SR-C95840 · Issue 434789
Independent query logic inserted for non-resolved rules to avoid non-applicable columns
Resolved in Pega Version 8.3
Nothing was displayed under "Revalidate and save" for Rule-Ruleset-Name and Rule-Ruleset-Version. In Tracer there was an error message saying that "There was a problem getting a list: code: 207 SQLState: S0001 Message: Invalid column name 'pyRuleAvailable'. " Investigation showed that because the system was using the same logic for resolved and non-resolved rules, Rule-Ruleset-Name and Rule-Ruleset-Version were looking for the column pyRuleAvailable which was not applicable because non-resolved rules don't have this column. To resolve this issue, a separate query executor has been added for non-resolved rules as there are a few columns related to resolved rules that are not applicable for those that are not resolved.
SR-D13 · Issue 434981
Memory leak repaired
Resolved in Pega Version 8.3
A server side memory leak was traced to heap utilization increasing due to a Stream control assembly problem where the CleanForReuse() function was not cleaning up pzAuto. The cleanForReuse method in generated HTML properties is used to either initialize local fields, in which case aContext will be non-null, or to clear the object for pooling, in which case aContext will be null. Because the pzAuto variable was not being properly nullified, pooled controls were retaining stale references to StreamTools, LayoutRuntime, PRThread, and others. This has been resolved by adding code to ensure the pzAuto variable is correctly nullified.
SR-C79540 · Issue 435150
Corrected report harness popup display in frameless portal
Resolved in Pega Version 8.3
After configuring the pyCMReportBrowser7 Harness in the Application Menu and executing the report, clicking on the Drill down report displayed the report on the Main work area and Application Header,Footer, Menu. This happened only when a report with custom filters was loaded on a no-frame portal like caseworker, and was traced to portal chrome(header/sidepanel/footer) being added to every harness in no-frame portals to handle top navigation for every desktop action. In this case, when a report filter was opened in popup, the target parameter that held the "popup" value was lost by the time the submit button was clicked on filter window. To resolve this, a new property pyReportTarget has been added will use the target parameter value in the pzValidateCustomFilterSection activity.
SR-C96571 · Issue 435174
Added check for visible SmartInfo so focus is maintained
Resolved in Pega Version 8.3
After setting up a harness that displayed page-level messages at the top and bottom with "info" icons in a grid that displayed SmartInfo, hovering on one of the "info" icons when a page-level message was displayed caused the page to scroll up to the page-level message at the top of the harness instead of displaying the SmartInfo popup. This has been resolved with the addition of a check for visible SmartInfo in pzpega_ui_doc_errors.js so the focus is properly set.
SR-C97610 · Issue 435222
Enhanced backwards compatibility for Attachment Gadget
Resolved in Pega Version 8.3
After upgrade, information was missing from Attachments. This included the case number being absent from between the parentheses on the Attachment name; the time stamp was missing on the attachment; and checking the 'Show Subcase Attachments' checkbox did not provide the expected information for the attachment. This was traced to a reworking of the attachment gadget in Pega 7.1.5, and logic modifications have now been added to enhance backwards compatibility with the 6.x versions of Pega.
SR-C93726 · Issue 435285
Work status icons work correctly when using localization
Resolved in Pega Version 8.3
The pyWorkAssignmentStatus control was not displaying the status flags/icons for localized work status values due to a match failure caused by the system using the localized text for the pyAssignmentStatus to perform a string comparison against the hard-coded English values. To correct this, the control pyWorkAssignmentStatus has been modified to run the comparisons with the new string "assignmentStatus" instead of with the localized text.
SR-D114 · Issue 435312
Grid menu dropdown properly hidden while editing filter
Resolved in Pega Version 8.3
After opening the filter options as if to change the filter, summarizing any of the available columns without closing the filter resulted in a screen showing a broken filter. This was traced to the implementation of the navigation menu for auto-generated grids, which was not allowing other functions while any of the "inline modals" are being used, such as editing a filter. To correct this, the grid menu dropdown will not be shown while editing a filter. This is consistent with the rest of the UI actions which are hidden while editing a filter.
SR-C91898 · Issue 435421
Resolved Rich Text Editor display in popup windows
Resolved in Pega Version 8.3
The Rich text editor was not displaying in popup windows although it did display otherwise. Investigation traced this to the harness context APIs used in "pega.contro.IRTE.init" (pzpega_control_richtexteditor.js rule) returning rteTextArea as null, leading to the RTE scripts failing to bind the ckeditor dom. This has been fixed by replacing the harness context APIs with ones better suited to this use.
SR-C94190 · Issue 435433
Fixed Export to PDF page formatting
Resolved in Pega Version 8.3
A formatting issue was seen when using export to PDF; the first page contained only the title of the report as well as the filter, the generated date, and the number of records, and the exported data was included only from the 2nd page onwards. This has been corrected, and some performance improvements for the generation time were added.
SR-D520 · Issue 435485
Wait corrected for sub case after reopening
Resolved in Pega Version 8.3
A re-opened parent case was not waiting for the sub case when a sub case was reopened, but it did wait if there was no sub case on the reopened parent case. This has been resolved by enhancing the system to better handle the reopen of activator and dependent work objects by checking the reopen time: - pzGetAllStatusforDepClass activity: added step 2 to consider activator reopen time - pzGetMessageKeysForFlowDependencies list view: added criteria to filter on reopen time