SR-D16427 · Issue 497220

Multi-nodes rebuild LibraryMetadata to ensure all Rule-Utility-Functions are present on change

Resolved in Pega Version 8.3.1

When performing a complete Application import into a clean installation, references to certain Rule-Utility-Functions went unresolved during the initial assembly. Investigation showed that after introducing a new Rule-Utility-Library or Rule-Utility-Function on one node in a cluster and then generating that, the other nodes in the cluster did not have the correct LibraryMetaDataCache for that Rule-Utility-Library. Therefore assemblies on those other nodes could be bad and throw a runtime UnresolvedAssemblyError. This has been resolved by modifying the way the Library subsystem processes the node changes events for Library Generation to ensure that each node completely rebuilds the LibraryMetadata for that Rule-Utility-Library so it contains all the Rule-Utility-Functions.

SR-D32441 · Issue 502572

Multi-nodes rebuild LibraryMetadata to ensure all Rule-Utility-Functions are present on change

Resolved in Pega Version 8.3.1

When performing a complete Application import into a clean installation, references to certain Rule-Utility-Functions went unresolved during the initial assembly. Investigation showed that after introducing a new Rule-Utility-Library or Rule-Utility-Function on one node in a cluster and then generating that, the other nodes in the cluster did not have the correct LibraryMetaDataCache for that Rule-Utility-Library. Therefore assemblies on those other nodes could be bad and throw a runtime UnresolvedAssemblyError. This has been resolved by modifying the way the Library subsystem processes the node changes events for Library Generation to ensure that each node completely rebuilds the LibraryMetadata for that Rule-Utility-Library so it contains all the Rule-Utility-Functions.

SR-D22113 · Issue 498312

Multi-nodes rebuild LibraryMetadata to ensure all Rule-Utility-Functions are present on change

Resolved in Pega Version 8.3.1

When performing a complete Application import into a clean installation, references to certain Rule-Utility-Functions went unresolved during the initial assembly. Investigation showed that after introducing a new Rule-Utility-Library or Rule-Utility-Function on one node in a cluster and then generating that, the other nodes in the cluster did not have the correct LibraryMetaDataCache for that Rule-Utility-Library. Therefore assemblies on those other nodes could be bad and throw a runtime UnresolvedAssemblyError. This has been resolved by modifying the way the Library subsystem processes the node changes events for Library Generation to ensure that each node completely rebuilds the LibraryMetadata for that Rule-Utility-Library so it contains all the Rule-Utility-Functions.

INC-147457 · Issue 621708

Elapsed time in Work History Table includes sub-flow

Resolved in Pega Version 8.4.5

Elapsed times were not captured when an assignment was in a wait shape followed by a utility which set a ticket and moved the assignment to a sub-flow. Investigation showed that when flow execution is in a sub-flow and a ticket is raised, the assignment in sub-flow was removed but audit history was not captured. To handle this scenario, the functions pzCleanSplitForTicket and pzRemoveFlowForTicket have been added, and FlowMethodBody FUA has been modified to include pzCleanSplitForTicket instead of CleanSplit.

INC-149213 · Issue 608519

Email attachments properly displayed in mobile browsers

Resolved in Pega Version 8.4.5

When attempting to use any mobile browser to open the email attachment of a work object, a blank HTML page appeared before the email attachment was shown. The blank page did not appear if the mobile browser was set to use "Desktop mode" or "PC mode". This has been resolved by updating the BAC registration method so that correspondence attachments are properly opened in all mobile browsers and HC apps for all channel types. An additional issue of a blank window appearing on IOS devices that was caused by correspondence attachments opening in a new window instead of opening in the current window has also been corrected.

INC-153801 · Issue 625945

Modified handling for updating SLA on Bulk Agent items

Resolved in Pega Version 8.4.5

While transferring SLA-configured assignments to the work basket using the Bulk Agent in background processing, the assignment handle of the SLA item was not getting updated to the work basket assignment handle. The error "duplicate key value violates unique constraint" was logged. This was due to the system not being able to dequeue the SLA item while it was locked by the Queue Manager as part of the background bulk processing, preventing the assignment handle from being updated on the SLA item. To resolve this, the system will perform a direct database open of the SLA item so the assignment handle is updated.

INC-154778 · Issue 620905

Bulk actions filtering works in Spanish locale

Resolved in Pega Version 8.4.5

Filtering by only case type did not return any results when using the Bulk Transfer functionality with the Spanish locale. Investigation showed that the filter value case type had a field value set, but the localized value was not being checked in the pzPostFilterOperation in step 1 'when' condition. This has been resolved.

INC-159334 · Issue 626762

Handling added for custom attachment method

Resolved in Pega Version 8.4.5

When sending a correspondence using the standard SendSimpleEmail activity, choosing only one attachment from the multiple attachments in the work object by passing the pxLinkedRefTo property from the clipboard page to the AttachmentKeysToSend parameter instead of passing the value to the AttachmentCategoriesToSend parameter successfully sent the message and attached it to the work object. However, opening the correspondence attached to the work object showed the attached file as blank even though the attachment was present in the receiver’s email. Research showed that during the comparison of keys in place of pxLinkedRefTo, pzinskey was used. This caused the comparison to not register as true and the attachments display was skipped. This has been resolved by updating the Data-Corr-Email.Show Html rule to use the pxLinkedRefTo field to find the right attachment. The URL encryption was also updated to ensure the links are functional and attachments can be downloaded.

INC-159624 · Issue 626187

Check added to set class for inheritance if Work- is not present

Resolved in Pega Version 8.4.5

Bulk Action transfer was not working for Assignments from Data class. Investigation showed that when the interest page class inheritance did not contain Work-, flow action pyTransferAssignment was not able to render as it is present in Work- layer. To resolve this, a check has been added to the pyGetRelevantActions so that if the interest page class inheritance doesn't contain Work-, the case class will be set from the workobj page.

INC-160078 · Issue 628838

Work object status correctly set to Resolved after refresh

Resolved in Pega Version 8.4.5

When using the Refresh option from the Other Actions menu before submitting the flow action, the work object status was not updating to Resolved-Completed. Investigation showed that when performing the Refresh action, the RefreshOnConflicts activity created a Clipboard page named LatestWorkPage with a copy of the work object. This page was not removed after use, causing the Resolved-Completed status to be set on LatestWorkPage instead of pyWorkPage. To resolve this, a step has been added to RefreshOnConflicts to remove LatestWorkPage.