INC-180233 · Issue 660579

Offline.Rulecache UI module capacity increased

Resolved in Pega Version 8.6.1

Clicking the save button on a modal window caused the application to freeze and all the buttons were disabled. This was traced to the pega.offline.rulecache UI module having a default hard limit of 500 rules. Once the hard limit was reached, the system intermittently silently refused caching additional rules depending on the amount of rules packaged or the order in which the rules are loaded to the cache. To resolve this, the system has been updated to only log a console warning once the maximum threshold is reached, allowing the application to operate normally and at the time inform about the potential impact of having too many rules in memory.

INC-151293 · Issue 630347

Out of memory condition resolved for BIX extraction

Resolved in Pega Version 8.6.1

A node was going down automatically during execution of a BIX Extract rule when working with old objects. Investigation showed this was related to an out of memory error: the work object had nested page lists, and when one of the page lists contained a propertylist which contained more records, the system was trying to add entries to the LinkedList if any properties were missing the reference during extraction. Because LinkedList allowed duplicates, it filled with enough errors to cause the out of memory condition. To resolve this, LinkedList has been replaced with LinkedHasSet, which does not allow duplicates.

INC-160190 · Issue 658126

Logic updated to allow page property and declare index with the same name

Resolved in Pega Version 8.6.1

A Property which was in a page list which in turn was embedded in a Page was not visible in the Report Browser. This was traced to the two properties sharing the same name, and was caused by a check which ensured only entries with unique names were added. In order to support this configuration, logic has been added to pzAddPropListForClass_TreeGrid such that if a page property and declare index share the same name, they are both added to the tree grid.

INC-160608 · Issue 648636

Added handling for missing deleted/report shortcut for drilldown

Resolved in Pega Version 8.6.1

Whenever “Report Details” for a drilldown report without category was clicked, a Flow Action Error was generated. This was due to a missing Report shortcut normally stored in the Report Definition, and has been resolved by modifying pzPreProcessReportDetails to handle the edge case of a shortcut not present/deleted for a drill-down report.

INC-162649 · Issue 639398

DSS added for handling missing attachments

Resolved in Pega Version 8.6.1

When an S3 repository was configured as storage, some cases were not coming up in search and exception errors were seen in logs for a deleted attachment after every system restart/re-indexing of the search. Investigation showed these case objects were in the broken queue for pyFTSIncrementalIndexer due to a null pointer error encountered when indexing the attachment, and that the attachments were available in the repository but could not be read from the attachment repository during indexing. To resolve this, a new DSS setting has been added which allows selecting one of two behaviors: - Pega-SearchEngine indexing/distributed/fail_on_missing_attachment_file = true : broken item is generated, but with a meaningful error message. This is the default behavior - Pega-SearchEngine indexing/distributed/fail_on_missing_attachment_file = false: case is indexed, but without the problematic attachment. Error message is printed out to the logs.

INC-166120 · Issue 657057

Parameter added to prevent name localization in Dev Studio Reports

Resolved in Pega Version 8.6.1

Running the DataTableEditorReport against a customer table translated names that matched localized values, such as "Mr. Block" became "Mr. Sperren" when the locale was set to de_DE even though the property was marked as "Do not localize" in UI Controls in the report definition filter. To resolve this, the parameter 'pyskiplocalization' has been added for use in the RRFilters_logic and while displaying the select Values popup.

INC-168203 · Issue 641337

Improved performance for data flow runs

Resolved in Pega Version 8.6.1

Nodes were intermittently going into safe mode after a service registry heartbeat failure. Investigation found that some of the activities were performing an Obj-Browse that invoked report definition logic to call the database classmap. This has been resolved by modifying the implementation for the initialization and caching of list of classes in a table.

INC-169055 · Issue 646674

Performance improvements for database queries and archiving

Resolved in Pega Version 8.6.1

In order to improve the performance of database queries, repetitive unnecessary database calls have been removed, archival queries have been simplified, and diagnostic metrics were added. Optional batch requestors have been added to all archival services with their own DSS settings to allow processing more cases in parallel. It is recommended to create 2 additional indexes to help with the archival process. The indexes will be on:pegadata.pr_metadata (pyisparent, pyobjclass, pyarchivestatus) INCLUDE (pyinskey); pegadata.pr_metadata (pyisparent, pyarchivestatus) INCLUDE (pyinskey);

INC-169856 · Issue 649460

Personalized table sort order limited

Resolved in Pega Version 8.6.1

After implementing a personalized table, the query started adding more 'order by' sorts, causing system impact. This was traced to the pzPopulateSortOrder activity Implementation having different constants assumed for the same purpose (999 in one place and 99999 in another), and has been resolved by updating the logic in step 1 and step 2 to disregard sort orders higher than 999.

INC-170389 · Issue 645001

Updated authentication for report filter screen

Resolved in Pega Version 8.6.1

If the report filter screen was shown first after clicking on the report link in the report browser, an error is generated for users but not for administrators. This has been resolved by registering the activity and adding a BAC registration section to the prompt filter section.