INC-118838 · Issue 560691
OKTA receives parameters on logout
Resolved in Pega Version 8.2.7
When using an OIDC logout endpoint with a parameter set as a data page value, the data page retrieved the ID Token from the DB, but when logout was clicked the datapage name was being displayed in the browser instead of the IDToken. To resolve this, code has been added to support sending ID token parameters for logoff endpoint for OKTA logoff using OpeniD connect.
SR-D95148 · Issue 557483
Port validation updated for redirect URI
Resolved in Pega Version 8.2.7
When an offline app for windows client was generated, trying to login via SSO resulted in the error "invalid redirect_uri". This was traced to the system validating the whole loopback redirection URL, e.g. "http://127.0.0.1:1234/redirection", including the port number. To enhance flexibility, an update has been made so that the port number will not be validated, allowing the client to establish it based on availability at the moment of the request to the authorization service. NOTE: As a best practice, a loopback URL should not be configured as a redirect URI. If a loopback URL is configured, then at run time the port number will not be validated, and the client application can use any available port on the system including ports that may not be intended for use.