INC-193650 · Issue 687904

Corrected focus for changing optimized table density

Resolved in Pega Version 8.7

After selecting an option on the density filter button inside of an optimized table, the focus was set to the top of the browser rather than remaining inside the table layout. This has been resolved.

INC-193775 · Issue 686645

Action Sets in Sections working as expected

Resolved in Pega Version 8.7

When adding actions to a table, the action sets were not always saved correctly. Sometimes actions from one actions set were moved to a new action set without any event, which seemed to occur when there were multiple actions defined for each action set. This was traced to the open of the table property panel in the activity Embed-Harness-SectionBody-Grid.pzGridActionSets activity. This activity sets data for the action set display, including setting a “pyKeyCode” property. The “pyKeyCode” property is not set correctly in certain scenarios, causing the selected action/behavior to not be saved correctly. This has been resolved by changing the local param-pzGridActionSets: TempKeyCode to string.

INC-193861 · Issue 683114

PDF generation corrected

Resolved in Pega Version 8.7

Issues with PDF generation have been resolved by upgrading the PD4ML libraries to version 4.0.9fx5.

INC-193947 · Issue 684137

Focus corrected for dynamic layout in mobile

Resolved in Pega Version 8.7

When any new item was added to a repeating dynamic layout in mobile or if the grid one of the items was expanded, the entire UI refreshed and the focus moved to the top. This has been resolved by adding a check for isMobileFullScreen.

INC-195363 · Issue 690043

Accessibility improvements for Cosmos

Resolved in Pega Version 8.7

After update, some UI changes were seen in Cosmos that could impact accessibility. These included the left panel for the portal can be folded, but the arrow/Icon to fold this pane shows only when you hover over with it with the mouse; on the same portal, Submit and Cancel buttons are displayed at the bottom of the screen as a sticky menu over the long form instead of the previous behavior of being at the bottom of the form; and that the sticky menu partially covered the bottom of the form's functionality. These have been resolved by updating the selectors to make the collapsible icon accessible using keyboard and by removing the sticky behavior for the case action area buttons in the perform harness.

INC-195583 · Issue 684840

Flow action modal pop-up closes after submit

Resolved in Pega Version 8.7

On clicking Submit button on the modal window, the post action was successfully completed but the buttons froze and the modal window did not close. This was traced to a missing condition in the if loop to handle the needed flow action logic, and has been corrected.

INC-197243 · Issue 687412

Locking up+E975dated for EmailLink

Resolved in Pega Version 8.7

After clicking a work link from email and opening the work object in a new window, opening the work object in the perform harness and performing a browser refresh by way of Actions -> Refresh resulted in a locking error when trying to submit the case. This was traced to the handling in the Ajax container: when an assignment is opened from the todo list, it will open it in primary Ajax container. If the complete web page was refreshed, the contents in the Ajax container were cleared and loaded back to previous state. While doing this process the lock of the Work Object was released and not added back. In order to achieve the lock after the refresh, the doUIAction activity has been updated to lock the case when the case is opened and reloaded.

INC-198021 · Issue 686630

Corrected blank areas on maximized view

Resolved in Pega Version 8.7

A blank section was displayed when maximizing the reply screen. Investigation showed that when the editor was inside a positioned container with overflow hidden and the editor had a scrollbar with its body height greater than the document, the scrollIntoView would scroll to grey spaces which were originally hidden by overflow. This has been resolved by commenting out scrollintoview, since it is not necessary and scroll position/cursor will be retained without it.

INC-198484 · Issue 689007

Tab error message localized

Resolved in Pega Version 8.7

Localization has been added for the message that is shown at a tab when a section in tabbed layout contains errors.

INC-199156 · Issue 689742

PDF generation corrected

Resolved in Pega Version 8.7

Issues with PDF generation have been resolved by upgrading the PD4ML libraries to version 4.0.9fx5.