment guides.

Supported JDBC drivers

Valid from Pega Version 7.1.1

Pega 7.1.1 supports Java 6 and Java 7 SDKs only. Ensure that the JDBC driver you are using supports those versions of Java. See your database installation or upgrade documentation for additional information.

DatabaseJava 6Java 7
Oracleojdbc6.jarojdbc7.jar
MSQLsqljdbc4.jarsqljdbc4.jar
DB2 LUWdb2jcc4.jardb2jcc4.jar
DB2 z/OS*db2jcc4.jar or jdb2jcc.jar**db2jcc4.jar
PostgreSQLpostgresql-9.1-903.jdbc4.jar***postgresql-9.1-903.jdbc4.jar

* JDBC drivers are only available from the DB2 for z/OS product. Additionally, you need db2jcc_license_cisuz.jar in the same directory as db2jcc4.jar.

** The db2jcc.jar has been deprecated and may not be supported in future releases.

*** This .jar file is required for PostgreSQL version 9.1.x.

No direct upgrade to multitenant setup

Valid from Pega Version 7.1.1

It is not possible to upgrade directly to a multi-tenant setup. A Pega 7 application may be exported and then imported into a multi-tenant system, with the administrator making the decision as to whether this then becomes a tenant system or a shared system.

 

Applications developed in versions prior to Pega 7 must be upgraded to a Pega 7 standard system, and then exported and imported into a multi-tenant system. See the Multitenancy Administration Guide for full details.

Support for building apps as Android App Bundles

Valid from Pega Version 8.6.1

As of August 2021, Google Play Store requires that you submit new apps in the Android App Bundle publishing format instead of the APK format. You can now build Pega mobile apps in the Android App Bundle format so that they comply with this new requirement.

For more information about generating installation packages for Pega mobile apps, see Generating installation packages. For more information about the Android App Bundle publishing format, see the Android for Developers documentation.

When using Oracle 12.1.0.1, left outer joins in reports may return incorrect results

Valid from Pega Version 7.1.1

When using  Pega 7 with Oracle 12.1.0.1 , reports that use left outer joins may return incorrect results.

This is an Oracle known issue.  To resolve this behavior, upgrade to Oracle 12.1.0.2, apply the Oracle patch 16726638 by requesting it directly from Oracle, or, for Microsoft Windows installations, apply Windows Bundle patch 12.1.0.1.15 or later.

For more information in this behavior, see: https://support.oracle.com/epmos/faces/DocumentDisplay?_afrLoop=392085808201943&id=1957943.1

Upgrade changes system name

Valid from Pega Version 7.1.1

As of Pega 7.1.7, the following renaming behavior no longer occurs.

The upgrade process renames your system to “PRPC” and modifies any custom requestor rules in your application to use this name. After the upgrade completes, you must apply these changes to revert your system:

  1. Identify all custom requestor rules (browser, batch, app, portal) with access groups that point to prior versions of PRPC.
  2. Open the relevant access groups (for example, PRPC:Unauthenticated and PRPC:Agents) and update the name and version fields to point to the current PegaRULES application.
  3. Reset your system name to its original value. You can set the Dynamic System Setting prconfig/identification/systemName/default or use the Designer Studio > System > Settings > System Name landing page.
  4. Restart the system.

Top-level (named) pages may no longer be classless

Valid from Pega Version 7.1.1

Newly created top-level (named) pages may no longer be classless or have a blank pxObjClass property. This change can affect applications upgrading from versions prior to Pega 7 to the latest version, especially when:

  • Application logic relies on a blank value in the pxObjClass property.
  • An activity assumes a new top-level page is classless and explicitly sets pxObjClass in a Property-Set step.
  • A data transform assumes a new top-level page is classless and explicitly sets pxObjClass using a Set action.

To avoid application failures, remove or update any logic that expects a blank pxObjClass. Where possible, use the new engine API that finds a page by both name and class:

findPageWithException(PageName, ClassName);

Activities and data transforms continue to create a top-level page when one does not exist. The class name is now derived from the Pages and Classes tab.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us