SR-117345 · Issue 179910
"Edit in Excel" handling corrected for delegated decision tables
Resolved in Pega Version 7.1.8
"Edit in Excel" was not working correctly on a decision table if it was delegated to a WorkManager portal from a traditional portal. After clicking on the edit button two pop ups appeared, and the Excel sheet was not visible after the pop ups were dismissed. This was traced to an issue with ActiveX where the server was not getting a fully-qualified URL in cases of open portal threads, and a check has been added to ensure proper handling.
SR-117827 · Issue 186000
Improved condition handling for complex harnesses
Resolved in Pega Version 7.1.8
If a Review Harness had multiple embedded tab sections with includes, a read-only condition in the parent section was not being honored in a sub-section if the 'when' condition became false. This happened when a SectionIncludeInCell RUF passed an unquoted null value as a 3rd argument while invoking stream reference, and has been resolved.
SR-117827 · Issue 183888
Improved condition handling for complex harnesses
Resolved in Pega Version 7.1.8
If a Review Harness had multiple embedded tab sections with includes, a read-only condition in the parent section was not being honored in a sub-section if the 'when' condition became false. This happened when a SectionIncludeInCell RUF passed an unquoted null value as a 3rd argument while invoking stream reference, and has been resolved.
SR-117877 · Issue 178627
Report on implementation classes corrected for descendant class
Resolved in Pega Version 7.1.8
Report definition was not using implementation class even when 'report on descendant class' was checked. This was caused by an access group changed in RAQ not being reflected into DAQ. When a Data-Admin-Requestor has a Access group which isn't the default, the default authentication doesn't occur and as such the application data page isn't created for the requestor. The lack of an application page causes the code to not determine the associated implementation class for the report definition. This has been changed to use the access group from DAQ only if it is newer than RAQ.
SR-117877 · Issue 175972
Report on implementation classes corrected for descendant class
Resolved in Pega Version 7.1.8
Report definition was not using implementation class even when 'report on descendant class' was checked. This was caused by an access group changed in RAQ not being reflected into DAQ. When a Data-Admin-Requestor has a Access group which isn't the default, the default authentication doesn't occur and as such the application data page isn't created for the requestor. The lack of an application page causes the code to not determine the associated implementation class for the report definition. This has been changed to use the access group from DAQ only if it is newer than RAQ.
SR-117931 · Issue 181714
Resolved clipboard conflict for obj-open-by-handle
Resolved in Pega Version 7.1.8
Doing an obj-open-by-handle or obj-open-by-handle/copy on work objects containing properties that reference data pages caused errors about non modifiable pxObjClass properties and non matching clipboard property modes. This was caused by a clipboard conflict, and has been addressed by handling the clipboard property as set value for feature property.
SR-118044 · Issue 178369
Corrections and enhancements made to Outlook meeting requests
Resolved in Pega Version 7.1.8
Using the function 'SendEmailMessage' to send an Outlook meeting request was only generating an email instead of the full meeting invitation. This was traced to unimplemented code and has been corrected. In addition, enhancements have been added to the FormatMeetingRequest RUD to set RSVP options for TO & CC recipients, and the PRODID flag value has been parameterized.
SR-118160 · Issue 175398
Email Listener performance improved
Resolved in Pega Version 7.1.8
A mismatch in time values was causing Email Listener to be extremely slow in some complex installations. This has been corrected to improve performance.
SR-118213 · Issue 184519
Refresh When' behavior fixed for portal tabs
Resolved in Pega Version 7.1.8
When a 'Refresh When' was active on a portal tab, the system would become unresponsive while trying to refresh it. This was caused by an incorrect element call resulting in a JavaScript error and has been corrected.
SR-118224 · Issue 182305
Report Definition "Pick Value" list resolves to correct layer
Resolved in Pega Version 7.1.8
When a report definition in the framework layer has "Report on descendant class instances" checked, running the report from the implementation layer should retrieve pick list values for "Available Values" on filter popup from the implementation layer. Instead, it was getting the values from the framework layer. This was caused by the code that generates the SQL query to populate the "Pick Value" list resolving to the wrong work class name, using the framework layer work class rather than the implementation layer work class. There was a workaround of performing a 'Save As' of the affected reports to each implementation layer, but this has been fixed.